Smart Battery Capacity Testing hmanga thil tih theih a ni
Smart Battery Capacity Testing hi eng nge ni?
Smart Battery Capacity Testing hi AI hmanga siam, constant-current discharge technology a ni a a zirchiang thei a ni . capacity tak tak (Ah) leh state of health (SOH) chu real time-in , battery bank-a
Manual load-bank discharge dan hlui ang lo takin DFUN system hian:
Power tihtawp lohvin online testing neih theih a ni
Real-load discharge leh venhimna fing tak
Automatic capacity chhut leh report siam
Hmun hla tak atanga enfiah leh historical trend tracking
Hei hian tan a tha hle a data center, substation, telecom site, leh utility control room te , battery him, automated, leh unmanned battery enkawlna a tichiang a ni.


Engvangin Nge Battery Capacity Testing hi tih fo thin?
Im prove System Reliability tih hi a ni
Battery te hian hun rei tak chhung float charging an neih avangin an capacity an hloh thin. Test fo hian power outage laiin backup tling tak a awm thei.
Safety Risk awm thei tur ven
Capacity testing hian cell chak lo emaw, fail emaw te chu a hmain a hriat theih nan a pui a, beisei loh taka UPS emaw DC power chhiat a veng thei a ni.
Maintenance leh Costs te pawh a tha thei ang bera siam
Test dik tak hian thlak danglamna tur data-driven basis a pe a, full-bank-a thil tul lo taka tihdanglam a awm loh nan.
International Standards zawm tur a ni
System rintlak leh auditability atan thla 6–12 danah capacity test neih tura rawtna IEC, IEEE, leh GB/T standard zawm.

Traditional Capacity Testing-a tihkhawtlai theihna
Manual load-bank test hian lumna leh chakna bawlhhlawh tam lutuk a siam thin
System atanga battery disconnect a ngai a, chu chuan downtime risk a thlen thin
Manual data recording hi tihsual tamna leh inmil lo a ni
Single-bank test hian rated capacity 50% chauh a thleng thei
DFUN-in intelligent testing system a siam hian heng thilte hi fully automated control, AI analysis, leh cloud-based reporting hmangin a ti bo a ni.
DFUN Technology lama hmasawnna hrang hrang
1. Online Testing neih a ni a, Zero Interruption a awm bawk
Dual redundancy nei K/D structure thar chuan test neih chhungin system chu live-in a awm reng thei a ni.
2. Artificial Heat tel lova Load Discharge dik tak
Energy chu DC/DC conversion hmangin DC bus-ah pek kir leh a ni a, load tak tak hmangin—a him leh efficient.
3. AI hmanga thlirletna & Capacity Prediction
Advanced AI models hian voltage, current, leh temperature curve te chu an zirchiang a, SOH chu >95% dik takin an sawi lawk thei a ni.
4. Hmun hla tak atanga hnathawh leh Cloud Reporting
Monitoring atan real-time web interface, automated PDF/Excel report siamna leh remote diagnosis te a awm bawk.
5. Multi-Layer Hriselna atana venhimna
18 built-in protection mechanisms: temperature sang lutuk, current tam lutuk, short-circuit, reverse polarity, leh communication fault alarm te.

Industry hman dan tur Scenario hrang hrang
DFUN Battery Monitoring System hi market-ah a langsar hle a, battery management tha, him leh inthlak danglam theihna atana mamawh bulpui ber berte a ngaihtuah a ni. A inelna kawngah hian precision, flexibility, leh reliability lam a ngaih pawimawh aangin a lo chhuak a ni—critical scenario-a conventional solutions aiin a hlawhtling zawk tura duan a ni.

Telecom Power System (48 V) hmanga siam chhuah a ni.
Online capacity testing neih a ni a, downtime zero a awm bawk
System bus-a DC/DC energy pek chhuah
Full-bank-a 48 V lithium module hmanga test theih a ni
Encrypted data reporting hmanga tihchhuah a ni
Power hmanga hnathawh dan (110 V / 220 V) .
Load discharge dik tak nena grid connection flexible tak
Harmonic suppression leh soft current sang chhoh dan
Online standby leh shallow-cycle hmanga enkawl
IEC 61850 / 104 protocol nena inmil


UPS leh Data-Center System (380 V / 480 V) hmanga siam a ni.
Zero-risk discharge theihna tur dual-bus architecture
Bank tam tak enkawlna zalen
Charging circuit te chu auto isolation a ni
Remote monitoring platform inzawmkhawm
1
Core Functional Highlights te chu a hnuaia mi ang hian a ni
1️⃣ True Load Discharge: PCS hmanga rewiring tel lova discharge.
2️⃣ Full Online Standby: Normal taka khar diode design hmangin a inpeih reng.
3️⃣ Smooth Constant-Current Charging: Voltage spike leh cell stress a veng thei.
4️⃣ Comprehensive Monitoring: A hun takah voltage, current, leh comms diagnostics te a awm thei.
5️⃣ Harmonic Suppression: Grid power quality zawm a nih theih nan a enkawl.
6️⃣ Battery Maintenance & Open-Circuit Detection: Activation leh fault hriat hmasak nan charge/discharge thuk lo.
2
System thatna te
Fully automated, mihring tel lo testing
AI-driven capacity leh dam chhung zawnga thlirletna
Layer 18-a humhalhna architecture
Cloud-based reporting leh data zawn theihna
Lead-acid leh lithium system nena inmil
DFUN PBMS 9000 / 2000 nena inzawm tlat
3
Technical lam thil pawimawh tak tak
| Parameter a ni | A sawifiahna |
| Voltage Range a ni | 48 V / 110 V / 220 V / 380 V / 480 V a ni |
| Discharge Current a ni | 20 A – 240 A (a duh angin a siam theih) . |
| Capacity Range a ni | ≤ 2000 Ah a ni |
| A tehna dik tak | ± 1 % FS a ni |
| Operating Temperature a ni | –10 °C ~ +50 °C a ni |
| Inbiaktawnna | RS-485 / Ethernet / Modbus hmanga siam a ni |
| Report Output a ni | Auto PDF / Excel hmanga siam chhuah a ni |
| Hriselna atana venhimna | Over-current / over-temp / reverse / short-circuit / hnathawh dik loh venna |
Technical lam thil chi hrang hrang
DFUN Battery Monitoring System-a technical specification-ah hian a hnathawh dan rintlak leh hmanraw hrang hranga hman theihna tur core performance metrics leh design details te tarlan a ni. Heng parameter te hian system hian industry mamawh hrang hrang a phuhruk dan hriatthiamna tur framework chiang tak a pe a, precision monitoring atanga robust compatibility thlengin
Parameters & Ranges te enkawl dan tur
Voltage: 0 - 1500V (cell pakhat), 0 - 10000V (battery string) a ni a; tehna dikna chu ±0.1% FS a ni a, cell-level tracking dik tak atan resolution 1mV a ni.Tunlai: -500A atanga +500A (charge/discharge) accuracy ±0.2% FS, micro-current inthlak danglamna pawh man thei turin high-precision shunt resistor hmanga thlawp Temperature: -40°C atanga +85°C (ambient leh cell-level) multi-point monitoring atan NTC sensor 16 built-in (32 thlenga tihzauh theih) hmanga thuam a ni a, hei hian ±0.5°C a dikna a tichiang a ni Impedance: 0.01mΩ atanga 100mΩ; AC excitation method hmanga 1kHz frequency-a teh a ni a, cell chhiatna hmasa hriat theihna turin resolution 0.001mΩ a ni.
Cell Balancing a ni
Type: Active balancing (inductive/capacitive coupling hmanga energy transfer).Balancing current: 5A thleng, battery capacity nena inmil turin 0.1A increment-a adjust theih.Balancing voltage difference threshold: 20mV - 200mV (software hmanga user-configurable), inthlauhna set value a pelh chuan auto-balancing activation a awm bawk.Balancing efficiency: ≥90% chu cell equalization laiin energy hloh tlem nan a ni.
Inbiakpawhna & Data enkawl dan
Protocol: Modbus RTU (RS485, baud rate 9600 - 115200bps), Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (network management atan), MQTT (IoT integration atan), leh IEC 61850 (smart grid compatibility atan) te Interfaces: 2× RS485 port (isolated, 100Mbps) surge-protected), 1× Ethernet port (RJ45), 1× USB-C (local configuration atan), leh optional 4G/WiFi module (LTE Cat-M1, 802.11 b/g/n) te a awm bawk.Data update frequency: Configurable (1s - 60s), EV ang chi application pawimawh tak tak tan real-time mode (1s interval) a awm bawk.Storage capacity: 8GB in flash memory, storing up to Kum 1 chhunga historical data (minute 5 inkar); CSV/JSON hmanga data export a support bawk.
System & Industries hman tur hrang hrang
A hman dan tlangpui:
Data center, substation, IDC room, telecom base station, industrial plant, leh rel kawng power system te a awm a.

Engvangin Nge DFUN hi kan thlan?
Khawvel pumah installation hlawhtling 3,000 chuang a awm
UPS leh battery brand lian tak tak nena inmil
Open protocol te a support a: IEC / Modbus / SNMP
Remote maintenance leh AI analysis service a pe thin
OEM / system-integration hmanga siam theih a ni

Kan Certificate a ni
Quality, safety, leh compliance lama kan inpekna hi DFUN Battery Monitoring System-in certification khauh tak a hmuhnaah hian a lang chiang hle. Heng certification te hian kan product hian khawvel pum huap industry standard a tlin emaw, a pel emaw tih a nemnghet a, application hrang hranga hmangtute tan rintlak leh rilru thlamuanna a siamsak a ni.

A kaihhnawih blog te .
-
Substation-ah chuan DC system hian hmanraw pawimawh tak tak control circuit, relay venhimna, leh emergency lighting te tan 'lifeline' hna a thawk a ni. Battery bank hi a core energy storage unit angin grid a chhiat laiin 'last line of defense' angin a thawk a ni. Mahse, hmanlai battery enkawlna relieIndustry chanchin thar . -
Energy sector lo thang chak takah hian battery hian energy dahkhawmna hmanrua pawimawh tak angin hmun pawimawh tak a chang a, power supply nghet tak a siam a, energy efficiency a tichak bawk. Mahse, hmanlai battery enkawl dan hian tihkhawtlai tam tak a tawk a, chu chu a thawh that lohna, man to tak, leh himna atana hlauhawm te a ni.WithIndustry chanchin thar .
Kan Inbiakpawhna nei reng rawh
DFUN Battery Monitoring System chungchanga update thar ber ber te, technical insights te, leh i mamawh ang zela tailored solutions te dawng turin kan nen hian inzawm reng ang che. Ngaithla tur leh tanpui turin kan awm reng a ni.
Mob:+86- 15919182362 ah zawhfiah theih a ni
E-mail: info@dfuntech.com thawn theih a ni