Ku kumeka: | |
---|---|
Nhlayo: | |
- 24/7 wa tiawara ta ku veka tihlo eka inthanete & xitiviso xa tialamu ta le kule .
- Tirhisa eka UPS na data center application .
- Ku pima betri ya lead-acid kumbe ya ti-multi-pole .
- Ku vulavurisana hi ring, ku tsandzeka kwihi na kwihi ka vuhlanganisi a ku nge khumbi vuhlanganisi byin’wana bya switwi .
- Ku languta voltage ya betri, current, impedance, ku lwisana na insulation, ripple current & voltage, SOC, SOH, na swin'wana.
- Tiphurotokholo ta Modbus, SNMP, MQTT na IEC61850 .
- Auto-sensing ya adirese ya ID ya xitwi xa betri .
- Dual-source ku papalata ku pfala gezi .
- Dizayini yo lwisana na ku kavanyeteka, nseketelo wo hlanganisa na UPS ya mpfumawulo wa le henhla .
- Ku landzelela IEEE 1188-2005 .
Muxaka wa betri . | Battery ya lead acid, betri ya multi-pole . |
Xikombelo | Senthara ya Data, UPS . |
CPU . | Xirhendzevutana xa voko A7 528MHz . |
Miehleketo | 512MB Flash, 4G EMMC+ 8G TF Khadi ra memori . |
Tintambhu hinkwato . | Max.6 Tintambhu, total≤420pcs . |
Vuhlanganisi bya le henhla bya vuhlanganisi . | 2 wa swipfalo swa ethernet (10/100m), modbus-TCP, SNMP, IEC61850 . 1 RS485 Ribuwa, Modbus-RTU, Baudrate: 9600bps, 19200bps, 38400bps (hi ku hlawula) |
Phurotokholo ya Vuhlanganisi . | Modbus, SNMP, MQTT na IEC61850 . |
Baudrate . | 1200bps ~ 115200bps . |
Ndhawu ya Ntirho . | Mahiselo yo tirha: -15°C ~ 55°C Ku hlayisa mahiselo: -40°C ~ 70°C Ku kufumela: 5% ~ 95% Ku nga vi na condensing |
- 24/7 wa tiawara ta ku veka tihlo eka inthanete & xitiviso xa tialamu ta le kule .
- Tirhisa eka UPS na data center application .
- Ku pima betri ya lead-acid kumbe ya ti-multi-pole .
- Ku vulavurisana hi ring, ku tsandzeka kwihi na kwihi ka vuhlanganisi a ku nge khumbi vuhlanganisi byin’wana bya switwi .
- Ku languta voltage ya betri, current, impedance, ku lwisana na insulation, ripple current & voltage, SOC, SOH, na swin'wana.
- Tiphurotokholo ta Modbus, SNMP, MQTT na IEC61850 .
- Auto-sensing ya adirese ya ID ya xitwi xa betri .
- Dual-source ku papalata ku pfala gezi .
- Dizayini yo lwisana na ku kavanyeteka, nseketelo wo hlanganisa na UPS ya mpfumawulo wa le henhla .
- Ku landzelela IEEE 1188-2005 .
Muxaka wa betri . | Battery ya lead acid, betri ya multi-pole . |
Xikombelo | Senthara ya Data, UPS . |
CPU . | Xirhendzevutana xa voko A7 528MHz . |
Miehleketo | 512MB Flash, 4G EMMC+ 8G TF Khadi ra memori . |
Tintambhu hinkwato . | Max.6 Tintambhu, total≤420pcs . |
Vuhlanganisi bya le henhla bya vuhlanganisi . | 2 wa swipfalo swa ethernet (10/100m), modbus-TCP, SNMP, IEC61850 . 1 RS485 Ribuwa, Modbus-RTU, Baudrate: 9600bps, 19200bps, 38400bps (hi ku hlawula) |
Phurotokholo ya Vuhlanganisi . | Modbus, SNMP, MQTT na IEC61850 . |
Baudrate . | 1200bps ~ 115200bps . |
Ndhawu ya Ntirho . | Mahiselo yo tirha: -15°C ~ 55°C Ku hlayisa mahiselo: -40°C ~ 70°C Ku kufumela: 5% ~ 95% Ku nga vi na condensing |