
Kodi Battery Monitoring System (BMS) ndi chiyani?
A Battery Monitoring System (BMS) ndi nsanja yanzeru yomwe idapangidwa kuti izingoyang'anira, kusanthula, ndi kuteteza makina a batri omwe amagwiritsidwa ntchito m'malo ovuta kwambiri. BMS yapamwamba kwambiri ya DFUN Battery Monitoring System imayang'anira magwiridwe antchito a batri munthawi yeniyeni pazingwe zonse komanso mulingo wa cell pawokha, kuthandiza mabungwe kuti aletse kulephera, kukulitsa moyo wa batri, ndikusunga mphamvu zodalirika.
Dongosolo limayesa magawo ofunikira monga magetsi, zamakono, kutentha, kukana kwamkati (IR), ripple, SOC (State of Charge), SOH (State of Health), ndi SOP (State of Power). Pokhala ndi ma alarm omwe amapangidwira, kusanthula zochitika, ndi chitetezo chapamwamba cha kutentha, kuwonjezereka, ndi kutulutsa kwambiri, BMS imazindikiritsa zizindikiro zoyamba za kuwonongeka kwa batri zisanakhudze ntchito zovuta.
Amapangidwira kuti azigwirizana ndi ma chemistry ambiri, amathandizira VRLA (Valve-Regulated Lead Acid), Flooded lead-acid, Nickel-Cadmium (Ni-Cd), ndi mabatire a Lithium-ion. Imaphatikizana mosasunthika m'malo opangira ma data, ma telecom base station, masiteshoni, njanji, magalimoto amagetsi, kusungirako mphamvu zongowonjezwdwa, ndi machitidwe amagetsi amakampani, ndikupangitsa kuti ikhale yankho lazonse pazomangamanga zamakono.
Ndi kusanja kwa ma cell, kujambulidwa kwa data pakati, komanso mwayi wofikira pa intaneti, DFUN BMS imathandizira magwiridwe antchito, imachepetsa mtengo wokonza, ndikuwonetsetsa kuti nthawi yayitali - ndikupangitsa kukhala chisankho chodalirika kwa mabizinesi omwe akufuna kasamalidwe ka batri odalirika komanso anzeru.

Ndi DFUN BMS, mabizinesi atha:

Pewani kulephera kwa batire kobisika komanso zoopsa zothawirako ndi kutentha
Sinthani kudalirika kwa UPS ndi telecom network, kuchepetsa nthawi yopuma
Wonjezerani moyo wa batri ndikuchepetsa mtengo wosinthira & kukonza (TCO)
Gwirizanitsani mosasunthika ndi SCADA ndi nsanja zamagetsi zamagetsi
Mavuto a Battery Wamba mu UPS Systems

Kuwonongeka kwa Magwiridwe
Kutaya mphamvu: mphamvu yeniyeni yotsika kuposa yovotera
Kukwera kukana kwamkati: kuchepa kwa kutulutsa bwino chifukwa cha ukalamba/sulfation
Kusalinganika kwa float charge: ma voltages osagwirizana amachepetsa moyo wonse
Kuvuta kuyesa SOC/SOH molondola

Zowonongeka Zamagetsi
Kuchulukira/kutulutsa: kuchititsa kuti madzi atayike, kupindika kwa mbale, kapena kutha kwa kutentha.
Maulendo afupikitsa kapena kutayikira: kumabweretsa kuzimitsa kwa UPS kapena moto
Kulimbana kwakukulu: malo otayirira/ochita dzimbiri amayambitsa kutentha ndi kutaya mphamvu
Kulephera kwa selo imodzi: kokerani pansi chingwe chonse cha batri
Zowopsa Zachilengedwe & Chitetezo
Kutentha kwakukulu kapena kuzizira kosagwirizana: kumapangitsa kuti munthu awonongeke komanso kumayambitsa kusalinganika.
Kuchuluka kwa gasi wa haidrojeni: kumabweretsa chiwopsezo cha kuphulika popanda kuyang'anira bwino komanso mpweya wabwino.
Kutayikira kwa Electrolyte: kumayambitsa dzimbiri, kuopsa kwa chitetezo, ndi zovuta zachilengedwe.
Chiwopsezo cha moto chifukwa cha kutha kwa matenthedwe.
Nkhani Zosamalira & Kasamalidwe
Kuyang'ana pamanja sikuthandiza ndipo nthawi zambiri kumakhala ndi zolakwika
Kuyang'anira kwachilengedwe kwa UPS nthawi zambiri kumangokhala pazingwe zokha
Zovuta kudziwa ma cell omwe akulephera mwachangu
Kusakonzekera zolosera ndi kasamalidwe ka moyo
Battery Bank Reality ndi 'Weakest Cell Effect'
Mavuto amtundu wa ma cell amayambitsa kusalinganika kwamagetsi komanso kulephera kwamphamvu.
Kugwira ntchito kwa batri kumatengera cell yofooka kwambiri.
Maselo ochepa olephera amatha kuchepetsa kwambiri nthawi yosunga zobwezeretsera komanso moyo wautali.
Mphamvu yamagetsi & kusalinganika kwa mphamvu: kumakulitsidwa pambuyo pa kulipiritsa koyandama kwanthawi yayitali
Kusalinganika kwa kutentha: Kugawa kwa kutentha kosafanana kumathandizira kukalamba
Kusalinganiza kwa ndalama / kutulutsa: kugawa kosasinthika kumawononga kusasinthika
Kufupikitsa nthawi yosunga UPS, kuonjezera chiopsezo cha katundu wovuta
Kuchulukitsa kwapang'onopang'ono komanso kukwera mtengo kwa O&M
Kuwonjezeka kwa ziwopsezo zakutulutsa kwambiri komanso kuthawa kwamafuta

DFUN BMS vs Traditional Battery Management
DFUN BMS imapereka chiwongolero chokwanira cha moyo wonse kudutsa VRLA, Ni-Cd, ndi mabatire Osefukira - kuthekera kopitilira kuyang'ana pamanja kapena UPS BMS yachikhalidwe.
| Kanthu | DFUN BMS | Kusamalira Anthu | UPS BMS |
| Kuwunika kwa String SOC | Inde | Mwachisawawa/zosakwanira | Pompopompo |
| Kuyang'anira ma cell a SOC | Inde | Mwachisawawa/zosakwanira | Ayi |
| Kuwunika kwa ma cell a SOH | Inde | Mwachisawawa/zosakwanira | Ayi |
| Ma alarm ndi zolemba | Nthawi yeniyeni, yokwanira, yotsatiridwa | Wogawanika, wosadalirika | Zochepa |
| Malipoti osamalira | Zopangidwa zokha | Zilipo koma zosathandiza | Osathandizidwa |
| Kulozera zolakwika | Inde | Ayi | Ayi |
| Kulinganiza kwa batri | Inde | Ayi | Ayi |
| Zidziwitso zosintha | Inde | Ayi | Ayi |
| Kuwunika kwa ma cell a Ni-Cd 1:1 | Inde | Ayi | Ayi |
| Kusefukira kwa batire ya electrolyte & kuwunika kutayikira | Inde | Ayi | Ayi |
Chifukwa Chiyani Sankhani DFUN BMS?

Kufalikira Kwambiri:
Imathandizira mabatire a VRLA, Ni-Cd, ndi kusefukira kwa zingwe ndi ma cell
Zanzeru & Zolosera:
Ma algorithms oyendetsedwa ndi AI amazindikira zoopsa pasadakhale
Kutsata Chitetezo:
IP65 yotsekereza madzi ndi UL94 yotetezedwa ndi moto pamafakitale owopsa
Kuwunika Kowonjezera:
Imaphatikizira masensa a kutentha kwa chilengedwe ndi chinyezi, zowunikira gasi wa hydrogen, zowunikira zolakwika pansi, ndi masensa a DC kutayikira - kuphimba chilengedwe, mpweya, chitetezo, ndi kuwopsa kwa kutayikira.
High ROI:
Imakulitsa nthawi ya moyo wa batri ndi 20–30%, kuchepetsa mtengo wonse wa umwini
Mapulogalamu a Cross-Industry:
Telecom, malo opangira data, zida zamagetsi, njanji, malo ocheperako, malo opangira mankhwala, mafuta & gasi, zitsulo


Zofunikira za DFUN BMS


Trend modelling and health index evaluation
Zidziwitso zolosera zimakongoletsedwa ndi kusinthana ndikuchepetsa TCO

Kuzindikira ndi kukonza kusalinganika basi
Amatalikitsa moyo wa batri pothetsa 'maselo ofooka kwambiri'






Mapulogalamu a DFUN Battery Monitoring System (BMS)

Telecom Battery Monitoring System
Kuphatikizika kosasunthika pakugwira ntchito mosalekeza kwa telecom
Kumakulitsa moyo wa batri la VRLA, kumachepetsa ngozi yozimitsa
Zapangidwira masiteshoni akutali
Mapulogalamu:
Ma telecom, ma cell akutali, maukonde ang'onoang'ono
Zofunika:

Data Center Battery Monitoring
Imateteza kulephera kwa maselo obisika
Ma alarm olosera amachepetsa kuopsa kwa moto
Kupititsa patsogolo mphamvu zamagetsi, kuchepetsa ndalama zowonjezera
Kuchepetsa mphamvu zapawiri kumawonetsetsa kuti palibe nthawi yopumira
Mapulogalamu:
Malo opangira data, malo azachuma, zomangamanga zamtambo
Zofunika:

PBMS2000Pro - Mphamvu & Railway Industrial BMS
99.5% kupezeka pansi pamagetsi apamwamba, malo ogwedera
40% kuyankha mwachangu komanso kuchepetsa nthawi yokonza mwadzidzidzi
Imathandizira kuwunika kwa ma cell a Ni-Cd 1:1
Imathandizira ma electrolyte a kusefukira kwa batri & kuwunikira kutayikira
Mapulogalamu:
Zida zamagetsi, ma locomotives a njanji, malo owongolera grid
Zofunika:
PBMS2000Pro + Chithunzi cha PBAT71

PBMS9000Pro - Kagawo kakang'ono, mafuta & gasi BMS
Amachepetsa kuphulika kwa madera a petrochemical
IP65 kutsekereza madzi + UL94 kutsekereza moto kuti mukhale otetezeka kwambiri
Mapangidwe osamva dzimbiri kuti akhale odalirika kwa nthawi yayitali
Imathandizira kuwunika kwa ma cell a Ni-Cd 1:1
Mapulogalamu:
Malo ang'onoang'ono, mafakitale amafuta, mafuta & gasi, zitsulo
Zofunika:
Product Center
PBAT Series - Ma cell-Level Monitoring Modules (PBAT51 / PBAT61 / PBAT71 / PBAT81)
| Chitsanzo | Kuyika | Zofunika Kwambiri | Mapulogalamu Ovomerezeka |
| PBAT51 | Mlingo wolowera | Voltage, panopa, kutentha, kuwunika kukana ndi SOC/SOH | Malo opangira data, zipinda zazing'ono zama telecom |
| Chithunzi cha PBAT61 | Standard | Voltage, panopa, kutentha, kuwunika kukana ndi SOC/SOH | Zipinda za UPS, ma telecom apakati |
| Chithunzi cha PBAT71 | Kuwonjezeka kwa Industrial | Magawo athunthu + Ma electrolyte osefukira a batri & kuzindikira kwatayikira | Makina amagetsi, njanji, kugwiritsa ntchito mabatire osefukira |
| PBAT81 | Kutetezedwa Kwambiri | Kapangidwe kopanda moto + kopanda madzi (UL94 / IP65) | Zomera zama Chemical, mafuta & gasi, zitsulo |

FAQ
Q1: Chifukwa chiyani BMS ndiyofunikira pamakina a UPS?
A: Mabatire a UPS nthawi zambiri amavutika ndi kusalinganika, kutaya mphamvu, komanso kuopsa kwa kutentha. BMS imathandizira kuyang'anira ma cell, kuzindikira zolakwika msanga, ndi kukonza zolosera - kuwonetsetsa kudalirika ndikutalikitsa moyo.
Q2: Ndi mitundu yanji ya batri yomwe DFUN BMS imathandizira?
Q3: Kodi DFUN BMS ndi yosiyana bwanji ndi UPS BMS wamba?
Q4: Ndi mafakitale ati omwe amagwiritsa ntchito DFUN BMS?
Mabulogu Ogwirizana
-
Pankhani ya kasamalidwe ka batri, DFUN ndiyodziwika bwino ndi sensa yake yosinthika komanso yanzeru. Zogulitsa zake zakhala zikugwiritsidwa ntchito kwambiri m'ma data, mayendedwe, ndi magawo amagetsi. Nayi kuyang'ana mozama pazowunikira zazikuluzikulu: Sensor ya DFUN: Yofanana ndendende ndi BattMtengo Wolemba
Lumikizanani Nafe
Khalani olumikizana nafe kuti mupeze zosintha zaposachedwa za DFUN Battery Monitoring System, zidziwitso zaukadaulo, ndi mayankho ogwirizana ndi zosowa zanu. Tili nthawi zonse kuti tizimvetsera ndikuthandiza.
Gulu: + 86- 15919182362
Imelo: info@dfuntech.com


