
Nea Enti a Monitoring nkutoo Nnɔɔso
Batere a wɔde hwɛ so no betumi ahu nneɛma a ɛnteɛ. Tumi a wɔde sɔ hwɛ betumi ahwɛ sɛ batere no akwahosan te. Nanso batere mpempem pii a wɔbɛhwɛ so wɔ mmeae pii no hwehwɛ sɛ wonya ahotoso atenae a ɛwɔ mfinimfini. DFCS platform no ka bom: Battery Monitoring Capacity Testing AI Analytics Asset Management Alarm Management yɛ no platform biako a wɔaka abom.

Nea Enti a Intanɛt so Nhwehwɛmu + Discharge Capacity Verification Ho Hia

Early warning & second-level alarms a wɔde hu na wɔasiw huammɔdi ano ansa na ayɛ kɛse.
Mfomsoɔ beaeɛ a ɛyɛ pɛpɛɛpɛ kɔsi UPS, battery string, ankorankoro cell, terminal, anaa busbar.
Cloud-based nimdeɛ base ma nteɛso prescriptions,na generates automated nsiesie adwuma ahyɛde.
Closed-loop lifecycle management, a ɛma bere a wɔde yɛ adwuma no so tew na ɛma ahobammɔ yɛ kɛse.
DFCS4200 vs Amanneɛ kwan so Nhwehwɛmu Nhyiamu
| Dwumadie | Amanne kwan so BMS | DFCS4200 na ɛwɔ hɔ |
| Battery a Wɔhwɛ So | ✓ | ✓ |
| UPS Nhwehwɛmu a Wɔyɛ | △ | ✓ |
| AI Nhwehwɛmu | ✗ na ɛyɛ | ✓ |
| Multi-site Management a Wɔde Di Dwuma | △ | ✓ |
| Asetra mu Nneɛma a Wɔde Di Dwuma | ✗ na ɛyɛ | ✓ |
Dɛn Nti na Wopaw DFUN BMS?

Nsɛm a Wɔde Ka Ho Adi Nyinaa:
Ɛboa VRLA, Ni-Cd, ne Flooded battery wɔ string ne cell level nyinaa so
Smart & Nkɔmhyɛ:
AI-powered algorithms di kan hu asiane ahorow
Ahobammɔ ho Mmara a Wodi So:
IP65 nsuo a wɔde siw ano ne UL94 ogya a wɔde siw ano gyinapɛn ma nnwuma a asiane wom
Nhwehwɛmu a Wɔatrɛw mu:
Ɛka nneɛma a atwa yɛn ho ahyia hyew & nsuo a ɛyɛ nwini sensor, hydrogen gas detectors, asase so mfomsoɔ monitors, ne DC leakage sensors bom—ɛkata nneɛma a atwa yɛn ho ahyia, gas, ahobanbɔ, ne leakage asiane so
ROI a ɛkorɔn:
Ɛtrɛw battery nkwa nna mu 20–30%, na ɛtew ɛka a wɔbɔ wɔ ne wurayɛ ho nyinaa so
Nnwuma a Wɔde Di Dwuma wɔ Nnwumakuw Ahorow Ntam:
Telecom, data centers, anyinam ahoɔden adwumayɛbea, keteke akwan, substations, nnuruyɛ adwumayɛbea, oil & gas, metallurgy


DFUN BMS Nneɛma Titiriw


Trend modeling ne akwahosan ho nkyerɛkyerɛmu nhwehwɛmu
Predictive alerts ma nsakraeɛ kyinhyia yɛ yie na ɛtew TCO so

Ɛhu na ɛsiesie nea ɛnkari pɛ no ara kwa
Ɛtrɛw battery nkwa nna mu denam 'weakest cell effect' a osiesie so.






DFUN Battery Monitoring System (BMS) a wɔde di dwuma .

Telecom Battery a Wɔde Hwɛ Nneɛma So
Nkabom a ɛnyɛ den ma telecom adwumayɛ a ɛkɔ so
Ɛtrɛw VRLA battery nkwa nna mu, ɛtew asiane a ɛwɔ hɔ sɛ ɛbɛtwa mu
Wɔayɛ ama akyirikyiri base stations
Nnwuma a Wɔde Di Dwuma:
Telecom stations, akyirikyiri cell sites, nkitahodi nketewa
Nneɛma a Wɔkamfo Kyerɛ:

Data Center Battery a Wɔhwɛ So
Siw nkwammoaa-gyinabea huammɔdi a ahintaw ano
Alarms a wɔde hyɛ nkɔm brɛ ogya ho asiane ase
Ahoɔden a wɔde di dwuma yie, ɛka a wɔbɔ wɔ nsakraeɛ ho no so tew
Dual power redundancy hwɛ hu sɛ zero downtime
Nnwuma a Wɔde Di Dwuma:
Data centers, sikasɛm nhyehyɛe, cloud infrastructure
Nneɛma a Wɔkamfo Kyerɛ:

PBMS2000Pro – Tumi & Keteke Mfiridwuma BMS
99.5% a ɛwɔ hɔ wɔ mmeae a ahoɔden a ɛkorɔn, wosow
Mfomsoɔ ho mmuaeɛ ntɛmntɛm 40% na bere a wɔde siesie ntɛmpɛ no so tew
Ɛboa Ni-Cd 1:1 nkwammoaa a wɔhwɛ so
Ɛboa Battery electrolyte a nsuo ayiri & nsuo a ɛretu no sohwɛ
Nnwuma a Wɔde Di Dwuma:
Tumi a wɔde di dwuma, keteke keteke, mmeae a wɔhwɛ anyinam ahoɔden so
Nneɛma a Wɔkamfo Kyerɛ:
PBMS2000Pro + na ɛwɔ hɔ PBAT71

PBMS9000Pro – Substation,ngo ne gas BMS
Ɛtew asiane a ɛwɔ hɔ sɛ ɛbɛpae wɔ mmeae a wɔde pɛtro yɛ no so
IP65 nsuo a wɔde siw ano + UL94 ogya a wɔde siw ano ma ahobanbɔ kɛseɛ
Nsusuwii a ɛko tia nsɛe a ɛma wotumi de ho to so bere tenten
Ɛboa Ni-Cd 1:1 nkwammoaa a wɔhwɛ so
Nnwuma a Wɔde Di Dwuma:
Substations, nnuruyɛ adwumayɛbea, ngo & gas, dade ho adwumayɛ
Nneɛma a Wɔkamfo Kyerɛ:
PBMS9000Pro + na ɛwɔ hɔ PBAT81 na ɛwɔ hɔ
Nneɛma a Wɔde Yɛ Adwuma
PBAT Series – Nkwammoaa-gyinabea a wɔhwɛ so (PBAT51 / PBAT61 / PBAT71 / PBAT81) .
| Nhwɛsoɔ | Gyinabea a wɔde si hɔ | Nneɛma Titiriw a Ɛwɔ Hɔ | Nnwuma a Wɔkamfo Kyerɛ |
| PBAT51 | Entry-level a wɔde hyɛ mu | Voltage, mprempren, ɔhyew, ahoɔden a wɔde hwɛ so ne SOC/SOH | Data centers, telefon so nkitahodi adan nketewa |
| PBAT61 | Susudua | Voltage, mprempren, ɔhyew, ahoɔden a wɔde hwɛ so ne SOC/SOH | UPS adan, telefon so nkitahodi adwumayɛbea ahorow a ɛwɔ mfinimfini |
| PBAT71 | Industrial Enhanced | Full parameters + Nsuyiri batere electrolyte & leakage detection | Tumi nhyehyɛe, keteke akwan, batere a nsu ayiri afa so a wɔde di dwuma |
| PBAT81 na ɛwɔ hɔ | Ahobammɔ a Ɛkorɔn | Ogya ntumi nkɔ + nsuo ntumi nkɔ mu nhyehyɛɛ (UL94 / IP65) . | Nnuruyɛ adwumayɛbea, ngo & gas, dade ho nimdeɛ |
FAQ
Q1: Dɛn ne batere a wɔde hwɛ nneɛma so (BMS)?
A: Battery Monitoring System (BMS) yɛ nyansa platform a ɛkɔ so di battery parameters atitiriw akyi – te sɛ voltage, emu resistance, temperature, SOC (State of Charge), ne SOH (State of Health) – ma cell biara a ɛwɔ battery string mu.
Q2: Nsonsonoe bɛn na ɛwɔ string-level ne cell-level monitoring ntam?
Q3: Dɛn nti na Battery Monitoring System ho hia ma UPS nhyehyɛe ahorow?
Q4: Battery ahorow bɛn na DFUN BMS boa?
Q5: Nnwuma bɛn na wɔde DFUN BMS di dwuma?
Blog ahorow a ɛfa ho
-
Wɔ mfiridwuma a nyansa wom bere yi mu no, Battery Monitoring Systems (BMS) ne Building Management Systems (BMS) nyinaa ho hia kɛse ma adwumayɛ a etu mpɔn, nanso ɛsono wɔn dwumadi atitiriw no kɛse. Sɛ́ Battery Monitoring System (BMS) adwumayɛfoɔ a wɔyɛ adwumaden no, DFUN ma saa nsonsonoeɛ yi mu da hɔBotae Asɛmti -
Wɔ battery dwumadie mu no, DFUN da nsow wɔ ne sensor a ɛtumi sesa ne nhyehyɛeɛ a ɛyɛ nyansa wɔ tebea nyinaa mu. Wɔde ne nneɛma adi dwuma kɛse wɔ data centers, akwantu, ne ahoɔden adwumayɛbea ahorow. Ɛha na hwɛ a emu dɔ wɔ ade titiriw no nsɛntitiriw: DFUN Sensor: Precisely Matched to BattBotae Asɛmti
Kɔ so Ne Yɛn Nnya Nkitahodi
Tena yɛn nkyɛn na woanya DFUN Battery Monitoring System no ho nsɛm a aba foforo, mfiridwuma ho nhumu, ne ano aduru a wɔayɛ ama w’ahiade. Yɛwɔ ha bere nyinaa sɛ yɛbɛtie na yɛaboa.
Nsɛm a wɔka kyerɛ:+86- 15919182362
E-mail: info@dfuntech.com



