Nusiwo li: | |
---|---|
Agbɔsɔsɔme: | |
DFPA409-100 C6 / DFPA512-100 C6 / DFPA409-100C1 / DFPA512-100 C1.
DFUN .
-High-rate Battery Cells (Standard): Eɖo nudidi si nye be woawɔ ɣeyiɣi kpui aɖe ƒe megbeŋusẽ si nye miniti 10-60 la gbɔ.
-sɔ na UPS dɔwɔwɔwo kple kple neutral wire.
-LifePo4 lãmenugbagbeviwo ƒe agbenɔƒe: ≥2500 tsatsam le 1C charge/discharge rate, ≥1500 cycles le 4C discharge/0.5c charge rate.
-Triple automatic protection: doa alɔ takpɔkpɔ le positive kple negative electrodes kple circuit breaker, si naa kakaɖedzi batri ƒe kakaɖedzi.
-Dzotsi te (si sɔ) kple dzotsitsi le kabinet ƒe ɖoɖo nu (woate ŋu atiae) hena dzo ƒe tete ɖe anyi si sɔ pɛpɛpɛ kple esi le dzo dam kabakaba.
-Auto-Start Function: Enaa dɔwɔwɔ si me ame aɖeke mele o wɔa dɔ to ŋusẽ gbugbɔgaɖoanyi megbe le eɖokui si.
-Ewɔ Smart-LI Battery Monitoring Cloud Platform: Ekpɔa egbɔ be dɔwɔwɔ kple beléle nyuie le dedie eye wònyo, si ɖea gbesiagbe dɔwɔwɔ ƒe gazazãwo dzi kpɔtɔna.
-Modular Design: Enaa ɖoɖo bɔbɔe kple ɖoɖo kabakaba; Maximum of 6 cabinets le parallel, na na flexible backup time tiatia.
Mᴐbibia |
Ɣeyiɣi kpui aɖe ƒe backup power≥10 miniti . |
Ɣeyiɣi didi ƒe megbeŋusẽ ≥60 miniti . |
||
Li-Ion batri ƒe ɖoɖo ƒe kpɔɖeŋu . |
DFPA409-100 C6. |
DFPA512-100 C6. |
DFPA409-100C1. |
DFPA512-100 C1. |
Ŋutete na UPS ɖoɖo . |
20-240kva . |
20-300kva . |
20-40kva . |
20-50kva . |
Rated Output Voltage (V) . |
409.6V . |
512V . |
409.6V . |
512V . |
Batri ƒe module ƒe kpɔɖeŋu . |
51.2V100AH-6C . |
51.2V100AH-1C . |
||
Batri ƒe Modules ƒe xexlẽme (PCS) . |
8pcs . |
10pcs . |
8pcs . |
10pcs . |
Batriki ƒe ƒuƒoƒo ƒe ŋutete (AH) . |
100Ah . |
100Ah . |
||
Batri ƒe Ƒuƒoƒo ƒe Ŋusẽ (KWH) . |
40.96kWh . |
51.2kWh . |
40.96kWh . |
51.2kWh . |
Max. Batriki ƒe ɣeyiɣi si me woɖea dzo le ɣesiaɣi . |
600A . |
100A . |
||
Max. ƒe ŋusẽ si dona le eme (KW) . |
240kW . |
300kW . |
40kW . |
50kW . |
Equalizing charge voltage (v) . |
441.6V . |
552V . |
441.6V . |
552V . |
Floating charge voltage (v) . |
435.2V . |
544V . |
435.2V . |
544V . |
Cut-off ƒe dzoxɔxɔ si dona le eme (V) . |
352V . |
440V . |
352V . |
440V . |
Kadodo ƒe ƒomedodo . |
CAN/RS485/Dry Kadodo . |
|||
Takpɔkpɔ . |
Woxɔa ga geɖe wu, woɖea asi le nu ŋu wògbɔa eme, dzoxɔxɔ si gbɔ eme, si sɔ gbɔ wu, nutomeyimɔ̃ kpuiwo, kple bubuawo. |
|||
didime (LXWXH) . |
600-1000-2000mm . |
|||
Kpekpeme |
Module kpekpeme xn + kabinet kpekpeme200 . |
|||
Dzoxɔxɔ si le dɔ wɔm . |
0-40 ° C (wokafu 20-25 °C) |
-High-rate Battery Cells (Standard): Eɖo nudidi si nye be woawɔ ɣeyiɣi kpui aɖe ƒe megbeŋusẽ si nye miniti 10-60 la gbɔ.
-sɔ na UPS dɔwɔwɔwo kple kple neutral wire.
-LifePo4 lãmenugbagbeviwo ƒe agbenɔƒe: ≥2500 tsatsam le 1C charge/discharge rate, ≥1500 cycles le 4C discharge/0.5c charge rate.
-Triple automatic protection: doa alɔ takpɔkpɔ le positive kple negative electrodes kple circuit breaker, si naa kakaɖedzi batri ƒe kakaɖedzi.
-Dzotsi te (si sɔ) kple dzotsitsi le kabinet ƒe ɖoɖo nu (woate ŋu atiae) hena dzo ƒe tete ɖe anyi si sɔ pɛpɛpɛ kple esi le dzo dam kabakaba.
-Auto-Start Function: Enaa dɔwɔwɔ si me ame aɖeke mele o wɔa dɔ to ŋusẽ gbugbɔgaɖoanyi megbe le eɖokui si.
-Ewɔ Smart-LI Battery Monitoring Cloud Platform: Ekpɔa egbɔ be dɔwɔwɔ kple beléle nyuie le dedie eye wònyo, si ɖea gbesiagbe dɔwɔwɔ ƒe gazazãwo dzi kpɔtɔna.
-Modular Design: Enaa ɖoɖo bɔbɔe kple ɖoɖo kabakaba; Maximum of 6 cabinets le parallel, na na flexible backup time tiatia.
Mᴐbibia |
Ɣeyiɣi kpui aɖe ƒe backup power≥10 miniti . |
Ɣeyiɣi didi ƒe megbeŋusẽ ≥60 miniti . |
||
Li-Ion batri ƒe ɖoɖo ƒe kpɔɖeŋu . |
DFPA409-100 C6. |
DFPA512-100 C6. |
DFPA409-100C1. |
DFPA512-100 C1. |
Ŋutete na UPS ɖoɖo . |
20-240kva . |
20-300kva . |
20-40kva . |
20-50kva . |
Rated Output Voltage (V) . |
409.6V . |
512V . |
409.6V . |
512V . |
Batri ƒe module ƒe kpɔɖeŋu . |
51.2V100AH-6C . |
51.2V100AH-1C . |
||
Batri ƒe Modules ƒe xexlẽme (PCS) . |
8pcs . |
10pcs . |
8pcs . |
10pcs . |
Batriki ƒe ƒuƒoƒo ƒe ŋutete (AH) . |
100Ah . |
100Ah . |
||
Batri ƒe Ƒuƒoƒo ƒe Ŋusẽ (KWH) . |
40.96kWh . |
51.2kWh . |
40.96kWh . |
51.2kWh . |
Max. Batriki ƒe ɣeyiɣi si me woɖea dzo le ɣesiaɣi . |
600A . |
100A . |
||
Max. ƒe ŋusẽ si dona le eme (KW) . |
240kW . |
300kW . |
40kW . |
50kW . |
Equalizing charge voltage (v) . |
441.6V . |
552V . |
441.6V . |
552V . |
Floating charge voltage (v) . |
435.2V . |
544V . |
435.2V . |
544V . |
Cut-off ƒe dzoxɔxɔ si dona le eme (V) . |
352V . |
440V . |
352V . |
440V . |
Kadodo ƒe ƒomedodo . |
CAN/RS485/Dry Kadodo . |
|||
Takpɔkpɔ . |
Woxɔa ga geɖe wu, woɖea asi le nu ŋu wògbɔa eme, dzoxɔxɔ si gbɔ eme, si sɔ gbɔ wu, nutomeyimɔ̃ kpuiwo, kple bubuawo. |
|||
didime (LXWXH) . |
600-1000-2000mm . |
|||
Kpekpeme |
Module kpekpeme xn + kabinet kpekpeme200 . |
|||
Dzoxɔxɔ si le dɔ wɔm . |
0-40 ° C (wokafu 20-25 °C) |