Aƒeme » Nusiwo Wowɔ » Ŋusẽdzidzenu » DC Ŋusẽdzidzenu » DFPM207L Multi-Loop DC Ŋusẽdzidzenu

agbatsɔtsɔ

DFPM207L Multi-Loop DC Ŋusẽ Mita

Wotrɔ asi le DFPM207L ŋu na 48V DC ɖoɖowo le server xɔwo kple nyatakakadzraɖoƒewo, mita sia si dea pɛpɛpɛ ŋutɔ naa ŋusẽ ŋuti nyatakakawo nuƒoƒoƒu bliboe le mama ƒe nuwuƒewo (le kpɔɖeŋu me, bɔsmɔ ƒe kabinetwo), si wɔnɛ be woate ŋu akpɔ ŋusẽ le ɣeyiɣi ŋutɔŋutɔ me eye woawɔ ŋusẽzazã nyuie wu.
Nusiwo Li:
Agbɔsɔsɔ:
facebook dzi mamã ƒe dzesi
twitter dzi mamã ƒe dzesi
fliwo mama ƒe dzesi
wechat mama ƒe dzesi
linkedin ƒe mama ƒe dzesi
pinterest mama ƒe dzesi
whatsapp ƒe mamã ƒe dzesi
sharethis mamã ƒe dzesi
  • DFPM207L ƒe ƒuƒoƒo

  • DFUN ƒe nyawo

Adzɔnuwo Ŋuti Nyatakaka

Wotrɔ asi le eŋu na DC ɖoɖo 48 le server xɔwo kple nyatakakadzraɖoƒewo, mita sia si de pɛpɛpɛ ŋutɔ naa ŋusẽ ŋuti nyatakakawo nuƒoƒoƒu bliboe le mama ƒe nuwuƒewo (le kpɔɖeŋu me, bɔsmɔ ƒe kabinetwo, si wɔnɛ be woate ŋu akpɔ ŋusẽ dzi le ɣeyiɣi ŋutɔŋutɔ me eye woawɔ ŋusẽzazã nyuie wu.

Voltage Kpekpeɖeŋu: DC 48V ɖoɖowo

> Nutome Gã Takpekpea ƒe Tiatiawɔblɔɖe:

1) 1 alo 2 dede mɔwo (elektrik parameter dzidzedze blibo) .

2) Hall Sensors (Input): 400A/600A/800A/1600A (woate ŋu atia)

3)10:8xDI, 2/4xDO ƒe xexlẽme

4) Tiatia dzoxɔxɔ / fafa sensor (+0.5 ° C nyateƒetoto)

> Alɔdzedɔwɔƒea ƒe Nutome Gã Takpekpewo:

1) Dzidzea fifia / ŋusẽ na Max.144 alɔdze nutome suewo

2) Hall Sensors (Dodo): 50A/100A/200A

3) 144xDI na nɔnɔme ŋuti nyaŋuɖoɖo.

> Ðoɖowo: Modbus-RTU/TCP

> Kadodo & Dɔwɔƒe ƒe Ʋudzeƒewo : 1xRJ45, 2xRS485 (RS485-1 na amedzroxɔla, RS485-2 na HMI)

> Ðoɖowo: Modbus-RTU/TCP

nɔnɔmetata.png

Adzɔnuwo ƒe Ŋgɔdonya

> Dɔwɔƒe si Kpɔa Mɔ Siwo Gbɔna Dzi: DFPM207L-M-1/2

- Dzidzenu Ŋutetewo Input Channels: 1 alo 2 fli siwo va (woate ŋu atia) .

- Rated Voltage: DC48V ɖoɖowo

- Ɖoɖonunɔnɔ:

1) Voltage / Fifia: Klass 0.5 (+0.5%) .

2) Ŋusẽ/Ŋusẽ: Klass 1 (+1.0%) .

- I / O: 8 x DI / 2 x DO (M2) / 4 x DO (M1) .

- Nutome Dzi Kpɔkpɔ:

1) Dzoxɔxɔ ƒe didime: -20°C va ɖo +80°C (+0.5°C @25°C)

2) Fafa ƒe didime: 0-100% RH (+5% RH)

- Kadododzikpɔƒewo:

1) Uplink: 1xRJ45 + 2xRS485 (RS485-1 na amedzroxɔla, RS485-2 na HMI)

2) Downlink: BUS1 / BUS2 (daisy-kɔsɔkɔsɔ si sɔ)

- Ðoɖowɔɖi ƒe Kpekpeɖeŋu: Modbus-RTU/TCP

- Ŋusẽ & Dɔwɔɖoɖo Kpekpeɖeŋu Ŋusẽ: DC± 12V (± 10% mɔɖeɖe)

Nusiwo woatsɔ aɖoe: DIN ketekemɔ si wozãna ɖaa

wotsɔ-nɔnɔmetata- 17872058532 13.png
nɔnɔmetata.png

Si do ŋgᴐ: 
Esi kplᴐe ɖo: 
Te Ðe Mía Ŋu
Do Ka Kple Mía

Adzɔnuwo ƒe Ƒomedodo

Kadodo Kabakabawo

Te Ðe Mía Ŋu

 ƒe xexlẽme  info@dfuntech.com
   +86- 15919182362
  +86-756-6123188 ƒe xexlẽdzesiwo

Nutata ƒe Gomenɔamesi © 2023 DFUN (ZHUHAI) CO., LTD. Gomenɔamesiwo katã le esi. Ameŋunyatakakawo Ŋuti Ðoɖo | Nyatakakadzraɖoƒe ƒe Nɔnɔmetata