Telecom-BTS atanga lo chhuak a ni

Smart Lithium-ion Battery hmangin BMS fing tak a nei bawk


DFUN 48V Telecom & UPS Battery hmanga thil tih theih a ni

In Thil siam chhuah te Smart Lithium-ion Battery hmangin BMS fing tak a nei bawk

Smart Lithium-ion Battery tih hi eng nge ni?

Smart Lithium-ion Battery hi intelligent energy storage system a ni a, lithium cell te chu smart BMS nen a inzawm khawm a, real-time monitoring, hybrid compatibility, leh optimized power performance te a siam thei a ni.


NihphungTraditional Lithium-ion Battery hmanga siam a niDFUN SMART LITHIUM-ION THIL THAWN THAWN THIN
MONITORING THIL AWM DANInbiakpawhna a awm loA hun takah SOC, SOH, Voltage leh Temp
COMPATIBILITY THIL AWM DANLithium chauh a niLead-Acid Battery hmanga hybrid siam a ni
POWER THIL AWM DAN THIL THAWN THINVoltage Output tihfel a niBuilt-In Bidirectional DC/DC hmanga siam a ni
ENKAWLTUA hranpaa, Manual BMSRemote & Centralized hmanga enkawl dan tur
NUN THIL AWM DANCycle Nunna tlemteNun rei tak (≥3000 Cycles) 1.1.

REAL-TIME-A THIL AWM DAN THIL AWM DAN | SOC, SOH, voltage, leh temperature te a track chhunzawm zel.


HYBRID THIL AWM DAN | Lithium-ion leh lead-acid battery te nen a thawk dun a ni.


THIL THAWN THIN DC/DC | Bidirectional converter hian voltage output a ti nghet thei a ni.


INBIAKHAWMNA FULL | CAN, RS485, leh Bluetooth connectivity te a awm bawk.


REMOTE MONITORING THIL AWM DAN | Centralized management leh khawi hmun atang pawhin tracking.

DFUN Smart Lithium-ion Battery hmang hian enterprise hrang hrangte chuan:

A rilru a hah lutuk chuan a rilru a buai em em a. 更换BMS后台图片

A hun takah enfiah a ni

Cell tin voltage, temperature, SOC, SOH te hi a ni

Autonomous humhalhna a ni

Over-charge, over-discharge, short-circuit, thermal tlanchhia te a ni

Hybrid nena inmil theihna

Lead-acid emaw lithium-ion battery dang emaw hmangin a thawk thei

Remote control & data hmanga control theih a ni

Cloud platform emaw local Bluetooth emaw hmangin

Smart Lithium-ion leh Traditional Lithium-ion leh Lead-Acid te an inhmachhawn dawn a ni

NihphungLead-acid a niLithium-ion pangngai tak a niDFUN Smart Lithium-ion hmanga siam a ni
Monitoring neih a ni×Limited a ni☑ A hun takah a awm vek
Nun chhungril lam~500 cycle a ni~1500 cycle a ni≥3000 cycle a ni
Hybrid hman dan××☑ A thlawp a ni
Remote hmanga control theih a ni××☑ Ni e
System Integration a ni××☑ A kim vek
A zau zelLimited a niLimited a niGroup 32 thleng a awm thei

DFUN Smart Lithium-ion hian:


• Fing taka enkawl

• Automatic hmanga venhimna a awm

• Hybrid nena inmil theihna

• Hmun hla tak atanga enkawl


I battery monitoring system chu reactive maintenance atanga predictive & intelligent control ah tidanglam rawh.


DFUN Smart Lithium-ion Battery hnuaia technology bulpui ber berte

Smart BMS tih a ni


Cell-level voltage & temperature enfiah te, SOC/SOH chhut dan te, fault detection te, leh autonomous balancing te a ni.


Ennance sarety thlenga predictive maintenance a thlawp.

Kawng hnih nei DC/DC


Boost, voltage regulation,leh constant-voltage discharge support-in transmission hloh tihtlem leh load handling capacity tihchangtlun.


Voltage nghet zawk, hloh tlem zawk, leh load handling chak zawk.

Smart Hybrid System hmanga siam a ni


Lithium-ion & lead-acid battery combination leh lithium-ion battery thar leh hlui mixed use te a support bawk. Priority discharge logic hian upgrade man leh complexity a ti tlem a ni.


Capital expenditure, upgrade cost, leh deployment complexity a tihtlem.

loT leh Remote Monitoring te a ni


CAN/RS485,remote platform, leh Bluetooth apps te a support bawk.Unattended sites, centralized management, leh real-time diagnostics te a support bawk.


Remote control hmanga enkawl dan tur centralized management

Engvangin Nge DFUN hi kan thlan?

4200 BMS Backup Platform hmanga siam a ni
4200
4200+英文2 a ni
 tih a ni Performance atanga hlawkna a awm


Voltage chhuak reng reng

Power output sang tak (module khatah 4800W thleng) .

Load inthlak danglamnaah chhanna rang

• BMS + DC/DC + Inbiakpawhna inzawmkhawm

Hman senso atanga hlawkna


Enkawlna senso a tlem zawk

Nun rei zawk(≥3000 cycles) .

Battery awmsa hmang leh rawh

• Hybrid battery hmanga hman theih

 tih a ni Hriselna atana hlawkna a awm


Multi-layer hmanga venhimna system

Kangmei chhuah hlauhawmna tihziaawmna

Fault alarm fing tak tak te

• Telecom-grade-a rintlak a ni

Hnathawh lama hlawkna


Hmun hla tak atanga enkawl

Mihring chakna tihtlem

Hrilhfiahna hmanga enkawl

• Khawvel pum huapa deployment finfiah tawh

DFUN Smart Lithium-ion Battery hman dan tur

Telecom BTS / 5G Base Station chakna (48V) hmanga siam a ni.

Remote atanga test la, OPEX kha save rawh

Energy hmanral tihtlem

Battery dam chhung ti sei

Downtime a awm lo

Audit-a inpeih tawh report pek


Dilna hrang hrang:

5G / 4G telecom tower, hmun hla tak tak, tower power backup te a awm bawk

Telecom BTS hmanga inbiakpawhna
Rel hmanga kal theihna tur System te

Rel hmanga kalna tur system (High‐Speed ​​Rail / Metro) 1.1.


Signaling system hrang hrang atan DC 48V backup chhunzawm zel

Thil dik lo sawi lawk thiam (AI-based alerts) .

Built-in DC/DC hmanga voltage chhuak stable

Station hrang hrangah centralized monitoring neih a ni


Dilna hrang hrang:

High-speed rail (HSR), Metro system, Rel signaling & inbiakpawhna room te a awm bawk

Utility / Substation DC System (48V) hmanga siam chhuah a ni.


Battery hman dan kimchang

Hun tak takah diagnostics & predictive maintenance tih a ni

Leilung chhiatna & himna enfiah

Hmun hla tak atanga centralized control


Dilna hrang hrang:

Power utilities, Transmission & distribution substation, Mihring awm lohna station te pawh a awm bawk

Substation DC Systems te chu a hnuaia mi ang hian a ni
Hybrid Energy dahkhawmna system

Hybrid Energy dahkhawmna system (48V ESS) hmanga siam chhuah a ni.


Peak shaving & chakna tihchangtlunna

Renewable integration (ni chakna + dahkhawmna) .

Charge/discharge control fing tak

CAPEX & upgrade complexity tihtlem


Dilna hrang hrang:

Commercial & industrial ESS, Ni zung khawlna system, Microgrid & distributed energy te a awm bawk

Battery Asseseement a thlawna neih theih a ni

Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Product Center ah hian a awm a

Blogs kaihhnawih te

FAQ

Q1:Smart lithium-ion battery leh normal lithium-ion battery te hi eng nge an danglamna?

A: Smart lithium battery-ah hian BMS, communication, leh intelligent control system te a awm a, lithium battery pangngaiah chuan system integration tel lovin energy chauh a khawlkhawm thung.

Q2: String-level leh cell-level monitoring hi eng nge a danglamna?

Q3: Smart lithium-ion battery hian eng chen nge a daih?

Q4: Eng industry nge smart lithium-ion battery hmang thin?

Kan Inbiakpawhna nei reng rawh

DFUN Battery Monitoring System chungchanga update thar ber ber, technical insights, leh i mamawh ang zela tailored solutions te dawng turin kan hnenah hian inzawm reng ang che. Ngaithla tur leh tanpui turin kan awm reng a ni.

Mob:+86- 15919182362 ah zawhfiah theih a ni

E-mail: info@dfuntech.com thawn theih a ni

Chhuifiahna

A thuneihna chu 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni