In » CHANCHINTHAR » Industry chanchin thar . » IEC 61850: DFUN Battery Monitoring System hmanga Power Management tha tak tihchak

IEC 61850: DFUN Battery Monitoring System hmanga Power Management tha taka tihchak

Zawhna zawt rawh

facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

IEC 61850 DFUN Battery enkawl dan tur ruahmanna siam a ni


Tunlai industrial automation-ah, a bik takin power sector-ah chuan IEC 61850 hi khawvel pum huapa hriat hlawh standard-ah a lo chhuak ta a ni. Framework kimchang tak angin IEC 61850 hian substation chhunga Intelligent Electronic Devices (IED) te inkara inbiakpawhna protocol te chu a standardize a, hei hian system integration tha tak a siamsak a ni. Khawvel pum huapa power system-a hman lar tak, a bik takin thli leh ni chakna ang chi renewable energy source bakah microgrid management-ah te hman a ni a, he protocol hian device leh system hrang hrangte inkara thawhhona nghet tak a tichiang a ni.


IEC 61850 hi eng nge ni?


IEC 61850 hi substation automation atana ruahman bik communication protocol a ni a, a tum ber chu siamtu hrang hrang atanga device hrang hrangte inkara inzawmna siam leh power system te efficiency leh rintlakna tihpun a ni. Real-time monitoring, control, leh protection functions te a support a, renewable energy field hrang hrang, thli leh ni chakna hmanga siamah te, traditional power network automation-ah te pawh hman a ni nasa hle. IEC 61850 thil pawimawh tak pakhat chu MMS (Manufacturing Message Specification) protocol hmanga device hrang hrangte inkara non-real-time data exchange a support a, configuration settings, event logs leh diagnostic information te a ti thei a ni.

Digitalization leh intelligent technology a lo chhuah tak avangin IEC 61850 standard kalpui chu a pawimawh zual hle a ni. Device hrang hrangte inkara inbiakpawhna chak tak leh real-time data sharing theihna a siam avangin industrial automation system-te chu efficiency leh rintlakna sang zawk an neih theih nan a pui a ni.


DFUN Battery Monitoring System: IEC 61850 Support hmanga Power Management fing tak khalh


DFUN PBMS9000 leh PBMS9000Pro Battery Monitoring System te hian power system automation atan technical support hmasawn tak tak a pe a ni. Intelligent battery monitoring system hi IEC 61850 protocol nen a inmil mai bakah device leh system hrang hrang nen pawh awlsam takin a inzawm a, real-time data exchange leh efficient operation a tichiang a ni. Microgrids emaw, smart grids emaw, traditional power system emaw tan pawh nise, DFUN battery monitoring system hian battery monitoring, management leh optimization dik tak hmangin system stability leh rintlakna a tichiang a ni.


DFUN PBMS9000Pro Battery enkawl dan tur ruahmanna siam a ni


He system hian communication protocol hrang hrang a support a, chung zingah chuan IEC 61850 , battery management leh substation hmanrua dangte thawhhona tha zawk a awm thei a ni. He system hian battery charge leh discharge state te chu real time-in a enfiah a, battery health report kimchang tak a pe a, intelligent algorithms hmangin battery lifespan a ti tha a, load condition inthlak chak tak hnuaiah pawh performance tha tak a siam thei a ni.


DFUN IED data model leh IEDscout tool chhunga activity monitoring theihna te

DFUN IED data model leh IEDscout tool chhunga activity monitoring theihna te


Product a thatna te


  • Data Exchange tha tak: IEC 61850 protocol support hian battery monitoring system leh substation device dangte inkara inbiakpawhna rang leh rintlak tak a siam a ni.

  • Real-Time Monitoring and Control: Integrated real-time data sharing hian power manager te chu anomalies te chu rang takin a chhang let thei a, system rintlakna a ti sang hle.

  • Flexible Scalability: Thli leh ni chakna ang chi renewable energy system-a automation mamawhna a pui a, microgrid project-ah pawh a pui bawk.

  • Extended Battery Life: Battery dam rei zawng leh hnathawh thatna a tipung a, chu chu precise balancing leh health management hmangin a tipung a ni.


DFGW1000 (IEC 61850 Protocol Converter) hmanga siam a ni.


DFUN atanga thil langsar dang, DFGW1000 , hi power utility building leh substation tan bik siam a ni a, protocol conversion leh integration atan support nghet tak a pe a ni:


DFGW1000 (IEC 61850 Protocol Converter) hmanga siam a ni.


  • High-Performance Hardware: Quad-core CortexTM-A53 processor, 1GB RAM, 8GB storage, gigabit Ethernet port, leh RS485 serial port hmanga thuam a ni.

  • Wide Environmental Adaptability:  -15°C atanga +60°C inkar temperature-ah a thawk tha hle a, industrial environment buaithlak tak takte mamawh a phuhruk thei a ni.

  • Protocol Conversion Capability: IEC 61850 chu protocol dang ah tha takin a convert a, device hrang hrang inkara inzawmna mumal tak a siam thei.

  • Broad Applications: Power monitoring atanga battery management thlengin industrial automation mamawh hrang hrangah theihtawp chhuah lovin a inzawm khawm a ni.


Tawpna


Industrial automation a lo thang zel a, chanvo chu a pawimawh zual hle. IEC 61850 protocol power sector-a -a integration theihna sang tak hian DFUN Battery Monitoring System power system hrang hrangte tan solution fing zawk leh rintlak zawk a pe a, hei hian energy management-a digital transformation a ti chak hle. Thli hmanga chakna, ni chakna, microgrid system-a hman pawh ni se, he system hian battery management experience tha tak, him tak leh rintlak tak a pe a ni.



Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 a awm a.
  +86-756-6123188 ah zawhfiah theih a ni
 tih a ni  +86- 15919182362 a ni.

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni