IEC 61850 DFUN batri dzi kpɔkpɔ ƒe ɖoɖo .


Le egbegbe dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si me, vevietɔ le ŋusẽdɔwɔƒea la, IEC 61850 do abe dzidzenu si dzi woda asi ɖo le xexeame katã ene. Abe ɖoɖo si me kɔ ene la, IEC 61850 ɖoa kadodo ƒe ɖoɖowo ɖe ɖoɖo nu le elektrɔnikmɔ̃ siwo me nunya le (IEDs) dome le dɔwɔƒe suewo me, si naa ɖoɖowɔɖi ƒe ƒoƒo ɖekae nyuie nɔa bɔbɔe. Woxɔe le xexeame katã ƒe ŋusẽɖoɖowo me le afisiafi, vevietɔ le ŋusẽ yeyewo abe ya kple ɣe ƒe ŋusẽ kpakple microgrid dzikpɔkpɔ me, ɖoɖo sia kpɔa egbɔ be mɔ̃ vovovowo kple mɔ̃wo ƒe dɔwɔwɔ ɖekae sesẽ.


Nukae nye IEC 61850?


IEC 61850 nye kadodo ƒe ɖoɖo si wowɔ koŋ na substation automation, si ƒe taɖodzinue nye be woado kadodo ɖe ŋgɔ le mɔ̃ siwo tso dɔwɔƒe vovovowo dome eye woado ŋusẽ ƒe ɖoɖowo ƒe dɔwɔwɔ nyuie kple kakaɖedzi ɖe edzi. Edoa alɔ ɣeyiɣi ŋutɔŋutɔ ƒe ŋkuléle ɖe nu ŋu, dziɖuɖu, kple ametakpɔkpɔ ƒe dɔwo eye wozãnɛ geɖe le ŋusẽ yeyewo ƒe agblewo abe ya kple ɣe ƒe ŋusẽ ene me, kpakple le ŋusẽ ƒe kadodo ƒe nuwo wɔwɔ le wo ɖokui si tsã me. Nu vevi ɖeka si le IEC 61850 mee nye eƒe kpekpeɖeŋu na nyatakakawo ƒe asitɔtrɔ le ɣeyiɣi ŋutɔŋutɔ me le mɔ̃wo dome to MMS (manufacturing message specification) protocol dzi, si ana ɖoɖowɔɖi ƒe ɖoɖowo, nudzɔdzɔwo ŋuti nuŋlɔɖiwo, kple dɔléle ŋuti nyatakakawo nanya.

Esi dijitaal zazã kple mɔ̃ɖaŋununya siwo me nunya le va la, IEC 61850 ƒe dzidzenua zazã va le vevie ŋutɔ. To kadodo kabakaba kple nyatakakawo mama le ɣeyiɣi ŋutɔŋutɔ me le mɔ̃wo dome dzi la, ekpena ɖe dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si ƒe ɖoɖowo ŋu be woaɖo dɔwɔwɔ nyuie kple kakaɖedzi ƒe ɖoɖo kɔkɔwo gbɔ.


DFUN batri dzi kpɔkpɔ ƒe ɖoɖo: ʋukuku nunya ƒe ŋusẽ dzikpɔkpɔ kple IEC 61850 Kpekpeɖeŋu .


DFUN PBMS9000 kple PBMS9000PRO batri dzi kpɔkpɔ ƒe ɖoɖowo naa mɔ̃ɖaŋununya ƒe kpekpeɖeŋu deŋgɔ na ŋusẽ ƒe ɖoɖo ƒe nuwo wɔwɔ le wo ɖokui si. Menye ɖeko batri dzi kpɔkpɔ ƒe ɖoɖo si me nunya le la sɔ kple IEC 61850 ƒe ɖoɖowɔɖia ko o , ke ewɔa ɖeka kple mɔ̃ vovovowo kple ɖoɖo vovovowo hã, si naa kakaɖedzi le nyatakakawo ƒe asitɔtrɔ le ɣeyiɣi ŋutɔŋutɔ me kple dɔwɔwɔ nyuie ŋu. Eɖanye na microgrids, smart grids, alo power system xoxowo o, DFUN Battery Monitoring System kpɔa egbɔ be ɖoɖoa li ke eye kakaɖedzi le eŋu to batri dzi kpɔkpɔ, edzikpɔkpɔ, kple eƒe nyonyome pɛpɛpɛ me.


DFUN PBMS9000Pro Batriwo Dzi Kpɔkpɔ ƒe Ðoɖo .


Nuɖoanyia doa alɔ kadodo ƒe ɖoɖo geɖe, siwo dometɔ aɖewoe nye IEC 61850 , si wɔnɛ be batri dzikpɔkpɔ kple dɔwɔƒe sue ƒe dɔwɔnu bubuwo wɔa dɔ aduadu kplikplikpli wu. Nuɖoanyia léa ŋku ɖe batri ƒe dzoxɔxɔ kple eƒe dodo ŋu le ɣeyiɣi ŋutɔŋutɔ me, etsɔa batri ƒe lãmesẽ ŋuti nyatakaka blibowo naa amewo, eye wòzãa mɔ̃ɖaŋununya siwo me nunya le tsɔ naa batri ƒe agbenɔƒe nyona ɖe edzi, si wɔnɛ be wòwɔa dɔ nyuie le agba ƒe nɔnɔme siwo le tɔtrɔm kabakaba me.


DFUN IED ƒe nyatakakawo ƒe kpɔɖeŋu kple dɔwɔna dzi kpɔkpɔ ƒe ŋutetewo le IedScout dɔwɔnua me .

DFUN IED ƒe nyatakakawo ƒe kpɔɖeŋu kple dɔwɔna dzi kpɔkpɔ ƒe ŋutetewo le IedScout dɔwɔnua me .


Adzɔnuwo ƒe viɖewo .


  • Nyatakakawo ƒe asitɔtrɔ nyuie: Kpekpeɖeŋu nana IEC 61850 ƒe ɖoɖowɔɖia kpɔa egbɔ be kadodo kabakaba kple kakaɖedzi le batri dzi kpɔkpɔ ƒe ɖoɖoa kple elektrikŋusẽdɔwɔƒe sue bubuwo dome.

  • Ɣeyiɣi ŋutɔŋutɔ me ŋkuléle ɖe nu ŋu kple edzikpɔkpɔ: Nyatakakawo ƒe mama le ɣeyiɣi ŋutɔŋutɔ me si wowɔ ɖekae nana ŋusẽdɔwɔlawo te ŋu wɔa nu ɖe ​​nusiwo mesɔ o ŋu kaba, si doa ŋusẽ ɖoɖoa ƒe kakaɖedzi.

  • Flexible Scalability: doa alɔ automation hiahiãwo na ŋusẽ yeyewo abe ya kple ɣe ƒe ŋusẽ, kpakple microgrid dɔwo.

  • Batriki ƒe agbenɔƒe didi: Edzia batri ƒe agbenɔƒe ɖe edzi eye wòwɔa dɔ nyuie wu to dadasɔ pɛpɛpɛ kple lãmesẽnyawo gbɔ kpɔkpɔ me.


DFGW1000 (IEC 61850 ƒe ɖoɖowɔɖi ƒe tɔtrɔ)


Nu vevi bubu si tso DFUN, DFGW1000 , nye esi wowɔ koŋ na elektrikŋusẽ ƒe xɔwo kple dɔwɔƒe suewo, si naa kpekpeɖeŋu sesẽ na ɖoɖowɔɖi ƒe tɔtrɔ kple ƒoƒo ɖekae:


DFGW1000 (IEC 61850 ƒe ɖoɖowɔɖi ƒe tɔtrɔ)


  • High-performance hardware: Wotsɔ quad-core CortexTM-A53 dɔwɔwɔ, 1GB RAM, 8GB nudzraɖoƒe, Gigabit Ethernet ʋɔtruwo, kple RS485 serial ports ɖo eŋu.

  • Nutoa me ƒe tɔtrɔ ɖe nɔnɔmewo ŋu le afisiafi:  Ewɔa dɔ nyuie le dzoxɔxɔ si tso -15°C va ɖo +60°C me, si wɔa dɔ le dɔwɔƒewo ƒe nɔnɔme sesẽwo ƒe didiwo gbɔ.

  • Protocol ƒe tɔtrɔ ƒe ŋutete: Etrɔa IEC 61850 nyuie wòzua protocol bubuwo, si wɔnɛ be mɔ̃wo dome kadodo si me kuxi aɖeke mele o.

  • Dɔ siwo wowɔna le mɔ gbadza nu: Tso ŋusẽ dzi kpɔkpɔ dzi va ɖo batriwo dzikpɔkpɔ dzi la, eƒoa eɖokui ɖe dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si ƒe hiahiã vovovowo me agbagbadzedze aɖeke manɔmee.


Nyanuwuwuw


Esi dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si yi edzi le tɔtrɔm la, akpa si IEC 61850 ƒe ɖoɖowɔɖia wɔna le ŋusẽdɔwɔƒea va le vevie wu. ƒe ƒoƒo ɖekae ƒe ŋutete deŋgɔ DFUN Battery Monitoring System naa egbɔkpɔnu siwo me nunya le wu eye kakaɖedzi le wo ŋu wu na ŋusẽ ƒe ɖoɖo vovovowo, si naa ŋusẽzazã ƒe tɔtrɔ si le dijitaal dzi la kabakaba. Eɖanye ya ƒe ŋusẽ, ɣe ƒe ŋusẽ, alo microgrid-mɔ̃woe wozãnɛ o, ɖoɖoa naa batri zazã ƒe nuteƒekpɔkpɔ nyui, si le dedie, eye kakaɖedzi le eŋu.