In » A chinfel dan tur » Industry chanchin thar » Hlutna Article » Battery Capacity Testing: I hriat tur zawng zawng

Battery Capacity Testing: I hriat tur zawng zawng

Zawhna zawt rawh

facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni


Battery Capacity Testing: I hriat tur zawng zawng


Battery performance-a innghat backup power system tan chuan battery capacity leh a pawimawhzia hriatthiam hi a pawimawh hle.


Battery Capacity Testing hi eng nge ni?


Battery capacity testing hi battery pakhatin electric a vawn theih zat hriat nan hman a ni. He testing hi battery performance leh dam rei theihna tur atan a pawimawh hle. Capacity testing, load testing emaw discharge testing tia hriat bawk hi dynamic test a ni a, battery system-ah hun bituk chhung load dah a ni a, rated capacity chu test result nen khaikhin a ni. Test result hi rated capacity aangin a danglam thei hle a, thil hrang hrangin a nghawng thei a, chu chu battery kum, hman dan, charge/discharge rate, leh temperature te a ni.


Engvangin nge Battery Capacity Testing neih hi?


  • Battery hriselna enfiah: Capacity test fo hian battery hriselna tehna a pui thin. Battery capacity hloh tawh leh thlak ngai te a hriat theih.

  • Battery Performance tihchangtlun: Battery capacity enfiah hian a hmangtute chuan an battery performance a ti tha thei hle. Battery te chu top condition-ah a awm reng theih nan a enkawl a, a tul hunah power rintlak tak a pe thei bawk.

  • Thil awm thei hriat hmasak: Capacity hloh hriat hmasak hian battery a chhiat nghal loh nan a veng thei. User-te chu preemptive measures an la thei a, heng battery hmanga powered device zawng zawngte chu a thawk tha vek tih a tichiang a ni.


Manual Capacity Testing chungchanga thil awmte


Manual Capacity Testing Hriselna atana hlauhawm


  • Hriselna atana hlauhawm

  1. Data Safety: Battery bank chhunga battery chhe tawh a awm chuan battery thenkhat chu over-discharge hlauhawm takah an awm a, chu chuan tihchhiat leh theih loh a thlen thin. Lead-acid battery hian thla thum chhungin a chhe vek theihna chance a sang hle a, manual capacity testing cycle hi kum khat chhung a ni tlangpui a, testing blind spot a siam thin. Tin, offline charge/discharge process-ah power hloh theihna a awm bawk a, hei hian site-a inbiakpawhna hloh emaw, sumdawnna tihbuai emaw a thlen thei bawk.

  2. Environmental Safety: Discharge atan dummy load hman hian thermal hazards a tipung a ni.

  3. Personnel Safety: Charge/discharge process-a battery tihtawp leh inzawm leh hi a buaithlak a, short circuit a awm thei a, chu chuan mimal hliam leh hmanrua a tichhia thei a ni.


Manual Capacity Testing Standardization-a harsatna awmte


  • Standardization lama harsatna awm thei te

    Dispersed site-ah hian hna tam tak a awm a, maintenance personnel tam tak a ngai a, hei hian operational cost sang tak a thlen a ni. Charging leh discharging hmanraw lian tak tak a ngai a, capacity testing zawng zawng hi darkar 24 aia rei a ni tlangpui. Manual recording hi a tha lo va, tihsual leh ngaihdan dik lo a awm fo thin. Battery parameter leh power parameter te hi a inthen a, capacity testing process chhung hian alarm te tan linkage tha tak a awm lo.


DFUN Remote Online Battery Capacity Testing Hman Dan


He solution hi remote online battery capacity tehna atana hmanraw rintlak tak angin a langsar hle. Darkar 8–10 chhung hun rei tak chhung 0.1C online discharge a support a, battery tinte discharge capacity dik takin a chhut a, battery hriselna hriat theihna turin rated capacity nen a khaikhin a ni.


DFUN Remote Online Battery Capacity Testing Hman Dan


  • Battery Life tihzauh

  1. Pre-Charge Function: Bus voltage danglamna a balance a, battery-a high-current charging impact a veng bawk.

  2. Regular Battery Activation: Battery consistency tihchangtlun nan regular activation leh long-term balancing a ti thin.

  3. Big Data Intelligence: Battery lifecycle data a thlirlet a, chu chuan maintenance suggestion leh professional maintenance guidance a pe thin.


  • Safety tihpun

  1. Real Load Discharge: Heat a siam tlem a, energy a hmang tlem bawk.

  2. Remote Non-Contact Testing: Mihringte himna atana hlauhawmna a ti bo.

  3. Comprehensive Strategies: Capacity testing process judgment atan strategy 18 thleng a hmang a, online capacity testing rintlakzia a tichiang a ni. Test neih chhung hian battery leh power parameter te chu a inzawm tlat a, a hun taka warning emaw alert emaw pek theih a ni.


  • Carbon Emission tihtlem

    Capacity test vawi hnih neih nan site khatah electric kWh 100 a humhim thei. International Energy Agency chhinchhiah danin electric kWh khat siam chhuah hian CO2 kilogram 0.78 vel a chhuak a ni. Hei hian kum khatah hmun khata CO2 emission kilogram 78 (2V 1000AH battery hmanga chhut) a tihtlem tihna a ni.

Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah zawhfiah theih a ni

A thuneihna chu 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni