
Ngwọta Nleba Ike Batrị Smart
Kedu ihe bụ nnwale ikike batrị Smart?
Nnwale ikike batrị nke smart bụ teknụzụ na-agbapụta AI, na-enyocha ikike (Ah) na ọnọdụ ahụike (SOH) nke ụlọ akụ batrị ozugbo.
N'adịghị ka usoro mbupu ụlọ akụ akwụkwọ ntuziaka ọdịnala, usoro DFUN na-enweta:
Nnwale n'ịntanetị na-enweghị nkwụsị ike
Mwepu n'ezie na nchekwa ọgụgụ isi
Ngụkọ ikike akpaaka na ọgbọ mkpesa
Nleba anya na nsochi usoro akụkọ ihe mere eme
Nke a na-eme ka ọ dị mma maka ebe data, ọdụ ụgbọ ala, saịtị telecom, na ụlọ njikwa ọrụ , na-ahụ maka nchekwa, akpaaka, na mmezi batrị na-enweghị isi..


Gịnị kpatara na-eme nnwale ike batrị oge niile?
Gosipụta ntụkwasị obi Sistemu
Batrị na-efunahụ ike ka oge na-aga n'ihi chaja ise n'elu mmiri na-adịte aka. Nnwale oge niile na-eme ka nkwado ndabere zuru oke n'oge nkwụsị ọkụ.
Gbochie ihe egwu nchekwa
Nnwale ike na-enyere aka ịchọpụta mkpụrụ ndụ adịghị ike ma ọ bụ dara ada n'oge, na-egbochi ọdịda ike UPS ma ọ bụ DC na-atụghị anya ya.
Welie nlekọta na ọnụ ahịa
Nnwale ziri ezi na-enye ndabere data na-akwado maka nnọchi, na-ezere mgbanwe ụlọ akụ zuru oke na-enweghị isi.
Zute ụkpụrụ mba ụwa
Dabara na ụkpụrụ IEC, IEEE, na GB/T na-akwado nnwale ikike kwa ọnwa 6-12 ọ bụla maka ntụkwasị obi sistemụ na nyocha.

Mmachi nke Nnwale ike Omenala
Nnwale ibu-ụlọ akụ n'aka na-ebute oke ọkụ na mkpofu ume
chọrọ iwepụ batrị na sistemụ, na-ebute ihe egwu oge
Ndekọ data akwụkwọ ntuziaka na-adaba adaba na enweghị nkwekọ
Nnwale otu ụlọ akụ nwere ike iru naanị 50% nke ikike akwadoro
Sistemụ nnwale ọgụgụ isi nke DFUN na-ewepụ okwu ndị a site na njikwa akpaaka zuru oke, nyocha AI na akụkọ sitere na igwe ojii.
Mmepe teknụzụ DFUN
1. Nnwale ntanetị na nkwụsị efu
Nhazi K/D ohuru nwere ihe eji arụ ọrụ abuo na-eme ka sistemụ ahụ dị ndụ n'oge ule.
2. Ezi Ibu Ntufu na-enweghị Okpomọkụ Artificial
A na-enyeghachi ike n'ime ụgbọ ala DC site na ntụgharị DC/DC, na-eji ezigbo ibu - dị mma na nke ọma.
3. Nyocha dabere na AI & amụma ike
Ụdị AI dị elu na-enyocha voltaji, nke dị ugbu a, na akụkụ okpomọkụ iji buru amụma SOH na> 95% ziri ezi.
4. Ọrụ ime obodo na akụkọ igwe ojii
Ngwa weebụ dị adị maka nleba anya, yana ọgbọ mkpesa PDF/Excel na-akpaghị aka na nyocha dịpụrụ adịpụ.
5. Multi-Layer Safety Protection
Usoro nchekwa 18 arụnyere n'ime ya: oke okpomoku, nke na-adị ugbu a, mkpirisi okirikiri, ntụgharị polarity, na mkpu mmejọ nkwukọrịta.

Ihe ngosi Ngwa ụlọ ọrụ
Sistemụ nlekota batrị DFUN pụtara n'ahịa site n'ịgbasa isi mkpa nke njikwa batrị dị mma, nchekwa na nke nwere ike imeghari. Akụkụ asọmpi ya na-esite na nlebara anya na izi ezi, mgbanwe na ntụkwasị obi-emebere ka ọ pụta ìhè n'ụzọ dị egwu n'ọnọdụ dị oke egwu.

Sistemụ Ike Telecom (48V)
Nnwale ikike n'ịntanetị yana oge nkwụsị efu efu
DC/DC ume nzaghachi ụgbọ ala sistemụ
Nnwale ụlọ akụ zuru oke yana modul lithium 48V
Ozi data ezoro ezo akpaghị aka
Sistemu arụ ọrụ ike (110V/220V)
Njikọ grid na-agbanwe agbanwe yana ezigbo mwepu ibu
Mbelata nke nkwekọ na ịrị elu dị nro ugbu a
Ndokwa n'ịntanetị na mmezi okirikiri na-emighị emi
IEC 61850/104 ndakọrịta protocol


UPS & Sistemụ Ebe Ebe Data (380V/480V)
Ihe owuwu ụgbọ ala abụọ maka mwepu ihe egwu efu
Njikwa ọtụtụ ụlọ akụ nwere onwe
Kewapụrụ sekit ịchaji na akpaaka
Ejikọtara ọnụ nleba anya nleba anya
1
Isi ihe na-arụ ọrụ
1️⃣ Ezi Ibupu Ibu Ibu: Mwepu sitere na PCS na-enweghị rewiring.
2️⃣ Njikere n'ịntanetị zuru oke: dị njikere mgbe niile site na imewe diode mechiri emechi.
3️⃣ Nchaji na-adị ugbu a: Na-egbochi mbelata voltaji na nrụgide cell.
4️⃣ Nleba anya zuru oke: voltaji oge, nke ugbu a na nchọpụta comms.
5️⃣ Harmonic Suppression: Na-eme ka nrube isi ike grid.
6️⃣ Nlekọta batrị & nchọpụta oghere-emeghe: ụgwọ na-adịghị emetụ n'ahụ / mwepu maka ịgbalite na ịchọpụta mmejọ mbụ.
2
Uru Sistemu
Nnwale akpaaka zuru oke, enweghị mmadụ
Ikike AI na-akwalite yana nyocha oge ndụ
18-ọkwa nchekwa ihe owuwu
Mgbasa ozi sitere na igwe ojii yana nchọta data
Dakọtara na sistemu-acid na lithium
Mmekọrịta enweghị nkebi na DFUN PBMS 9000/2000
3
Ihe ngosi nka
| Oke | Nkọwapụta |
| Oke voltaji | 48 V / 110 V / 220 V / 380 V / 480 V |
| Mwepu ugbu a | 20 A - 240 A (nwere ike ịhazi ya) |
| Oke ikike | ≤2000 ah |
| Ịdị nha nha | ± 1% FS |
| Okpomọkụ na-arụ ọrụ | -10 °C ~ +50 Celsius |
| Nzikọrịta ozi | RS-485 / Ethernet / Modbus |
| Kwupụta Mpụta | Auto PDF / Excel ọgbọ |
| Nchedo nchekwa | Over-current / over- temp / reverse / short-circuit / mis-operation prevention |
Nkọwa nka nka
Nkọwa teknụzụ nke DFUN Battery Monitoring System na-akọwapụta metrik arụmọrụ bụ isi na nkọwa imewe nke na-eme ka ọ rụọ ọrụ nke a pụrụ ịdabere na ya na nke dị iche iche. Paragraf ndị a na-enye usoro doro anya maka ịghọta ka sistemụ ahụ na-egbo mkpa ụlọ ọrụ dị iche iche, site na nleba anya nkenke ruo na ndakọrịta siri ike.
Nleba anya oke & oke
Voltaji: 0 - 1500V (otu cell), 0 - 10000V (eriri batrị); nha nha nke ± 0.1% FS, yana mkpebi nke 1mV maka nsochi ọkwa ọkwa cell. izi ezi ± 0.2% FS, nke onye na-emegide shunt na-akwado nke ọma iji weghara ọbụna mgbanwe micro-ugbu a. Okpomọkụ: -40°C ruo +85°C (ambient and cell-level); Ejiri ihe mmetụta NTC 16 wuru n'ime ya (gbasaa na 32) maka nleba anya ọtụtụ ihe, na-ahụ maka izi ezi nke ± 0.5°C. Impedance: 0.01mΩ ruo 100mΩ; tụrụ site na usoro mkpali AC na ugboro 1kHz, yana mkpebi nke 0.001mΩ iji chọpụta mmebi cell mbụ.
Nhazi cell
Ụdị: Ntụle na-arụ ọrụ (nnyefe ike site na njikọ inductive / capacitive) . Ịhazi ugbu a: Ruo 5A, mgbanwe na 0.1A na-abawanye iji kwekọọ ikike batrị wedata ọnwụ ike n'oge nhata cell.
Nkwukọrịta & Njikwa Data
Usoro: Modbus RTU (RS485, baud ọnụego 9600 - 115200bps), Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (maka netwọk njikwa), MQTT (maka IoT mwekota), na IEC 61850 (maka smart gridRS4: 5 × Interface. (dịpụrụ adịpụ, echebe-echebe), 1 × Ethernet ọdụ ụgbọ mmiri (RJ45), 1 × USB-C (maka nhazi mpaghara), na nhọrọ 4G/WiFi modul (LTE Cat-M1, 802.11 b/g/n). ruo afọ 1 nke data akụkọ ihe mere eme (na nkeji nkeji 5); na-akwado mbupụ data site na CSV/JSON.
Sistemụ & ụlọ ọrụ dị
Ngwa ahụkarị:
Ebe data, ọdụ ụgbọ ala, ọnụ ụlọ IDC, ọdụ ọdụ telecom, ụlọ ọrụ mmepụta ihe, na sistemu ike ụgbọ oloko.

Kedu ihe kpatara ịhọrọ DFUN?
Ihe karịrị nrụnye 3,000 na-aga nke ọma n'ụwa niile
dakọtara na isi UPS na ụdị batrị
Na-akwado protocol mepere emepe: IEC / Modbus / SNMP
Na-enye ndozi anya na ọrụ nyocha AI
OEM / nhazi-mmekọrịta sistemụ dị

Asambodo anyi
Nkwenye anyị maka ịdị mma, nchekwa, na nnabata na-egosipụta na asambodo siri ike nke sistemụ nlekota batrị DFUN nwetara. Asambodo ndị a na-akwado na ngwaahịa anyị na-ezute ma ọ bụ karịa ụkpụrụ ụlọ ọrụ zuru ụwa ọnụ, na-ahụ na ntụkwasị obi na udo nke uche maka ndị ọrụ n'ofe ngwa dị iche iche.

Blọọgụ ndị emetụtara
Na-akpọtụrụ Anyị
Jikọọ na anyị ka ị nweta mmelite kachasị ọhụrụ na Sistemụ Nlebaanya Batrị DFUN, nghọta teknụzụ, yana ngwọta ahaziri maka mkpa gị. Anyị na-anọ ebe a mgbe niile ige ntị na inye aka.
Otu igwe mmadụ:+ 15919182362
Email: info@dfuntech.com


