Esiane sɛ nnwuma foforo renya nkɔso nti, data center adwuma no renya nkɔso ntɛmntɛm na ɛrenya nkɔso. Data centers a wɔresi no rekɔ so akɔ ultra-large scale ne ahobammɔ a ɛkorɔn so. Battery, sɛ́ ade titiriw a ɛwɔ backup power supply system a ɛwɔ data centers no mu no, di dwuma titiriw wɔ hwɛ a wɔhwɛ ma wɔde anyinam ahoɔden kɔ so na ɛyɛ adwuma sɛnea ɛsɛ wɔ bere a egye ntɛmpɛ mu no mu. Sɛnea ɛbɛyɛ a batere no bɛkɔ so ayɛ adwuma yiye no, wɔde ahobammɔ ho nhyehyɛe ho ahwehwɛde ahorow a emu yɛ den ahyɛ batere a wɔhwɛ so nhyehyɛe no so, na wɔde wɔn adwene si ahobammɔ nhyehyɛe a wɔde gyae adwumayɛ so titiriw. Saa ahobanbɔ nhyehyeɛ ahwehwɛdeɛ yi da adi titire wɔ afã mmienu mu: tumi ahobanbɔ ne nkitahodiɛ ahobanbɔ.
1. Tumi Ahobammɔ Redundancy Design
Redundancy backup design a wɔde bedi dwuma ama master device no tumi nhyehyɛe no yɛ adeyɛ titiriw ne ɔkwan titiriw a wɔfa so hwɛ hu sɛ ɛyɛ adwuma a ɛyɛ den. Sɛnea ɛbɛyɛ na wɔadi anyinam ahoɔden a entumi nyɛ yiye nanso ɛwɔ nkɛntɛnso kɛse a ebetumi aba bere a wɔreyɛ adwuma bere tenten wɔ beae hɔ no ho dwuma no, ahoɔden nhyehyɛe abien a ɛwɔ tumi nhyehyɛe a ɛwɔ master device no mu no yɛ adwuma sɛ wɔn ho wɔn ho a wɔde bɛbɔ wɔn ho wɔn ho ban, na ɛma wonya ahoɔden a wotumi de ho to so.

Ntotoho a ɛfa tumi a wɔde ma abien ne tumi a wɔde ma biako ho
2. Data a Wɔde Kɔma Ahobammɔ Redundancy Design
Wɔ batere sikakorabea dwumadie akɛseɛ mu no, nteaseɛ a ɛyɛ berɛ mu na ɛyɛ pɛpɛɛpɛ wɔ batere tebea a ɛwɔ berɛ ankasa mu wɔ berɛ a wɔresiesie daa ne ntɛmpɛ mu no ho hia. Eyi hwehwɛ sɛ wɔboaboa data ano ntɛmntɛm na wɔsan yɛ no foforo. Wɔ tebea horow a ɛtete saa mu no, network latency anaasɛ congestion betumi aba, na ɛde system no mmuae a ɛyɛ brɛoo ne data a ɛbɛsiw aba, na ɛbɛka nsiesie ne issue resolution efficiency kɛse. Dual Ethernet ports design no betumi asiw saa ɔhaw ahorow yi ano yiye, ahwɛ ahu sɛ ahyɛde a wɔde di dwuma ne data abisade nhyehyɛe no yɛ yiye.

Ethernet port abien ne Ethernet port biako a wɔde toto ho
3. Nkitahodi Ahobammɔ Redundancy Design
Wɔ bere tenten nhyehyɛe dwumadi mu, wɔ low-probability adeyɛ a cell sensor huammɔdi, ring nkitahodi nhyehyɛe betumi adi dwuma wɔ mfiridwuma mu. Saa nhyehyɛe yi yɛ nkitahodi kwan bi wɔ cell sensor ne master device no ntam, na ɛhwɛ hu sɛ cell sensor ankorankoro huammɔdi rentwitware afoforo no nkitahodi mu.

Supports ring nkitahodi, a biribiara biako point of
nkitahodi a wɔatwa a ennya ankorankoro nkwammoaa sensor nkitahodi so nkɛntɛnso
Bere a wohyia ahobammɔ a ɛkorɔn application ahwehwɛde ahorow a data center adwumayɛkuw no, ahobammɔ redundancy nhyehyɛe ayɛ ade titiriw a wosusuw ho bere nyinaa wɔ DFUN nneɛma nhyehyɛe mu. Ɛdenam nneɛma a wohu na wogyina adetɔfo nkyɛn bere nyinaa, wɔn ɛyaw nsɛm a wɔte ase yiye, na wosi so dua sɛ wɔbɛyɛ nneɛma foforo so no, . DFUN botae ne sɛ ɔbɛtua n’atɔfoɔ ahotosoɔ.