frankaa

Smart Battery Tumi Sɔhwɛ Ano Aduru

Fie Smart Battery Tumi Sɔhwɛ Ano Aduru

Dɛn Ne Smart Battery Tumi Sɔhwɛ?

Smart Battery Capacity Testing yɛ AI-driven, constant-current discharge technology a ɛhwɛ tumi ankasa (Ah) ne akwahosan tebea (SOH) a battery bank wɔ wɔ bere ankasa mu.

Nea ɛnte sɛ atetesɛm akwan a wɔfa so de nsa gyae adesoa-bank no, DFUN nhyehyɛe no tumi yɛ:

Intanɛt so sɔhwɛ a anyinam ahoɔden ntwa mu

Real-load discharge a nyansa ahobammɔ wom

Automatic tumi akontabuo ne amanneɛbɔ awoɔ ntoatoasoɔ

Akyirikyiri a wɔhwɛ so ne abakɔsɛm mu nneɛma a ɛkɔ so akyi di

Eyi ma ɛyɛ nea eye ma data centers, substations, telecom sites, ne utility control rooms , na ɛhwɛ hu sɛ wɔbɛsiesie batere a ahobammɔ wom, wɔde afiri a wɔde yɛ adwuma, na wɔmfa nni dwuma.

batteryBankTumiSɛhwɛ

Dɛn Nti na Wɔyɛ Batere Tumi Ho Sɔhwɛ Daa?

Im prove System Ahotoso

Batere ahorow hwere ahoɔden bere kɔ so esiane float charging a ɛkyɛ nti. Sɔhwɛ a wɔyɛ no daa no hwɛ hu sɛ wobenya backup a ɛdɔɔso bere a anyinam ahoɔden atwa.

Siw Ahobammɔ Ho Asiane Ano

Tumi sɔhwɛ boa ma wohu nkwammoaa a ɛyɛ mmerɛw anaasɛ adi nkogu ntɛm, na esiw UPS anaa DC anyinam ahoɔden a ɛnyɛ adwuma a wɔnhwɛ kwan ano.

Yɛ Nsiesiei ne Ka a Wɔbɔ no Yiye

Sɔhwɛ a edi mu ma wonya nnyinaso a egyina data so a wɔde besi ananmu, na wɔkwati nsakrae a ɛho nhia wɔ sikakorabea mũ no nyinaa mu.

Du Amanaman Ntam Gyinapɛn ahorow ho dwuma

Ɛne IEC, IEEE, ne GB/T gyinapɛn ahorow a ɛkamfo tumi sɔhwɛ asram 6–12 biara ma nhyehyɛe no mu ahotoso ne akontaabu a wotumi yɛ no hyia.

双ahyɛnsode1-缩小

Anohyeto ahorow a ɛwɔ Amammerɛ mu Tumi Sɔhwɛ mu


Nsaano adesoa-bank sɔhwɛ ma ɔhyew ne ahoɔden a wɔsɛe no dodo


Ɛhwehwɛ sɛ wotwa battery no fi system no mu, na ɛde asiane ba bere a wɔde gyae adwuma no mu


Nsaano data a wɔkyere gu hama so no yɛ nea mfomsoɔ taa ba na ɛnhyia


Sikakorabea baako sɔhwɛ tumi du 50% pɛ wɔ tumi a wɔahyɛ no agyiraeɛ


DFUN sɔhwɛ nhyehyɛe a nyansa wom no nam nhyehyɛe a wɔde di dwuma a ɛyɛ adwuma koraa, AI nhwehwɛmu, ne amanneɛbɔ a egyina mununkum so so yi saa nsɛm yi fi hɔ.

DFUN Mfiridwuma mu Nkɔso


1. Intanɛt so Sɔhwɛ a Zero Ntwitwiridii

K/D nhyehyɛe foforo a ɛwɔ redundancy abien hwɛ hu sɛ nhyehyɛe no kɔ so tra ase bere a wɔreyɛ sɔhwɛ no.


2. Nokware Adesoa Discharge a enni Artificial Ɔhyew

Wɔnam DC/DC nsakrae so san de ahoɔden kɔ DC bɔs no mu, na wɔde adesoa ankasa no di dwuma —a ahobammɔ wom na ɛyɛ adwuma yiye.


3. AI-Gyina Nhwehwɛmu & Tumi Nkɔmhyɛ

AI nhwɛsoɔ a ɛkɔ anim no hwehwɛ voltage, current, ne temperature curves mu de hyɛ SOH ho nkɔm a >95% pɛpɛɛpɛ.


4. Akyirikyiri Dwumadi ne Mununkum Amanneɛbɔ

Bere ankasa mu wɛb nkitahodi a wɔde hwɛ nneɛma so, a PDF/Excel amanneɛbɔ awo ntoatoaso a wɔyɛ no ɔtopae ne akyirikyiri nhwehwɛmu.


5. Multi-Layer Ahobammɔ Ahobammɔ

18 a wɔasisi ahobammɔ mfiri: ɔhyew a ɛboro so, mprempren a ɛboro so, short-circuit, reverse polarity, ne nkitahodi mfomso alarm.

Akyirikyiri Intanɛt so Tumi Sɔhwɛ Nhyehyɛe

Nnwumayɛbea a Wɔde Di Dwuma Ho Nsɛm

DFUN Battery Monitoring System no da nsow wɔ gua so denam ahiade atitiriw a ɛfa battery a wɔde di dwuma yiye, ahobammɔ wom, na ɛyɛ nea wotumi sesa ho a edi ho dwuma no so. Ne akansi mu nkɔso fi adwene a wɔde si pɛpɛɛpɛyɛ, nsakrae, ne ahotoso so —a wɔayɛ no sɛnea ɛbɛyɛ a ɛbɛyɛ adwuma asen ano aduru a wɔtaa de di dwuma wɔ tebea horow a ɛho hia mu.

mfoni

Telecom Tumi Nhyehyɛe (48 V) .

Intanɛt so tumi sɔhwɛ a ɛnyɛ bere a wɔde yɛ adwuma

DC/DC ahoɔden ho nsɛm a wɔde kɔ system bɔs so

Sikakorabea mũ no nyinaa mu sɔhwɛ a wɔde 48 V lithium module ahorow di dwuma

Data a wɔde kokoam amanneɛbɔ a wɔde di dwuma wɔ ɔkwan a ɛyɛ adwuma so

Tumi Dwumadi Nhyehyɛe (110 V / 220 V) .

Grid nkitahodi a ɛyɛ mmerɛw a ɛwɔ adesoa a wɔde gu mu ankasa

Harmonic suppression ne soft current a ɛkɔ soro

Intanɛt so standby ne shallow-cycle nsiesie

IEC 61850 / 104 protocol a ɛne ne ho hyia

Akyirikyiri Intanɛt so Tumi Sɔhwɛ Nhyehyɛe ma Adwumayɛ Tumi a Wɔde Ma (110V220V) .
data beae 1

UPS & Data-Mfinimfini Nhyehyɛe (380 V / 480 V) .

Dual-bus architecture ma asiane biara nni ho a wɔde yi nsuo gu

Sikakorabea ahorow pii sohwɛ a ɛde ne ho

Auto isolation a ɛfa charge circuits ho

Akyirikyiri a wɔde hwɛ nneɛma so a wɔaka abom

1

Dwumadie Nsɛntitiriw

1️⃣ Nokware Adesoa Discharge: PCS-gyina discharge a enni wiring.


2️⃣ Full Online Standby: Bere nyinaa ayɛ krado via daa-to mu diode nhyehyɛe.


3️⃣ Smooth Constant-Current Charging: Siw voltage spikes ne cell nhyɛso ano.


4️⃣ Nhwehwɛmu a ɛkɔ akyiri: Bere ankasa mu ahoɔden, mprempren, ne comms diagnostics.


5️⃣ Harmonic Suppression: Ɛhwɛ hu sɛ grid ahoɔden su no di mmara so.


6️⃣ Battery Maintenance & Open-Circuit Detection: Shallow charge / discharge ma activation ne ntɛm mfomso detection.

2

Mfaso a Ɛwɔ System So

Sɔhwɛ a wɔde afiri yɛ koraa, a obiara nni mu


AI-driven tumi ne nkwa nna nyinaa mu nhwehwɛmu


18-layer ahobanbɔ nhyehyɛe


Amanneɛbɔ a egyina mununkum so ne data a wɔhwehwɛ


Ɛne lead-acid ne lithium nhyehyɛe ahorow hyia


Nkitahodi a ɛnyɛ den ne DFUN PBMS 9000 / 2000

3

Mfiridwuma mu Nsɛntitiriw

Parameter a wɔde kyerɛNsɛm a Wɔakyerɛkyerɛ mu
Voltage Range a Ɛwɔ Hɔ48 V / 110 V / 220 V / 380 V / 480 V
Discharge Mprempren20 A – 240 A (wobetumi ayɛ no sɛnea wɔpɛ) .
Tumi a Ɛwɔ Hɔ≤ 2000 Ah na ɛwɔ hɔ
Nsusuwii a Ɛyɛ Pɛpɛɛpɛ± 1 % FS na ɛwɔ hɔ
Ɔhyew a Wɔde Yɛ Adwumayɛ–10 °C ~ +50 °C na ɛwɔ hɔ
NkutahodieRS-485 / Ethernet / Modbus na ɛyɛ adwuma
Amanneɛbɔ a Wɔde BaAuto PDF / Excel awo ntoatoaso
Ahobammɔ ho AhobammɔOver-current / over-temp / reverse / short-circuit / adwumayɛ a ɛnteɛ a wɔde siw ano

Mfiridwuma Ho Nsɛm a Wɔakyerɛkyerɛ Mu

DFUN Battery Monitoring System no mfiridwuma ho nkyerɛkyerɛmu no kyerɛ adwumayɛ ho nkyerɛkyerɛmu titire ne nhyehyɛɛ ho nsɛm a ɛma ɛyɛ adwuma a wotumi de ho to so na ɛyɛ adwuma pii. Saa nsusuwii ahorow yi ma nhyehyɛe a emu da hɔ a wɔde bɛte sɛnea nhyehyɛe no di nnwuma ahorow ahiade ahorow ho dwuma ase, efi nhwehwɛmu a wɔyɛ no pɛpɛɛpɛ so kosi nhyiam a ɛyɛ den so

Monitoring Parameters & Nneɛma a Ɛwɔ Hɔ

Voltage: 0 - 1500V (nkwaboaa biako), 0 - 10000V (batere ahama); susudua pɛpɛɛpɛ a ɛyɛ ±0.1% FS, a ɛwɔ gyinaesi a ɛyɛ 1mV ma nkwammoaa-gyinabea akyi di pɛpɛɛpɛ Mprempren: -500A kosi +500A (charge/discharge); pɛpɛɛpɛyɛ ±0.2% FS, a shunt resistor a ɛyɛ pɛpɛɛpɛ a ɛkorɔn boa ma ɛkyere micro-current nsakrae mpo.Ɔhyew: -40°C kosi +85°C (ambient ne cell-level); wɔde NTC sensor ahorow 16 a wɔasisi mu (a wotumi trɛw mu kɔ 32) a wɔde hwɛ nneɛma pii so, a ɛhwɛ hu sɛ ɛyɛ pɛpɛɛpɛ ±0.5°C.Impedance: 0.01mΩ to 100mΩ; wɔsusuu denam AC excitation kwan so wɔ 1kHz frequency, a ɛwɔ resolution a ɛyɛ 0.001mΩ de hu nkwammoaa a ɛsɛe ntɛm.


Nkwammoaa a Wɔkari pɛ

Type: Active balancing (ahoɔden a wɔde fa inductive/capacitive coupling so).Balancing current: Ɛkɔ 5A, wotumi sesa wɔ 0.1A nkɔanim mu ma ɛne battery tumi hyia.Balancing voltage nsonsonoe threshold: 20mV - 200mV (a wɔde di dwuma no hyehyɛ denam software so), a auto-balancing activation bere a nsonsonoe boro bo a wɔahyɛ no so. ≥90% sɛnea ɛbɛyɛ a ahoɔden a wɔhwere no so tew bere a nkwammoaa yɛ pɛ.


Nkitahodi & Data a Wɔde Di Dwuma

Protocols: Modbus RTU (RS485, baud rate 9600 - 115200bps), Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (ma ntwamutam sohwɛ), MQTT (ma IoT nkabom), ne IEC 61850 (ma smart grid a ɛne ne ho hyia).Nkitahodi: 2× RS485 hyɛn gyinabea ahorow (a wɔatew wɔn ho, 100Mbps). surge-protected), 1× Ethernet port (RJ45), 1× USB-C (ma mpɔtam hɔ nhyehyeɛ), ne 4G/WiFi module a wopɛ (LTE Cat-M1, 802.11 b/g/n).Data update frequency: Configurable (1s - 60s), a real-time mode (1s interval) ma applications a ɛho hia te sɛ EVs.Storage tumi: 8GB wɔ flash memory, sie kɔsi afe 1 abakɔsɛm mu nsɛm (wɔ simma 5 ntam); boa data a wɔde kɔ amannɔne denam CSV/JSON so.


Nhyehyɛe & Nnwuma a Wɔde Di Dwuma

Nnwuma a Wɔtaa De Di Dwuma:

Data centers, substations, IDC dan, telecom base stations, mfiridwuma adwumayɛbea ahorow, ne keteke kwan so anyinam ahoɔden nhyehyɛe ahorow.

mfoni

UPS / Data-center nhyehyɛe ahorow (380 V / 480 V) .

mfoni

Telecom ahoɔden nhyehyɛe (48 V) .

mfoni

Utility ne substation DC nhyehyɛe (110 V / 220 V) .

beijingtufoɔ

Dɛn Nti na Wopaw DFUN?

Nneɛma bɛboro 3,000 a wɔadi nkonim wɔ wiase nyinaa

Ɛne UPS ne battery brands atitiriw hyia

Ɛboa protocol ahorow a wɔabue: IEC / Modbus / SNMP

Ɛde akyirikyiri nsiesie ne AI nhwehwɛmu dwumadie ma

OEM / system-integration customization a ɛwɔ hɔ

Yɛn Adansedi Krataa

Yɛn botaeɛ a yɛwɔ sɛ yɛbɛma nneɛma ayɛ yie, ahobanbɔ, na yɛadi mmara so no da adi wɔ adansedie a ɛyɛ katee a DFUN Battery Monitoring System no anya no mu. Saa adansedie ahodoɔ yi si so dua sɛ yɛn adeɛ no du wiase nyinaa nnwuma gyinapɛn ho anaa ɛboro so, na ɛma wɔn a wɔde di dwuma no nya ahotosoɔ ne asomdwoeɛ wɔ dwumadie ahodoɔ mu.

证书 na ɛyɛ

Blog ahorow a ɛfa ho

Kɔ so Ne Yɛn Nnya Nkitahodi

Tena yɛn nkyɛn na woanya DFUN Battery Monitoring System no ho nsɛm a aba foforo, mfiridwuma ho nhumu, ne ano aduru a wɔayɛ ama w’ahiade. Yɛwɔ ha bere nyinaa sɛ yɛbɛtie na yɛaboa.

Mob:+86- 15919182362

E-mail: info@dfuntech.com

Nya Battery Nhwehwɛmu a Wontua hwee

Yɛn BMS mfiridwumayɛfoɔ no mu baako bɛbua wɔ nnɔnhwereɛ aduonu nnan ntam.

(Wɔpɛ. Wɔ mfiridwuma ho nsɛm a egye ntɛmpɛ nkutoo ho)

Yɛkyerɛ obu ma wo kokoam nsɛm. Wɔde wo nsɛm no bedi dwuma de abua w’abisade no nkutoo.

Nneɛma a Wɔde Yɛ Adwuma © 2023 DFUN (ZHUHAI) CO., LTD. Hokwan ahorow nyinaa wɔ hɔ. Kokoam Nsɛm Ho Nhyehyɛe | Sitemap a Wɔde Di Dwuma