A ziaktu: Site Editor Thuchhuah Hun: 2024-07-24 A chhuahna hmun: Hmun
Battery capacity leh a pawimawhzia hriatthiam hi battery performance-a innghat backup power system atan a pawimawh hle.
Battery capacity testing hi battery pakhatin electric a vawn theih zat hriat theihna atana hman a ni. He test hi battery performance leh dam rei theihna tur atan a pawimawh hle. Capacity testing, load testing emaw discharge testing tia hriat pawh hi dynamic test a ni a, battery system-ah hun bituk chhung atan load a awm a, chu chu test result nen khaikhin a ni. Test result hi rated capacity nen a danglam thei hle a, thil chi hrang hrang, battery age, usage history, charge/discharge rate, leh temperature te hian a nghawng nasa hle.
Battery hriselna enkawl: Regular capacity test hian battery hriselna tehna a pui thin. Battery capacity hloh mek leh thlak ngai te a tarlang a ni.
Battery performance tihsan: Battery capacity chhinchhiah a nih chuan a hmangtute chuan an battery te performance an ti tha thei ang. Battery te chu top condition-ah an awm reng theih nan a enkawl a, a tul hunah power rintlak tak a pe thei bawk.
Thil awm thei tur hriatchhuah hmasak: Capacity hloh hmuhchhuah hmasak chuan battery chhiatna rapthlak tak a veng thei. A hmangtute chu preemptive measures an la thei a, heng battery hmanga powered device zawng zawngte chu a thawk tha thei vek a ni.
Hriselna atana hlauhawmna .
Data Safety: Battery bank chhunga battery chhe tawh a awm chuan battery thenkhat chu over-discharge hlauhawmna a awm a, chu chuan chhiatna a thlen thei lo. Lead-acid battery hian thla thum chhungin a chhe vek theihna a sang hle a, manual capacity testing cycle erawh kum khat a ni tlangpui a, hei hian testing blind spot a siam a ni. Tin, offline charge/discharge process-ah pawh power hloh theihna a awm a, hei hian inbiakpawhna hloh emaw, site-a sumdawnna tihtawp emaw a thlen thei bawk.
Environment Safety: Discharge atana dummy load hman hian thermal hazards a thlen theihna a tipung a ni.
Personnel Safety: Charge/discharge process-a battery inzawmna leh inzawmna siam leh hi a buaithlak hle a, short circuit-a hlauhawmna a awm a, chu chuan mimal hliam leh hmanrua a tichhia thei a ni.
Standardization lama harsatna awmte .
Dispersed sites hian hna tam tak a thawk a, maintenance personnel tam tak a mamawh a, hei vang hian operational cost pawh a sang hle. Charging leh discharging hmanrua lian tak tak a ngai a, capacity testing pumpui hi darkar 24 aia tam a ngai tlangpui. Manual recording hi a hlawk lo hle a, tihsual leh rorelna dik lo a awm awlsam hle. Battery parameter leh power parameter te chu a inthen a, capacity testing process chhung hian alarm tan linkage tha tak a awm lo.
He solution hi remote online battery capacity tehna atana hmanraw rintlak takah a langsar hle. Darkar 8–10 chhung hun rei tak chhung 0.1C online discharge a support a, battery tinte discharge capacity dik tak a chhut a, battery health hriat theihna turin rated capacity nen a khaikhin a ni.
Battery life pawh a ti rei .
Pre-charge function: Bus voltage inthlauhna a balance a, battery-a charging impact sang tak a awm loh nan a veng bawk.
Battery activation pangngai: Battery consistency tichangtlung turin regular activation leh hun rei tak balancing a nei thin.
Big Data Intelligence: Battery lifecycle data a thlirlet a, chu chuan maintenance suggestion leh professional maintenance guidance te chu a pe thin a ni.
Hriselna tihchangtlun .
Real load discharge: Heat a siam tlem zawk a, energy hmang tlem zawk a ni.
Remote non-contact testing: Personnel himna atana hlauhawmna a awm lo.
Comprehensive strategies: Capacity testing process judgments atan strategy 18 thleng a hmang a, online capacity testing rintlakna a tichiang a ni. Test lai hian battery leh power parameter te chu link a ni a, a hun taka warning emaw alert emaw a awm thei.
Carbon emission tihtlem .
Capacity test vawi hnih atan site khatah electric kWh 100 a humhim thei. International Energy Agency chhinchhiah danin, electric kWh khat siam chhuah chuan CO2 kilogram 0.78 vel a chhuah a ni. Hei hian kum tin site khatah CO2 emission kilogram 78 a tihtlem phah a ni (2V 1000AH battery atanga chhut).
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .