I-Smart Battery Capacity Testing ubuchwepheshe bokukhipha ibhethri obushayelwa yi-AI, obuhlala bukhona obuhlola umthamo wangempela (Ah) nesimo sempilo (SOH) sebhange lebhethri ngesikhathi sangempela.

Ngokungafani nezindlela zendabuko zokukhipha i-load-bank, uhlelo lwe-DFUN luyazuza:

Ukuhlola ku-inthanethi ngaphandle kokuphazamiseka kwamandla

Ukukhishwa komthwalo wangempela ngokuvikela okuhlakaniphile

Ukubala umthamo okuzenzakalelayo kanye nokwenza umbiko

Ukuqapha okukude nokulandelela izitayela zomlando

Lokhu kuyenza ilungele izikhungo zedatha, iziteshi ezincane, amasayithi okuxhumana ngocingo, namagumbi okulawula izinsiza , ukuqinisekisa ukugcinwa kwebhethri okuphephile, okuzenzakalelayo, nokungenamuntu.

ibhethriBankCapacitTest

Kungani Kufanele Uhlole Umthamo Webhethri Okuvamile?

Thuthukisa Ukwethembeka Kwesistimu

Amabhethri alahlekelwa amandla ngokuhamba kwesikhathi ngenxa yokushaja okuntantayo kwesikhathi eside. Ukuhlola okuvamile kuqinisekisa ikhophi yasenqolobaneni eyanele phakathi nokucisha kukagesi.

Vimbela Izingozi Zokuphepha

Ukuhlolwa kwamandla kusiza ukukhomba amaseli abuthakathaka noma ahlulekile kusenesikhathi, kuvimbele ukuhluleka kwamandla okungalindelekile kwe-UPS noma ye-DC.

Lungiselela Isondlo Nezindleko

Ukuhlola okunembile kunikeza isisekelo esiqhutshwa idatha sokushintshwa, ukugwema izinguquko ezingadingekile zebhange eligcwele.

Hlangana Namazinga Amazwe Ngamazwe

Ithobelana namazinga e-IEC, i-IEEE, kanye ne-GB/T atusa ukuhlolwa kwamandla njalo ezinyangeni eziyi-6–12 ukuze kuthembeke futhi kuhloleke uhlelo.

双logo1-缩小

Imikhawulo Yokuhlolwa Kwekhono Lomdabu


Ukuhlola ibhange lomthwalo okwenziwa ngesandla kukhiqiza ukushisa okudlulele kanye nokumosha amandla


Idinga ukunqanyulwa kwebhethri ohlelweni, okubangela ingozi yokuphelelwa isikhathi


Ukuqoshwa kwedatha mathupha kunephutha futhi akuhambisani


Ukuhlolwa kwebhange elilodwa kungafinyelela kuphela u-50% womthamo olinganiselwe


Isistimu yokuhlola ehlakaniphile ye-DFUN isusa lezi zinkinga ngokulawula okuzenzakalelayo ngokugcwele, ukuhlaziya i-AI, nokubika okusekelwe emafini.

Ukuphumelela Kwezobuchwepheshe kwe-DFUN


1. Ukuhlola Ku-inthanethi Ngokuphazanyiswa OkunguZero

Isakhiwo se-K/D esinobuhlakani obuphindwe kabili siqinisekisa ukuthi isistimu ihlala ibukhoma ngesikhathi sokuhlolwa.


2. Ukukhipha Umthwalo Wangempela Ngaphandle Kokushisa Okwenziwayo

Amandla abuyiselwa ebhasini le-DC ngokuguqulwa kwe-DC/DC, kusetshenziswa umthwalo wangempela—ophephile futhi osebenza kahle.


3. Ukuhlaziya okusekelwe ku-AI kanye nokubikezela kwekhono

Amamodeli e-AI athuthukisiwe ahlaziya amajika kagesi, amanje, kanye nezinga lokushisa ukuze abikezele i-SOH nge>>95% ngokunemba.


4. Ukusebenza kwesilawuli kude nokubikwa kwamafu

Isixhumi esibonakalayo sewebhu sesikhathi sangempela sokuqapha, ngokukhiqizwa kombiko we-PDF/Excel okuzenzakalelayo kanye nokuxilongwa okukude.


5. Ukuvikelwa Kokuphepha Kwezingqimba Eziningi

Izindlela zokuvikela ezakhelwe ngaphakathi eziyi-18: izinga lokushisa elingaphezu kwamandla, over-current, short-circuit, i-reverse polarity, nama-alamu amaphutha okuxhumana.

Isistimu Yokuhlola Ikhono Elikude Le-inthanethi

Izimo Zokusebenza Kwemboni

I-DFUN Battery Monitoring System igqama emakethe ngokubhekana nezidingo ezibalulekile zokuphatha ibhethri okuphumelelayo, okuphephile, nokuguquguqukayo. Imiphetho yayo yokuncintisana isuka ekugxileni ekunembeni, ekuguquguqukeni nasekuthembekeni—okuklanyelwe ukwedlula izixazululo ezivamile ezimeni ezibucayi.

isithombe

I-Telecom Power Systems (48 V)

Ukuhlolwa kwamandla ku-inthanethi nge-zero downtime

DC/DC impendulo yamandla ebhasini lesistimu

Ukuhlolwa kwebhange eligcwele ngamamojula we-lithium angu-48 V

Ukubika idatha ebethelwe ngokuzenzakalelayo

Amasistimu Okusebenza Amandla (110 V / 220 V)

Ukuxhumeka kwegridi okuguquguqukayo nokukhipha umthwalo wangempela

Ukucindezelwa kwe-Harmonic nokukhuphuka kwamanje okuthambile

Ukulinda ku-inthanethi nokugcinwa komjikelezo ongajulile

Ukuhambisana kwephrothokholi ye-IEC 61850/104

Uhlelo Lokuhlola Ikhono Le-inthanethi Elikude Lokuhlinzeka Ngamandla Okusebenza (110V220V)
isikhungo sedatha 1

I-UPS & Data-Center Systems (380 V / 480 V)

Ukwakhiwa kwamabhasi amabili okukhipha ubungozi obuqanda ikhanda

Ukuphathwa okuzimele kwamabhange amaningi

Ukuzihlukanisa ngokuzenzakalela kwamasekhethi wokushaja

Iplathifomu yokuqapha eyirimothi ehlanganisiwe

1

Amaphuzu Avelele Abalulekile

1️⃣ Ukukhishwa Kwemithwalo Yeqiniso: Ukukhishwa okusekelwe ku-PCS ngaphandle kokuhlanganisa kabusha izintambo.


2️⃣ I-Online Standby Egcwele: Ihlala ilungile ngedizayini ye-diode evalekile.


3️⃣ Ukushaja Okuqhubekayo Kwamanje Okushelelayo: Kunqanda ukukhuphuka kwamandla kagesi kanye nengcindezi yamaseli.


4️⃣ Ukuqapha Okuphelele: I-voltage yesikhathi sangempela, yamanje, kanye nokuxilongwa kwe-comms.


5️⃣ I-Harmonic Suppression: Iqinisekisa ukuthobela ikhwalithi yamandla egridi.


6️⃣ Ukugcinwa Kwebhethri Nokutholwa Komjikelezo Ovulekile: Ukushaja okungajulile/ukukhipha ukuze kusebenze nokutholwa kwamaphutha kusenesikhathi.

2

Izinzuzo Zesistimu

Ukuhlola okuzenzakalelayo, okungenamuntu


Amandla aqhutshwa yi-AI kanye nezibalo zokuphila konke


18-ukuvikelwa kwezakhiwo


Ukubika okusekelwe emafu nokulandelelwa kwedatha


Iyahambisana ne-lead-acid kanye ne-lithium systems


Ukuhlanganiswa okungenamthungo ne-DFUN PBMS 9000 / 2000

3

Amaphuzu Avelele Ezobuchwepheshe

IpharamithaUkucaciswa
I-Voltage Range48 V / 110 V / 220 V / 380 V / 480 V
Ukukhipha Okwamanje20 A – 240 A (kungenziwa ngokwezifiso)
Ibanga Lamandla≤ 2000 Ah
Ukunemba Kwesilinganiso± 1 % FS
Izinga Lokushisa Lokusebenza-10 °C ~ +50 °C
UkuxhumanaRS-485 / Ethernet / Modbus
Bika OkukhiphayoI-Auto PDF / Excel isizukulwane
Ukuvikela UkuphephaOkwamanje okwedlulele / okweqile kwesikhashana / ukuhlehla / ukuvimbela isikhashana / ukungasebenzi kahle

Imininingwane Yezobuchwepheshe

Imininingwane yobuchwepheshe ye-DFUN Battery Monitoring System iveza amamethrikhi okusebenza abalulekile kanye nemininingwane yedizayini evumela ukusebenza kwayo okuthembekile nokuguquguqukayo. Le mingcele ihlinzeka ngohlaka olucacile lokuqonda ukuthi isistimu ihlangabezana kanjani nezidingo zemboni ezihlukahlukene, kusukela ekuqaphelweni okunembayo kuya ekusebenzisaneni okuqinile.

Ukuqapha Amapharamitha & Ububanzi

I-Voltage: 0 - 1500V (iseli elilodwa), 0 - 10000V (intambo yebhethri); ukunemba kokulinganisa kwe-±0.1% FS, ngokulungiswa okungu-1mV kokulandelela okunembile kweleveli yeseli.​ Okwamanje: -500A kuya ku-+500A (ukushaja/ukukhulula); ukunemba okungu-±0.2% FS, okusekelwa i-shunt resistor enembe kakhulu ukuze ibambe ngisho nokuguquguquka okuncane kwamanje. ifakwe izinzwa ze-NTC ezakhelwe ngaphakathi eziyi-16 (ezinwebekayo ziye ku-32) zokuqapha amaphuzu amaningi, ukuqinisekisa ukunemba kwe-±0.5°C.​ Ukuphazamiseka: 0.01mΩ kuya ku-100mΩ; kulinganiswa ngendlela ye-AC excitation ku-1kHz, ngokulungiswa okungu-0.001mΩ ukuze kutholwe ukuwohloka kweseli kwangaphambi kwesikhathi.


Ukulinganisa Kweseli

Uhlobo: Ukulinganisa okusebenzayo (ukudluliswa kwamandla nge-inductive/capacitive coupling).​ Ibhalansila okwamanje: Ifika ku-5A, ilungiseka ngokunyuka okungu-0.1A ukuze ifane nomthamo webhethri. ​ Ukulinganisa umehluko we-voltage threshold: 20mV - 200mV (okulungiseka umsebenzisi ngesofthiwe), ngokusebenza kokulinganisa okuzenzakalelayo kweqa ibhalansi engu-9% uma kuqhathaniswa nokulinganisa. ukunciphisa ukulahleka kwamandla ngesikhathi sokulinganisa kwamaseli.


Ukuxhumana Nokuphathwa Kwedatha

Amaphrothokholi: I-Modbus RTU (RS485, izinga le-baud 9600 - 115200bps), i-Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (yokuphatha inethiwekhi), i-MQTT (yokuhlanganiswa kwe-IoT), kanye ne-IEC 61850 (yokusebenzisa igridi ehlakaniphile 5× amachweba ahlanganisiwe angu-4: 2 × i-surge-protected), 1× Ethernet port (RJ45), 1× USB-C (yokucushwa kwasendaweni), kanye nemojula ye-4G/WiFi engakhethwa (LTE Cat-M1, 802.11 b/g/n).​ Imvamisa yokubuyekezwa kwedatha: Iyalungiseka (1s - 60s), enemodi yesikhathi sangempela (1s Storage space 8 GB) yomthamo wesitoreji esibalulekile 8 GB. kuze kufike onyakeni ongu-1 wedatha yomlando (ngezikhawu zemizuzu emi-5); isekela ukuthunyelwa kwedatha nge-CSV/JSON.


Amasistimu Nezimboni Ezisebenzayo

Izinhlelo zokusebenza ezijwayelekile:

Izikhungo zedatha, iziteshi ezincane, amagumbi e-IDC, iziteshi ze-telecom, izitshalo zezimboni, namasistimu kagesi wezitimela.

isithombe

Amasistimu we-UPS / Data-center (380 V / 480 V)

isithombe

Amasistimu kagesi weTelecom (48 V)

isithombe

Izinsiza kanye neziteshi ze-DC (110 V / 220 V)

eBeijing

Kungani Khetha i-DFUN?

Ngaphezulu kokufakwa okuyimpumelelo okungu-3,000 emhlabeni jikelele

Ihambisana ne-UPS enkulu nemikhiqizo yebhethri

Isekela amaphrothokholi avuliwe: IEC / Modbus / SNMP

Ihlinzeka ngokulungiswa okukude kanye nezinsizakalo zokuhlaziya i-AI

Ukwenza ngokwezifiso kwe-OEM / ukuhlanganiswa kwesistimu kuyatholakala

Isitifiketi Sethu

Ukuzibophezela kwethu kwikhwalithi, ukuphepha, nokuthobelana kubonakala ezitifiketini eziqinile ezizuzwe yi-DFUN Battery Monitoring System. Lezi zitifiketi ziqinisekisa ukuthi umkhiqizo wethu uhlangabezana noma weqa izindinganiso zemboni yomhlaba wonke, okuqinisekisa ukwethembeka nokuthula kwengqondo kubasebenzisi kuzo zonke izinhlelo zokusebenza ezihlukahlukene.

证书

Amabhulogi Ahlobene

  • Inani Lohlelo Lwesixazululo Sokuhlola Umthamo Webhethri Eku-inthanethi Esikude
    Ukuze kuhlolwe umthamo wamaphakethe ebhethri kumasistimu wamandla ayisipele, okwamanje kunezindlela ezimbili eziyinhloko: ukuhlola umthamo okuvamile nokuhlola umthamo we-inthanethi okukude. Ukuhlolwa kwamandla omdabu kuncike ekuxhumeni imithwalo ye-dummy mathupha ukuze ihlole ngayinye futhi iqinisekise amabhethri ekuhlakazweni kuka
    I-athikili Yenani
  • Ukuhlola Amandla Ebhethri: Konke Odinga Ukukwazi
    Izinkinga Zokuhlola Amandla NgokuzenzelaUkuphepha Kwedatha: Uma kunamabhethri awonakele ngaphakathi kwebhange lebhethri, amanye amabhethri asengozini yokuchitheka ngokweqile, abangele umonakalo ongalungiseki. Amabhethri e-lead-acid anethuba eliphezulu lokonakaliswa ngokuphelele phakathi nezinyanga ezintathu, kuyilapho i-manual capaci
    I-athikili Yenani
  • Isiqiniseko Sokuphepha Sesistimu Yokuhlola Amandla Ebhange Lebhethri
    Amandla okukhipha angempela amabhethri abesebenza ngaphansi kwezimo zokushaja okuntantayo isikhathi eside awavamile ukungaqondakali. Ukuthembela kuphela ezindleleni ezivamile zokuhlola umthamo kunikeza ukunemba okulinganiselwe. Ngenkathi izinguquko ku-voltage yebhethri kanye nokumelana kwangaphakathi kungabonisa kancane
    I-athikili Yenani
  • Isimiso Sokuhlola Ikhono Ngobuchwepheshe Bebhethri Inverter Grid-Connected
    Isendlalelo Sokuhlolwa Kwekhono Ku-inthanethiNgokuthuthukiswa okukhaliphile kwezinhlelo zamandla kanye nenani elandayo leziteshi ezingaphansi, umthwalo wokulungiswa kwezinhlelo ze-DC usufuna kakhulu, futhi isidingo sokuqapha nokugcinwa okuhlakaniphile kwamabhethri siya ngokuya siphuthuma. Bat
    I-athikili Yenani

Xhumana Nathi

Hlala uxhumene nathi ukuze uthole izibuyekezo zakamuva Zohlelo Lokuqapha Ibhethri le-DFUN, imininingwane yobuchwepheshe, nezixazululo eziklanyelwe izidingo zakho. Sihlala sikhona ukuze silalele futhi sisize.

Isixuku: +86- 15919182362

I-imeyili: info@dfuntech.com

Thola Ukuhlolwa Kwebhethri Kwamahhala

Omunye wonjiniyela bethu be-BMS uzophendula engakapheli amahora angama-24.

(Ongakukhetha. Ngezinkinga zobuchwepheshe eziphuthumayo kuphela)

Siyayihlonipha imfihlo yakho. Ulwazi lwakho luzosetshenziswa kuphela ukuphendula isicelo sakho.

Copyright © 2023 DFUN (ZHUHAI) CO., LTD. Wonke Amalungelo Agodliwe. Inqubomgomo yobumfihlo | Imephu yesayithi