• 2026-09-07 na ɛwɔ hɔ

    UPS Battery Monitoring System a Ɛma Tumi a Wotumi De Ho To So wɔ Akwahosan Dwumadibea
    Ayaresabea batere a wɔde si hɔ no betumi asɛe nkakrankakra na wɔrenhu wɔ nsaano nhwehwɛmu ntam. Saa asɛm yi kyerɛkyerɛ nsɛnnennen atitiriw a ɛfa nsiesie ho ne sɛnea DFUN BMS a ɛkɔ so hwɛ batere biara ne ahama-gyinabea — a ɛkata ahoɔden, ɔhyew, emu ahoɔden a ɛko tia, SOC ne SOH — boa ayaresabea ahorow ma wɔkyere batere a ɛyɛ mmerɛw ntɛm, a wɔde asɛm a ɛfa sɛnea wɔde di dwuma ankasa wɔ Germany ayaresabea bi ayɛ ho mfonini.
  • 2026-08-25 na ɔkyerɛwee

    UPS Battery Internal Resistance: Bere Bɛn na Ɛsɛ sɛ Wosesa?
    Mfinimfini ahoɔden a ɛko tia yɛ VRLA batere akwahosan ho nsɛnkyerɛnne a edi kan a wotumi de ho to so sen biara no mu biako, nanso amansan nɔma biako biara nni hɔ a ɛkyerɛ wo bere a ɛsɛ sɛ wosesa batere — akenkan no kyerɛ biribi a ɛne nkwammoaa no ankasa mfiase nhyia nkutoo. Saa asɛm yi bubu 50%-above-baseline replacement mmara, 20–30% cell-to-cell deviation check a wɔde hu unit a ɛka akyi, ne nea enti a mpofirim ahuru wɔ resistance mu ho hia sen absolute value a ɛkorɔn. Ɛsan nso ka nea enti a resistance nkutoo nnɔɔso — pairing no ne float voltage checks, capacity discharge testing, ne visual inspection — ne sɛnea DFUN’s integrated battery monitoring ne capacity testing platform no ma threshold tracking yɛ adwuma wɔ string mũ no nyinaa so.
  • 2026-08-07 na ɔkyerɛwee

    Battery Monitoring System ma Nsuyiri Lead-Acid Ne Ni-Cd Batere
    lead-acid ne Ni-Cd batere a nsu ayiri afa mu no da so ara ho hia ma DC backup ahoɔden a ɛho hia, nanso nsaano nhwehwɛmu ntumi mma wonhu batere akwahosan bere nyinaa. Hwehwɛ sɛnea DFUN BMS hwɛ ​​ahoɔden, ɔhyew, emu ahoɔden a ɛko tia, SOC, SOH, electrolyte level ne terminal leakage so—ɛboa utilities ne mfiridwuma adwumayɛfo ma wohu mfomso ntɛm, tew nsiesie adwuma so na ɛma backup power ahotoso tu mpɔn.
  • 2026-07-24 na ɛwɔ hɔ

    Substation Battery Monitoring: Mfomso a Wohu Mfiase, Ahobammɔ a Wɔde Di Dwuma, ne Nea Ɛyɛ Mmerewa a Wɔde Bɛka Abom
    Substation battery monitoring ma kɔ so hu cell voltage, emu resistance, ɔhyew, ne string tebea. Saa asɛm yi kyerɛkyerɛ sɛnea utilities betumi ahu battery mfomso ntɛm, ahwɛ Ni-Cd ne VRLA battery, ayɛ biako ne SCADA ne IEC 61850, na ama substation DC ahoɔden ahotoso atu mpɔn.
  • 2026-06-29 na ɛwɔ hɔ

    Telecommunications Battery Monitoring: Akyirikyiri Alarms, OPEX a ɛba fam, Backup Power a Ahobammɔ wom
    Sua sɛnea telecom battery monitoring ma akyirikyiri alarm ahorow tumi yɛ adwuma, ɛtew nsiesie ho ka so, na esiw backup power huammɔdi ano. Hwɛ deɛ wobɛhwɛ so, sɛdeɛ wode bɛdi dwuma, na bisa DFUN nsusuiɛ.
  • 2026-06-09 na ɛwɔ hɔ

    Battery Monitoring Vs Battery Testing: Nsonsonoe & Nsɛm a Wɔde Di Dwuma
    DFUN no smart battery tumi sɔhwɛ ano aduru no ka BMS hwɛ ​​ne tumi a ɛyɛ nokware bom. Sua nkitahodi a ɛda nhwehwɛmu a ɛkɔ so ne tumi sɔhwɛ a ɛyɛ pɛpɛɛpɛ ma tumi nhyehyɛe a ɛho hia ntam.