ọkọlọtọ

Ngwọta Nleba Ike Batrị Smart

Ụlọ Ngwọta Nleba Ike Batrị Smart

Kedu ihe bụ nnwale ikike batrị Smart?

Nnwale ikike batrị nke smart bụ teknụzụ na-agbapụta AI, na-enyocha ikike (Ah) na ọnọdụ ahụike (SOH) nke ụlọ akụ batrị ozugbo.

N'adịghị ka usoro mbupu ụlọ akụ akwụkwọ ntuziaka ọdịnala, usoro DFUN na-enweta:

Nnwale n'ịntanetị na-enweghị nkwụsị ike

Mwepu n'ezie na nchekwa ọgụgụ isi

Ngụkọ ikike akpaaka na ọgbọ mkpesa

Nleba anya na nsochi usoro akụkọ ihe mere eme

Nke a na-eme ka ọ dị mma maka ebe data, ọdụ ụgbọ ala, saịtị telecom, na ụlọ njikwa ọrụ , na-ahụ maka nchekwa, akpaaka, na mmezi batrị na-enweghị isi..

batrịBankCapacitTest

Gịnị kpatara na-eme nnwale ike batrị oge niile?

Gosipụta ntụkwasị obi Sistemu

Batrị na-efunahụ ike ka oge na-aga n'ihi chaja ise n'elu mmiri na-adịte aka. Nnwale oge niile na-eme ka nkwado ndabere zuru oke n'oge nkwụsị ọkụ.

Gbochie ihe egwu nchekwa

Nnwale ike na-enyere aka ịchọpụta mkpụrụ ndụ adịghị ike ma ọ bụ dara ada n'oge, na-egbochi ọdịda ike UPS ma ọ bụ DC na-atụghị anya ya.

Welie nlekọta na ọnụ ahịa

Nnwale ziri ezi na-enye ndabere data na-akwado maka nnọchi, na-ezere mgbanwe ụlọ akụ zuru oke na-enweghị isi.

Zute ụkpụrụ mba ụwa

Dabara na ụkpụrụ IEC, IEEE, na GB/T na-akwado nnwale ikike kwa ọnwa 6-12 ọ bụla maka ntụkwasị obi sistemụ na nyocha.

双logo1-缩小

Mmachi nke Nnwale ike Omenala


Nnwale ibu-ụlọ akụ n'aka na-ebute oke ọkụ na mkpofu ume


chọrọ iwepụ batrị na sistemụ, na-ebute ihe egwu oge


Ndekọ data akwụkwọ ntuziaka na-adaba adaba na enweghị nkwekọ


Nnwale otu ụlọ akụ nwere ike iru naanị 50% nke ikike akwadoro


Sistemụ nnwale ọgụgụ isi nke DFUN na-ewepụ okwu ndị a site na njikwa akpaaka zuru oke, nyocha AI na akụkọ sitere na igwe ojii.

Mmepe teknụzụ DFUN


1. Nnwale ntanetị na nkwụsị efu

Nhazi K/D ohuru nwere ihe eji arụ ọrụ abuo na-eme ka sistemụ ahụ dị ndụ n'oge ule.


2. Ezi Ibu Ntufu na-enweghị Okpomọkụ Artificial

A na-enyeghachi ike n'ime ụgbọ ala DC site na ntụgharị DC/DC, na-eji ezigbo ibu - dị mma na nke ọma.


3. Nyocha dabere na AI & amụma ike

Ụdị AI dị elu na-enyocha voltaji, nke dị ugbu a, na akụkụ okpomọkụ iji buru amụma SOH na> 95% ziri ezi.


4. Ọrụ ime obodo na akụkọ igwe ojii

Ngwa weebụ dị adị maka nleba anya, yana ọgbọ mkpesa PDF/Excel na-akpaghị aka na nyocha dịpụrụ adịpụ.


5. Multi-Layer Safety Protection

Usoro nchekwa 18 arụnyere n'ime ya: oke okpomoku, nke na-adị ugbu a, mkpirisi okirikiri, ntụgharị polarity, na mkpu mmejọ nkwukọrịta.

Sistemụ Nleba Ike Ọnlaịnụ

Ihe ngosi Ngwa ụlọ ọrụ

Sistemụ nlekota batrị DFUN pụtara n'ahịa site n'ịgbasa isi mkpa nke njikwa batrị dị mma, nchekwa na nke nwere ike imeghari. Akụkụ asọmpi ya na-esite na nlebara anya na izi ezi, mgbanwe na ntụkwasị obi-emebere ka ọ pụta ìhè n'ụzọ dị egwu n'ọnọdụ dị oke egwu.

foto

Sistemụ Ike Telecom (48V)

Nnwale ikike n'ịntanetị yana oge nkwụsị efu efu

DC/DC ume nzaghachi ụgbọ ala sistemụ

Nnwale ụlọ akụ zuru oke yana modul lithium 48V

Ozi data ezoro ezo akpaghị aka

Sistemu arụ ọrụ ike (110V/220V)

Njikọ grid na-agbanwe agbanwe yana ezigbo mwepu ibu

Mbelata nke nkwekọ na ịrị elu dị nro ugbu a

Ndokwa n'ịntanetị na mmezi okirikiri na-emighị emi

IEC 61850/104 ndakọrịta protocol

Sistemụ Nleba Ike Ọnlaịnụ maka ịnye ike arụ ọrụ (110V220V)
data center 1

UPS & Sistemụ Ebe Ebe Data (380V/480V)

Ihe owuwu ụgbọ ala abụọ maka mwepu ihe egwu efu

Njikwa ọtụtụ ụlọ akụ nwere onwe

Kewapụrụ sekit ịchaji na akpaaka

Ejikọtara ọnụ nleba anya nleba anya

1

Isi ihe na-arụ ọrụ

1️⃣ Ezi Ibupu Ibu Ibu: Mwepu sitere na PCS na-enweghị rewiring.


2️⃣ Njikere n'ịntanetị zuru oke: dị njikere mgbe niile site na imewe diode mechiri emechi.


3️⃣ Nchaji na-adị ugbu a: Na-egbochi mbelata voltaji na nrụgide cell.


4️⃣ Nleba anya zuru oke: voltaji oge, nke ugbu a na nchọpụta comms.


5️⃣ Harmonic Suppression: Na-eme ka nrube isi ike grid.


6️⃣ Nlekọta batrị & nchọpụta oghere-emeghe: ụgwọ na-adịghị emetụ n'ahụ / mwepu maka ịgbalite na ịchọpụta mmejọ mbụ.

2

Uru Sistemu

Nnwale akpaaka zuru oke, enweghị mmadụ


Ikike AI na-akwalite yana nyocha oge ndụ


18-ọkwa nchekwa ihe owuwu


Mgbasa ozi sitere na igwe ojii yana nchọta data


Dakọtara na sistemu-acid na lithium


Mmekọrịta enweghị nkebi na DFUN PBMS 9000/2000

3

Ihe ngosi nka

OkeNkọwapụta
Oke voltaji48 V / 110 V / 220 V / 380 V / 480 V
Mwepu ugbu a20 A - 240 A (nwere ike ịhazi ya)
Oke ikike≤2000 ah
Ịdị nha nha± 1% FS
Okpomọkụ na-arụ ọrụ-10 °C ~ +50 Celsius
Nzikọrịta oziRS-485 / Ethernet / Modbus
Kwupụta MpụtaAuto PDF / Excel ọgbọ
Nchedo nchekwaOver-current / over- temp / reverse / short-circuit / mis-operation prevention

Nkọwa nka nka

Nkọwa teknụzụ nke DFUN Battery Monitoring System na-akọwapụta metrik arụmọrụ bụ isi na nkọwa imewe nke na-eme ka ọ rụọ ọrụ nke a pụrụ ịdabere na ya na nke dị iche iche. Paragraf ndị a na-enye usoro doro anya maka ịghọta ka sistemụ ahụ na-egbo mkpa ụlọ ọrụ dị iche iche, site na nleba anya nkenke ruo na ndakọrịta siri ike.

Nleba anya oke & oke

Voltaji: 0 - 1500V (otu cell), 0 - 10000V (eriri batrị); nha nha nke ± 0.1% FS, yana mkpebi nke 1mV maka nsochi ọkwa ọkwa cell. izi ezi ± 0.2% FS, nke onye na-emegide shunt na-akwado nke ọma iji weghara ọbụna mgbanwe micro-ugbu a. Okpomọkụ: -40°C ruo +85°C (ambient and cell-level); Ejiri ihe mmetụta NTC 16 wuru n'ime ya (gbasaa na 32) maka nleba anya ọtụtụ ihe, na-ahụ maka izi ezi nke ± 0.5°C. Impedance: 0.01mΩ ruo 100mΩ; tụrụ site na usoro mkpali AC na ugboro 1kHz, yana mkpebi nke 0.001mΩ iji chọpụta mmebi cell mbụ.


Nhazi cell

Ụdị: Ntụle na-arụ ọrụ (nnyefe ike site na njikọ inductive / capacitive) . Ịhazi ugbu a: Ruo 5A, mgbanwe na 0.1A na-abawanye iji kwekọọ ikike batrị wedata ọnwụ ike n'oge nhata cell.


Nkwukọrịta & Njikwa Data

Usoro: Modbus RTU (RS485, baud ọnụego 9600 - 115200bps), Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (maka netwọk njikwa), MQTT (maka IoT mwekota), na IEC 61850 (maka smart gridRS4: 5 × Interface. (dịpụrụ adịpụ, echebe-echebe), 1 × Ethernet ọdụ ụgbọ mmiri (RJ45), 1 × USB-C (maka nhazi mpaghara), na nhọrọ 4G/WiFi modul (LTE Cat-M1, 802.11 b/g/n). ruo afọ 1 nke data akụkọ ihe mere eme (na nkeji nkeji 5); na-akwado mbupụ data site na CSV/JSON.


Sistemụ & ụlọ ọrụ dị

Ngwa ahụkarị:

Ebe data, ọdụ ụgbọ ala, ọnụ ụlọ IDC, ọdụ ọdụ telecom, ụlọ ọrụ mmepụta ihe, na sistemu ike ụgbọ oloko.

foto

UPS/Sistemụ etiti data (380V/480V)

foto

Sistemụ ike ekwentị (48V)

foto

Utility na substation DC sistemụ (110V / 220V)

beijingtu

Kedu ihe kpatara ịhọrọ DFUN?

Ihe karịrị nrụnye 3,000 na-aga nke ọma n'ụwa niile

dakọtara na isi UPS na ụdị batrị

Na-akwado protocol mepere emepe: IEC / Modbus / SNMP

Na-enye ndozi anya na ọrụ nyocha AI

OEM / nhazi-mmekọrịta sistemụ dị

Asambodo anyi

Nkwenye anyị maka ịdị mma, nchekwa, na nnabata na-egosipụta na asambodo siri ike nke sistemụ nlekota batrị DFUN nwetara. Asambodo ndị a na-akwado na ngwaahịa anyị na-ezute ma ọ bụ karịa ụkpụrụ ụlọ ọrụ zuru ụwa ọnụ, na-ahụ na ntụkwasị obi na udo nke uche maka ndị ọrụ n'ofe ngwa dị iche iche.

证书

Blọọgụ ndị emetụtara

  • Njikọ nke Nnwale ikike dịpụrụ adịpụ yana batrị smart lithium ---- ihe ọhụrụ na arụ ọrụ ike ndabere na ọnọdụ mmezi.
    N'ime ọdụ ụgbọ ala, sistemụ DC na-arụ ọrụ dị ka 'Lifeline' maka akụrụngwa dị oke mkpa dị ka sekit njikwa, nchebe mgbagharị, na ọkụ mberede. Ụlọ akụ batrị, dị ka ngalaba nchekwa ike ya, na-arụ ọrụ dị ka 'ahịrị nchebe ikpeazụ' n'oge ọdịda grid. Agbanyeghị, mmezi batrị ọdịnala dabere
    Akụkọ ụlọ ọrụ
  • Na-eduga Oge Ọhụrụ nke mmezi batrị: Sistemụ Nleba Ike Ọnlaịnụ
    Na ngalaba ike na-agbanwe ngwa ngwa, batrị na-arụ ọrụ dị oke mkpa dị ka ngwaọrụ nchekwa ike dị mkpa, na-eme ka ọkụ eletrik kwụsie ike na ịkwalite nrụpụta ike. Agbanyeghị, ụzọ edozi batrị ọdịnala na-eche ọtụtụ oke ihu, dị ka arụghị ọrụ nke ọma, ọnụ ahịa dị elu na ihe egwu nchekwa.Na
    Akụkọ ụlọ ọrụ
  • Nkwenye nchekwa maka Sistemụ Nleba ikike nke ụlọ akụ batrị
    A naghị amakarị ikike ịwepu batrị ndị na-arụ ọrụ n'okpuru ọnọdụ chajị n'elu ruo ogologo oge. Ịdabere naanị na usoro nnwale ikike na-enye oke oke. Ọ bụ ezie na mgbanwe na voltaji batrị na nguzogide ime nwere ike igosi akụkụ ụfọdụ
    Akụkọ ụlọ ọrụ
  • Mkpa nke Nnwale Ike Ọnlaịnụ dị
    01 Ebumnuche nke Nnwale ike batrị Iji nyochaa ma nyochaa ikike na arụmọrụ nke batrị ahụ. Iji hụ na batrị ahụ na-emezu ihe achọrọ arụ ọrụ a na-atụ anya ya. Site na nyocha ikike, ghọta nke ọma State of Health (SOH) nke eriri batrị wee chọpụta adịghị mma kwa
    Akụkọ ụlọ ọrụ

Na-akpọtụrụ Anyị

Jikọọ na anyị ka ị nweta mmelite kachasị ọhụrụ na Sistemụ Nlebaanya Batrị DFUN, nghọta teknụzụ, yana ngwọta ahaziri maka mkpa gị. Anyị na-anọ ebe a mgbe niile ige ntị na inye aka.

Otu igwe mmadụ:+ 15919182362

Email: info@dfuntech.com

Nweta nlele batrị efu

Otu n'ime ndị injinia BMS anyị ga-aza n'ime awa 24.

(Nhọrọ. Naanị maka okwu teknụzụ ngwa ngwa)

Anyị na-akwanyere nzuzo gị ùgwù. A ga-eji ozi gị naanị iji zaghachi arịrịọ gị.

Nwebiisinka © 2023 DFUN (ZHUHAI) CO., LTD. Ikike niile echekwabara. amụma nzuzo | map saịtị