pankarti

Batiri seko sɛgɛsɛgɛli fɛɛrɛ hakilitigi

So Batiri seko sɛgɛsɛgɛli fɛɛrɛ hakilitigi

Batiri hakilitigi seko sɛgɛsɛgɛli ye mun ye?

Smart Battery Capacity Testing ye AI-driven, constant-current discharge technology ye min bɛ jateminɛ waati yɛrɛ la. seko yɛrɛ (Ah) n’a kɛnɛya cogoya (SOH) batiri banki

DFUN ka baarakɛcogo tɛ i n’a fɔ bololabaarakɛlaw ka doni-banki bɔli fɛɛrɛw, a bɛ se ka :

Ɛntɛrinɛti sɛgɛsɛgɛli ni kuran tɛ tigɛ

Doni lakika bɔli ni lakanani hakilitigi ye

Seko ni dɔnko jatebɔ otomatiki ani rapɔɔri bɔli

Yɔrɔjan kɔlɔsili ani tariku taabolo nɔfɛtaama

O b’a to a ka ɲi kunnafonidilanw, telewisɔn fitininw, telefɔni yɔrɔw, ani utilité control rooms , ka batiri ladonni sabati, otomatiki, ani mɔgɔ tɛ min na.

batiriBankiKapacitTest

Mun na an bɛ batiri seko sɛgɛsɛgɛli kɛ tuma bɛɛ?

Im prove Sistɛmu Daŋaniya

Batiriw bɛ bɔnɛ u seko la waati tɛmɛnen kɔfɛ ka da a kan u bɛ charge (sara) waati jan kɔnɔ. Kɔrɔbɔli tuma bɛɛ bɛ kɛ sababu ye ka kɔpi caman sɔrɔ kuran tiɲɛni waati.

Aw bɛ Lakanali Faratiw bali

Seko ni dɔnko sɛgɛsɛgɛli bɛ dɛmɛ ka selilu barikamaw walima selilu dɛsɛlenw dɔn joona, ka UPS walima DC kuran tiɲɛni bali min ma labɛn.

Ladonni ni musakaw kɛcogo ɲuman

Kɔrɔbɔli tigitigi bɛ basigi di kunnafoniw ma minnu bɛ tali kɛ fɛnw falenni na, ka an yɛrɛ tanga banki dafalen caman caman cili ma minnu tɛ mako ɲɛ.

Dugukolo kan sariyaw labato

Ka kɛɲɛ ni IEC, IEEE ani GB/T sariyaw ye minnu bɛ seko ni dɔnko sɛgɛsɛgɛli laadi kalo 6–12 o kalo 6–12 walasa ka sistɛmu dannaya ni jateminɛ kɛ.

双logo1-Bamanankan_kalangafe4-zup.repl.html

Laadalata seko sɛgɛsɛgɛli dantigɛliw


Bololabaarakɛlaw ka doni-banki sɛgɛsɛgɛli bɛ funteni ni fanga tiɲɛni kojugu lase


A b’a ɲini ka batiri tigɛ ka bɔ sistɛmu la, o bɛ kɛ sababu ye ka baarakɛbaliya farati lase


Bololabaarakɛlaw ka kunnafoniw sɛbɛnni ye filiw ye, wa u tɛ bɛn ɲɔgɔn ma


Banki kelen sɛgɛsɛgɛliw bɛ se ka se 50% dɔrɔn ma seko hakɛ jateminɛlen na


DFUN ka sɛgɛsɛgɛli kɛcogo hakilitigi bɛ nin ko ninnu ban ni otomatiki kɔlɔsili dafalen ye, AI sɛgɛsɛgɛli, ani sankaba-ka-marako.

DFUN ka seko ni dɔnko yiriwali


1. Ɛntɛrinɛti kan sɛgɛsɛgɛli ni Zero Interruption ye

K/D jɔcogo kura ni redundancy fila bɛ a to sistɛmu ka to ɲɛnamaya la kɔrɔbɔli waati.


2. Doni bɔli lakika ni funteni dilannen tɛ

Fanga bɛ segin ka don DC bisi kɔnɔ DC/DC jiginni fɛ, ka baara kɛ ni doni yɛrɛ ye—a lakananen don ani a bɛ baara kɛ ka ɲɛ.


3. AI-Based Analysis & Seko ni dɔnko fɔli

AI misali kɔrɔlenw bɛ sɛgɛsɛgɛli kɛ tension, current ani temperature curves kan walasa ka SOH fɔ ni >95% tiɲɛni ye.


4. Yɔrɔjan baarakɛcogo ani sankaba laseli

Waati yɛrɛ la ɛntɛrinɛti yɔrɔ kɔlɔsili kama, ni PDF/Excel rapɔɔri bɔli ye otomatiki la ani yɔrɔjan sɛgɛsɛgɛli.


5. Lakanali lakanani caman-caman

18 lakanani fɛɛrɛ minnu bɛ don a kɔnɔ : funteni tɛmɛnen, kuran tɛmɛnen, kurukuruni, kɔsegin polarite, ani kumaɲɔgɔnya fili alarma.

Yɔrɔjan ɛntɛrinɛti seko sɛgɛsɛgɛli sira

Industriw ka baarakɛcogo ɲɛfɔli

DFUN batiri kɔlɔsili sira bɛ bɔ sugu la, a kɛtɔ ka batiriw maracogo ɲuman, lakananen, ani min bɛ se ka ladilan, o mago jɔnjɔnw ɲɛnabɔ. A ka ɲɔgɔndan dancɛw bɛ bɔ sinsin kɛli la tigitigi, fɛn caman sɛgɛsɛgɛli, ani dannaya kan — min dabɔra walasa ka tɛmɛ furakɛlicogo kɔrɔw kan ko gɛlɛnw na.

ja

Telefɔni kuran siraw (48 V) .

Ɛntɛrinɛti seko sɛgɛsɛgɛli ni jɔli waati zeru

DC/DC fanga seginni ka ɲɛsin sistɛmu bisi ma

Banki dafalen sɛgɛsɛgɛli ni 48 V litiyamu moduluw ye

Kunnafoni sirilenw lakalicogo otomatiki

Seko ni dɔnko baarakɛcogo (110 V / 220 V) .

Rezo jεɲɔgɔnya min bε se ka bεn ni doni bɔli lakika ye

Harmonic suppression ani soft current wulicogo

Ɛntɛrinɛti kan labɛnni ni cycle shallow-cycle ladonni

IEC 61850 / 104 protocole bɛnkan

Yɔrɔjan ɛntɛrinɛti seko sɛgɛsɛgɛli sira min bɛ baara kɛ ni kuran sɔrɔyɔrɔw ye (110V220V) .
kunnafonidilan 1.

UPS & Data-Centre Sistɛmuw (380 V / 480 V) .

Busi fila jɔcogo ka ɲɛsin zeru-risk bɔli ma

Banki caman ɲɛnabɔli yɛrɛmahɔrɔnyalen

Charge circuits (sarali sɛrɛkiliw) ka u yɛrɛ bɔ ɲɔgɔn na

Yɔrɔjan kɔlɔsili yɔrɔ kelen

1

Baarakɛcogo jɔnjɔnw (Core Functional Highlights).

1️⃣ True Load Discharge: PCS-based discharge ni wiring tɛ a la.


2️⃣ Full Online Standby: A labɛnnen don tuma bɛɛ diode normalement-closed design fɛ.


3️⃣ Smooth Constant-Current Charging: A bɛ voltage spikes ni cellule stress bali.


4️⃣ Kɔlɔsili bɛɛ lajɛlen: Waati yɛrɛ la voltage, current, ani comms diagnostics.


5️⃣ Harmonic Suppression: A bɛ a to rezow fanga jogo ka labatoli.


6️⃣ Batiri ladonni & Open-Circuit Detection: Charge/discharge min man dun walasa ka baara kɛ ani ka filiw dɔn joona.

2

Sisεmεti Nafaw

Kɔrɔbɔli min bɛ kɛ otomatiki la pewu, mɔgɔ tɛ min na


AI-driven capacité ani ɲɛnamaya kɔnɔ sɛgɛsɛgɛli


18-layɛrɛ lakanani jɔcogo


Sankaba-ka-marako ni kunnafoniw ɲinini


A bɛ bɛn ni plɔmu-asidi ni litiyamu sitɛmuw ye


Jɛɲɔgɔnya min tɛ fɛn tiɲɛ ni DFUN PBMS 9000 / 2000 ye

3

Fɛnɲɛnɛmako ɲɛnamaw

ParamɛtiriKɛrɛnkɛrɛnnenya la
Voltage Range (Sɔrɔdasi-yɔrɔ).48 V / 110 V / 220 V / 380 V / 480 V
Discharge Current (Kɔrɔlen).20 A – 240 A (a bɛ se ka kɛ ka kɛɲɛ ni mɔgɔw sago ye) .
Seko ni dɔnko Range≤ 2000 Ah ye
Sumanikɛcogo Tiɲɛni± 1 % FS ye
Baarakɛcogo funteni–10 °C ~ +50 °C
KunnafoninRS-485 / Ɛtɛrinɛti / Modbus
Rapport bɔliAuto PDF / Excel sɛnɛfɛnw bɔli
Lakanali LakanaliKuran tɛmɛnen / funteni tɛmɛnen / kɔsegin / kurukuru / baarakɛcogo jugu kunbɛnni

Fɛɛrɛko ɲɛfɔli

DFUN batiri kɔlɔsili sira ka fɛɛrɛbɔcogo ɲɛfɔlenw bɛ baarakɛcogo jateminɛ jɔnjɔnw n’a dilancogo kunnafoniw jira minnu b’a to a ka baara kɛcogo bɛ se ka da a kan ani min bɛ se ka kɛ fɛn caman na. O paramɛtiriw bɛ sigida jɛlen di walasa ka faamuyali sɔrɔ cogo min na sigida in bɛ izini mago suguya caman ɲɛ, k’a ta kɔlɔsili tigitigi la ka se bɛnkan barikama ma

Kɔlɔsili Paramɛtiriw & Dakunw

Voltage : 0 - 1500V (seli kelen), 0 - 10000V (batiri juru); sumanikɛcogo ɲuman ye ±0,1% FS ye, ni a janya ye 1mV ye walasa ka se ka selilɛri hakɛ nɔfɛtaama tigitigi kɛ Sisan: -500A ka se +500A ma (sara/bɔ); tiɲɛni ±0,2% FS, min bɛ dɛmɛ ni shunt resistor ye min ka bon kosɛbɛ walasa ka hali micro-current jiginniw minɛ Funteni : -40°C ka se +85°C ma (ambient ani cell-level) a bɛ ni NTC sensɛri 16 ye minnu bɛ don a kɔnɔ (a bɛ se ka bonya ka se 32 ma) walasa ka yɔrɔ caman kɔlɔsili kɛ, ka a to a ka tiɲɛni bɛ se ±0,5°C ma.Impedansi : 0,01mΩ fo 100mΩ suman AC excitation fɛɛrɛ fɛ 1kHz frequency la, ni resolution ye 0,001mΩ ye walasa ka selilu tiɲɛni joona dɔn.


Selilɛriw ka balansi (Balancing cellules).

Sugu: Balance active (energy transfer via coupling inductive/capacitive).Balancing current: Fo 5A, adjustable in 0,1A increments to match battery capacity.Balancing voltage difference threshold: 20mV - 200mV (a bɛ se ka labɛn baarakɛla fɛ porogaramu fɛ), ni auto-balancing activation ye ni danfara minnu tɛmɛna nafa latigɛlen kan. ≥90% walasa ka fanga bɔnɛ dɔgɔya selilɛriw ka ɲɔgɔn sɔrɔli waati.


Kumaɲɔgɔnya & Donanw ɲɛnabɔli

Protocoles : Modbus RTU (RS485, baud rate 9600 - 115200bps), Modbus TCP (Ethernet, 10/100Mbps), SNMP v3 (ka ɲɛsin rezow ɲɛnabɔli ma), MQTT (ka ɲɛsin IoT jɛli ma), ani IEC 61850 (ka ɲɛsin smart grid bɛnkan ma). surge-protected), 1× Ethernet port (RJ45), 1× USB-C (for local configuration), ani optional 4G/WiFi module (LTE Cat-M1, 802.11 b/g/n) Donanw ladamuni frequency: Configurable (1s - 60s), ni real-time mode (1s interval) ye baarakɛminɛn nafamaw kama i n’a fɔ EVs.Storage capacity: 8GB internal memory, storing up to tariku kunnafoniw san 1 (miniti 5 cɛ); bɛ kunnafonidilanw bɔli dɛmɛ CSV/JSON fɛ.


Sistɛmuw & Industries minnu bɛ baara kɛ

Baarakɛcogo minnu bɛ Kɛ cogoya la:

Donanw, jagokɛyɔrɔw, IDC sobaw, telefɔni basigiyɔrɔw, iziniw, ani nɛgɛso kuran siraw.

ja

UPS / Donanw-santiriw (380 V / 480 V) .

ja

Telefɔni kuran siraw (48 V) .

ja

Nafama ni substation DC sitɛmuw (110 V / 220 V) .

beijingtu ye

Mun na an bɛ DFUN sugandi?

Installation 3000 ni kɔ ye ɲɛtaa sɔrɔ diɲɛ kɔnɔ

A bɛ bɛn UPS ni batiri suguyabaw ma

A bɛ da wulilenw dɛmɛ: IEC / Modbus / SNMP

A bɛ yɔrɔjan ladonni ni AI sɛgɛsɛgɛli baara kɛ

OEM / sistɛm-integration customization bɛ sɔrɔ

An ka Sɛbɛnni

An ka cɛsiri ka ɲɛsin jogoɲumanya, lakana ani sariya labatoli ma, o bɛ ye seereyaw gɛlɛnw na minnu sɔrɔla DFUN batiri kɔlɔsili siratigɛ la. O seereyaw b’a jira ko an ka fɛn dilannen bɛ diɲɛ izini sariyaw dafa walima ka tɛmɛ u kan, o bɛ dannaya ni hakili lafiya sabati baarakɛlaw bolo baarakɛcogo suguya caman kɔnɔ.

证书 ye

Blog minnu bɛ tali kɛ o la

Aw ka to ka kuma an fɛ

Aw ka to jɛɲɔgɔnya la ni an ye walasa ka kunnafoni kuraw sɔrɔ DFUN batiri kɔlɔsili sira kan, fɛɛrɛko dɔnniyaw, ani furakɛlicogo minnu bɛ bɛn aw magow ma. An bɛ yan tuma bɛɛ ka lamɛnni kɛ ani ka dɛmɛ don.

Mob:+86- 15919182362 , Mali

E-mail: info@dfuntech.com

Aw ye Batiri Jateminɛ sɔrɔ fu

An ka BMS injiniyɛri dɔ bɛna jaabi di sanga 24 kɔnɔ.

(A bɛ se ka kɛ. Fɛɛrɛko kɔrɔtɔlenw dɔrɔn de kama)

An b’i ka gundokow bonya. I ka kunnafoniw bɛna kɛ dɔrɔn ka i ka ɲinini jaabi.

A ka baara kɛcogo ɲɛfɔra 2023 DFUN (ZHUHAI) CO., LTD. Hakɛ bɛɛ bɛ a bolo. Kunnafoni dogolenw maracogo | Sitemap (yɔrɔ karti).