chij

Smart Battery Capacity Test Solution

Tsev Smart Battery Capacity Test Solution

Smart Battery Capacity Testing yog dab tsi?

Smart Battery Capacity Testing yog ib qho AI-tsav, tas li-tam sim no tso tawm tshuab uas ntsuas lub peev xwm tiag tiag (Ah) thiab lub xeev kev noj qab haus huv (SOH) ntawm lub txhab nyiaj roj teeb hauv lub sijhawm.

Tsis zoo li cov txheej txheem kev tuav pov hwm lub txhab nyiaj ib txwm siv, DFUN system ua tiav:

Kev sim online yam tsis muaj kev cuam tshuam lub zog

Real-load paug nrog kev tiv thaiv ntse

Tsis siv neeg muaj peev xwm suav thiab tshaj tawm kev tsim tawm

Kev saib xyuas tej thaj chaw deb thiab keeb kwm kev taug qab

Qhov no ua rau nws zoo tagnrho rau cov chaw zov me nyuam, chaw ua haujlwm substations, telecom sites, thiab chav tswj hluav taws xob , ua kom muaj kev nyab xeeb, tsis siv neeg, thiab tsis muaj neeg saib xyuas roj teeb..

BatteryBankCapacitTest

Vim li cas thiaj ua Kev Ntsuas Roj Teeb Tsis Muaj Peev Xwm?

Ua pov thawj System Reliability

Cov roj teeb tsis muaj peev xwm dhau lub sij hawm vim yog lub sij hawm ntev float charging. Kev ntsuam xyuas tsis tu ncua ua kom muaj kev thaub qab txaus thaum lub hwj chim tawm.

Tiv Thaiv Kev Nyab Xeeb Kev Nyab Xeeb

Kev kuaj muaj peev xwm pab txheeb xyuas cov hlwb tsis muaj zog lossis ua tsis tau tiav thaum ntxov, tiv thaiv UPS lossis DC lub zog tsis ua haujlwm.

Txhim kho kev tu thiab nqi

Kev ntsuam xyuas raug muab cov ntaub ntawv-tsav lub hauv paus rau kev hloov pauv, zam kev hloov pauv tsis tsim nyog hauv tuam txhab nyiaj.

Ua raws li cov qauv thoob ntiaj teb

Ua raws li IEC, IEEE, thiab GB / T cov qauv qhia kom muaj peev xwm kuaj txhua txhua 6-12 lub hlis rau kev ntseeg siab thiab kev tshuaj xyuas.

双 logo1- 缩小

Cov kev txwv ntawm Kev Ntsuas Cov Peev Xwm Txheej Txheem


Kev ntsuas kev tuav pov hwm lub txhab nyiaj ua kom muaj cua sov thiab lub zog pov tseg


Yuav tsum tau txiav lub roj teeb ntawm lub kaw lus, ua rau muaj kev pheej hmoo poob qis


Kev ceev cov ntaub ntawv kaw yog yuam kev thiab tsis sib xws


Ib qho kev xeem hauv tuam txhab nyiaj tsuas tuaj yeem ncav cuag 50% ntawm cov peev txheej ntsuas


DFUN qhov kev ntsuam xyuas ntse tshem tawm cov teeb meem no los ntawm kev tswj xyuas tag nrho, AI tsom xam, thiab kev tshaj tawm huab.

DFUN Technological Breakthroughs


1. Kev sim online nrog xoom cuam tshuam

Kev tsim kho tshiab K / D qauv nrog dual redundancy ua kom lub kaw lus tseem nyob thaum kuaj.


2. Muaj tseeb Load Discharge yam tsis muaj hluav taws xob hluav taws xob

Lub zog yog pub rov qab rau DC tsheb npav ntawm DC / DC hloov dua siab tshiab, siv qhov tseeb load-kev nyab xeeb thiab ua haujlwm tau zoo.


3. AI-Based Analysis & Peev Prediction

Advanced AI qauv txheeb xyuas qhov voltage, tam sim no, thiab qhov kub thiab txias nkhaus kom kwv yees SOH nrog> 95% raug.


4. Kev khiav hauj lwm chaw taws teeb thiab huab ceeb toom

Real-time web interface rau kev soj ntsuam, nrog cov ntaub ntawv PDF/Excel automated thiab kuaj tej thaj chaw deb.


5. Kev tiv thaiv ntau txheej

18 built-in kev tiv thaiv mechanisms: over-temperature, over-current, short-circuit, reverse polarity, and communication faultalarms.

Tej thaj chaw deb Online Capacity Testing System

Kev lag luam daim ntawv thov Scenario

DFUN Battery Monitoring System sawv tawm hauv kev lag luam los ntawm kev hais txog cov kev xav tau tseem ceeb ntawm kev tswj hwm roj teeb zoo, nyab xeeb, thiab hloov tau. Nws cov kev sib tw sib tw yog los ntawm kev tsom mus rau qhov tseeb, qhov yooj yim, thiab kev ntseeg siab - tsim los ua kom zoo dua cov kev daws teeb meem hauv cov xwm txheej tseem ceeb.

duab

Telecom Fais Fab Systems (48V)

Online peev xwm kuaj nrog xoom downtime

DC/DC lub zog tawm tswv yim rau lub tsheb npav

Kev sim puv txhab nyiaj nrog 48 V lithium modules

Automated encrypted data reporting

Lub zog ua haujlwm (110V / 220V)

Saj zawg zog kab sib txuas nrog qhov tseeb load tawm

Harmonic suppression thiab muag muag tam sim no

Online standby thiab ntiav-lub voj voog tu

IEC 61850 / 104 raws tu qauv kev sib raug zoo

Chaw Taws Teeb Online Kev Ntsuas Qhov Ntsuas rau Kev Siv Hluav Taws Xob (110V220V)
data center 1

UPS & Data-Center Systems (380 V / 480 V)

Dual-bus architecture rau xoom-risk tawm

Independent multi-bank management

Nws pib rho tawm ntawm kev them nqi hluav taws xob

Unified tej thaj chaw deb saib xyuas platform

1

Core Functional Highlights

1️⃣ Muaj tseeb Load Discharge: PCS-raws li tso tawm yam tsis muaj rewiring.


2️⃣ Tag Nrho Online Standby: Ib txwm npaj los ntawm ib txwm-kaw diode tsim.


3️⃣ Smooth Constant-Current Charging: Tiv thaiv qhov voltage spikes thiab cell stress.


4️⃣ Kev Saib Xyuas Kev Paub: Real-time voltage, tam sim no, thiab comms diagnostics.


5️⃣ Harmonic Suppression: Ua kom daim phiaj hluav taws xob ua tau zoo.


6️⃣ Roj Teeb Kho & Qhib-Circuit Detection: Poob nqi / tso tawm rau kev ua kom pom tseeb thiab tshawb pom qhov ua txhaum ntxov.

2

Qhov zoo ntawm qhov system

Tag Nrho automated, unmanned testing


AI-tsav muaj peev xwm thiab kev txheeb xyuas lub neej


18-txheej tiv thaiv architecture


Cloud-based reporting and data traceability


Compatible nrog lead-acid thiab lithium systems


Seamless kev koom ua ke nrog DFUN PBMS 9000 / 2000

3

Technical Highlights

ParameterSpecification
Voltage NtauLub hwj chim: 48V / 110V / 220V / 380V / 480V
Tshem tawm tam sim no20A - 240A (Customizable)
Peev Xwm Ntau≤ 2000 Ah
Kev ntsuas qhov tseeb± 1% FS
Ua haujlwm kub-10 ° C ~ + 50 ° C
Kev sib txuas lusRS-485 / Ethernet / Modbus
Qhia tawmPib PDF / Excel tiam
Kev Tiv Thaiv Kev Nyab XeebTshaj-tam sim no / dhau-temp / thim rov qab / luv-circuit / kev tiv thaiv tsis zoo

Technical Specifications

Cov kev qhia tshwj xeeb ntawm DFUN Battery Monitoring System qhia txog cov kev ntsuas kev ua tau zoo thiab tsim cov ntsiab lus uas ua rau nws txhim khu kev qha thiab ntau yam haujlwm. Cov kev txwv no muab lub hauv paus ntsiab lus meej rau kev nkag siab yuav ua li cas lub kaw lus ua tau raws li kev xav tau ntawm kev lag luam, los ntawm kev soj ntsuam xyuas kom muaj kev sib raug zoo.

Saib xyuas Parameters & Ntau

Voltage: 0 - 1500V (ib lub xov tooj), 0 - 10000V (roj teeb hlua); Kev ntsuas qhov tseeb ntawm ± 0.1% FS, nrog rau kev daws teeb meem ntawm 1mV rau qhov tseeb ntawm tes-theem taug qab.​ Tam sim no: -500A txog +500A (them nqi / tso tawm); Qhov tseeb ± 0.2% FS, txhawb nqa los ntawm high-precision shunt resistor kom ntes txawm tias micro-tam sim no fluctuations. ​​Tsev kub: -40 ° C txog + 85 ° C (ambient thiab cell-level); nruab nrog 16 built-in NTC sensors (exandable mus rau 32) rau ntau lub ntsiab lus saib xyuas, kom ntseeg tau qhov tseeb ntawm ± 0.5 ° C. ​​Impedance: 0.01mΩ txog 100mΩ; ntsuas los ntawm AC excitation method ntawm 1kHz zaus, nrog rau kev daws teeb meem ntawm 0.001mΩ txhawm rau txheeb xyuas cov cell degradation thaum ntxov.


Cell Balancing

Hom: Active ntsuas (lub zog hloov pauv ntawm inductive / capacitive coupling). Qhov ntsuas tam sim no: Txog 5A, kho tau hauv 0.1A increments kom phim lub roj teeb muaj peev xwm. Balancing voltage qhov sib txawv pib: 20mV - 200mV (neeg siv-configurable ntawm software), nrog nws pib-ntsuas qhov ua kom muaj nuj nqis ≥ 0. txo lub zog poob thaum lub sijhawm sib npaug ntawm tes.


Kev sib txuas lus & Kev Tswj Xyuas Cov Ntaub Ntawv

Cov kev cai: Modbus RTU (RS485, baud tus nqi 9600 - 115200bps), Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (rau kev tswj hwm network), MQTT (rau IoT kev sib koom ua ke), thiab IEC 61850 (rau kev sib tw ntse 5 qhov chaw sib txuas RS4 × 8). surge-tiv thaiv), 1 × Ethernet chaw nres nkoj (RJ45), 1 × USB-C (rau kev teeb tsa hauv zos), thiab xaiv tau 4G/WiFi module (LTE Cat-M1, 802.11 b/g/n).​ Cov ntaub ntawv hloov tshiab zaus: Configurable (1s - 60s), nrog rau lub sijhawm cia zoo li lub sijhawm siv (1 GB) flash nco, khaws cia txog li 1 xyoo ntawm cov ntaub ntawv keeb kwm (ntawm 5-feeb ib ntus); txhawb nqa cov ntaub ntawv xa tawm ntawm CSV / JSON.


Siv tau Systems & Industries

Cov ntawv thov raug:

Cov chaw zov me nyuam, cov chaw ua haujlwm substations, IDC chav, chaw nres tsheb hauv xov tooj, cov chaw tsim khoom lag luam, thiab cov tshuab hluav taws xob railway.

duab

UPS / Data-center systems (380V / 480V)

duab

Telecom fais fab system (48V)

duab

Kev siv hluav taws xob thiab hluav taws xob hluav taws xob DC (110V / 220V)

beijingtu

Vim li cas thiaj xaiv DFUN?

Ntau tshaj 3,000 kev teeb tsa ua tiav thoob ntiaj teb

Tau tshaj UPS thiab roj teeb hom

Txhawb cov txheej txheem qhib: IEC / Modbus / SNMP

Muab kev saib xyuas tej thaj chaw deb thiab AI tsom xam cov kev pabcuam

OEM/system-integration customization muaj

Peb Daim Ntawv Pov Thawj

Peb qhov kev cog lus rau kev ua tau zoo, kev nyab xeeb, thiab kev ua raws li tau pom hauv cov ntawv pov thawj nruj heev uas DFUN Battery Monitoring System tau txais. Cov ntawv pov thawj no tau lees paub tias peb cov khoom ua tau raws li lossis tshaj li cov qauv kev lag luam thoob ntiaj teb, ua kom muaj kev ntseeg siab thiab kev thaj yeeb nyab xeeb rau cov neeg siv thoob plaws ntau daim ntawv thov.

证书

Related Blogs

Cia Nrog Peb

Nyob twj ywm nrog peb kom tau txais cov kev hloov tshiab tshiab ntawm DFUN Battery Monitoring System, kev pom zoo, thiab cov kev daws teeb meem rau koj xav tau. Peb ib txwm nyob ntawm no los mloog thiab pab.

Mob: + 15919182362

Email: info@dfuntech.com

Tau txais kev ntsuam xyuas roj teeb dawb

Ib tug ntawm peb BMS engineers yuav teb tsis pub dhau 24 teev.

(Yeem xaiv tau. Tsuas yog rau cov teeb meem ceev ceev)

Peb hwm koj tus kheej. Koj cov ntaub ntawv tsuas yog siv los teb rau koj qhov kev thov.

Copyright © 2023 DFUN (ZHUHAI) CO., LTD. Txhua txoj cai. Txoj Cai Tswjfwm Ntiag Tug | Daim duab qhia chaw