Le egbegbe dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si me, vevietɔ le ŋusẽdɔwɔƒewo la, IEC 61850 do abe dzidzenu si dzi woda asi ɖo le xexeame katã ene. Abe ɖoɖo si me nusianu le ene la, IEC 61850 ɖo kadodo ƒe ɖoɖowo ɖe ɖoɖo nu le Elektrɔnikmɔ̃ Siwo Ŋu Nunya Le (IED) dome le dɔwɔƒe suewo me, si wɔnɛ be ɖoɖoa ƒe ƒoƒo ɖekae nyuie nɔa bɔbɔe. Woxɔe ɖe xexeame katã ƒe ŋusẽzazã ƒe ɖoɖowo me, vevietɔ le ŋusẽ yeyewo abe ya kple ɣe ƒe ŋusẽ kpakple microgrid dzikpɔkpɔ me, ɖoɖo sia kpɔa egbɔ be mɔ̃ vovovowo kple ɖoɖo vovovowo wɔa dɔ ɖekae sesĩe.
IEC 61850 nye kadodomɔnu si wowɔ koŋ na substation automation, si ƒe taɖodzinue nye be woado kadodo ɖe ŋgɔ le mɔ̃ siwo tso dɔwɔƒe vovovowo gbɔ dome eye woana elektrikŋusẽnamɔ̃wo ƒe dɔwɔwɔ nyuie kple kakaɖedzi nanyo ɖe edzi. Edoa alɔ ɣeyiɣi ŋutɔŋutɔ me ŋkuléle ɖe nu ŋu, dziɖuɖu, kple ametakpɔkpɔ ƒe dɔwo eye wozãnɛ geɖe le ŋusẽ yeyewo abe ya kple ɣe ƒe ŋusẽ ene me, kpakple le ŋusẽ ƒe kadodo ƒe nuwo wɔwɔ le wo ɖokui si xoxo me. IEC 61850 ƒe akpa vevi ɖekae nye eƒe kpekpeɖeŋu nana nyatakaka siwo menye ɣeyiɣi ŋutɔŋutɔ o ƒe asitɔtrɔ le mɔ̃wo dome to MMS (Manufacturing Message Specification) ɖoɖowɔɖi dzi, si wɔnɛ be ɖoɖowɔɖi ƒe ɖoɖowo, nudzɔdzɔwo ŋuti nuŋlɔɖiwo, kple dɔléle ŋuti nyatakakawo te ŋu wɔa dɔ.
Esi dijitaal zazã kple mɔ̃ɖaŋununya siwo me nunya le va ta la, IEC 61850 ƒe dzidzenua dzi wɔwɔ va le vevie ŋutɔ. To kadodo kabakaba kple nyatakakawo mama le ɣeyiɣi ŋutɔŋutɔ me le mɔ̃wo dome me la, ekpena ɖe dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si ƒe ɖoɖowo ŋu be woawɔ dɔ nyuie wu eye kakaɖedzi le wo ŋu.
DFUN PBMS9000 kple PBMS9000Pro Battery Monitoring Systems naa mɔ̃ɖaŋununya ƒe kpekpeɖeŋu deŋgɔ na ŋusẽ ƒe ɖoɖo ƒe automation. Menye ɖeko batri dzi kpɔkpɔ ƒe ɖoɖo si me nunya le la wɔ ɖeka kple IEC 61850 ƒe ɖoɖowɔɖia ko o , ke ewɔa ɖeka kple mɔ̃ kple ɖoɖo vovovowo hã bɔbɔe, si wɔnɛ be nyatakakawo ɖɔliɖɔli le ɣeyiɣi ŋutɔŋutɔ me eye wowɔa dɔ nyuie. Eɖanye microgrids, smart grids, alo elektrikŋusẽ ƒe ɖoɖo xoxowo tɔ o, DFUN batri dzi kpɔkpɔ ƒe ɖoɖoa kpɔa egbɔ be ɖoɖoa li ke eye kakaɖedzi le eŋu to batri dzi kpɔkpɔ pɛpɛpɛ, edzikpɔkpɔ, kple ewɔwɔ nyuie me.

Nuɖoanyia doa alɔ kadodomɔnu geɖewo, siwo dometɔ aɖewoe nye IEC 61850 , si wɔnɛ be batri dzikpɔkpɔ kple dɔwɔƒe sue ƒe dɔwɔnu bubuwo wɔa dɔ aduadu kplikplikpli wu. Nuɖoanyia léa ŋku ɖe batri ƒe dzoxɔxɔ kple eƒe dzodzo ƒe nɔnɔme ŋu le ɣeyiɣi ŋutɔŋutɔ me, enaa batri ƒe lãmesẽ ŋuti nyatakaka blibowo, eye wòzãa mɔ̃ɖaŋununya siwo me nunya le tsɔ naa batri ƒe agbenɔƒe nanyo ɖe edzi, si wɔnɛ be ewɔa dɔ nyuie le agba ƒe nɔnɔme siwo le tɔtrɔm kabakaba me.

DFUN IED nyatakakawo ƒe kpɔɖeŋu kple dɔwɔnawo dzi kpɔkpɔ ƒe ŋutetewo le IEDscout dɔwɔnua me
Nyatakakawo Trɔtrɔ Nyuie: Kpekpeɖeŋu nana IEC 61850 ƒe ɖoɖowɔɖia kpɔa egbɔ be kadodo kabakaba eye kakaɖedzi le batri dzi kpɔkpɔ ƒe ɖoɖoa kple dɔwɔƒe sue bubuwo dome.
Ɣeyiɣi Ŋutɔŋutɔ Dzi Kpɔkpɔ Kple Edzikpɔkpɔ: Nyatakakawo mama le ɣeyiɣi ŋutɔŋutɔ me si wowɔ ɖekae nana ŋusẽdzikpɔlawo te ŋu wɔa nu kabakaba ɖe nusiwo mesɔ o ŋu, si wɔnɛ be ɖoɖoa ƒe kakaɖedzi nyona ɖe edzi.
Flexible Scalability: Doa alɔ automation hiahiãwo na ŋusẽ yeyewo ƒe ɖoɖowo abe ya kple ɣe ƒe ŋusẽ, kpakple microgrid dɔwo.
Batri ƒe Agbenɔƒe Didi: Enaa batri ƒe agbenɔƒe kple dɔwɔwɔ nyuie dzina ɖe edzi to dadasɔ pɛpɛpɛ kple lãmesẽdzikpɔkpɔ me.
Nu vevi bubu si tso DFUN gbɔ, si nye DFGW1000 , nye esi wowɔ koŋ na elektrikŋusẽdɔwɔƒewo kple elektrikŋusẽdɔwɔƒe suewo, si naa kpekpeɖeŋu sesẽ na ɖoɖowɔɖiwo ƒe tɔtrɔ kple wo ƒoƒo ƒu ɖekae:

Hardware si wɔa dɔ nyuie: Wotsɔ CortexTM-A53 processor si ƒe nu vevi ene, 1GB RAM, 8GB nudzraɖoƒe, gigabit Ethernet ports, kple RS485 serial ports ɖo eŋu.
Nutome Gãwo ƒe Trɔtrɔ Ðe Nɔnɔmewo Ŋu: Ewɔa dɔ nyuie le dzoxɔxɔ si tso -15°C va ɖo +60°C me, eye wòkpɔa dɔwɔƒewo ƒe nɔnɔme sesẽwo ƒe didiwo gbɔ.
Protocol Trɔtrɔ Ŋutete: Trɔa IEC 61850 nyuie ɖe ɖoɖowɔɖi bubuwo me, si wɔnɛ be kadodo si me kuxi aɖeke mele o le mɔ̃wo dome.
Dɔwɔwɔ Gbãtɔ: Tso ŋusẽ dzi kpɔkpɔ dzi va ɖo batri dzi kpɔkpɔ dzi la, ewɔa ɖeka kple dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si ƒe hiahiã vovovowo agbagbadzedze aɖeke manɔmee.
Esi dɔwɔƒewo ƒe nuwo wɔwɔ le wo ɖokui si yi edzi le tɔtrɔm la, akpa si IEC 61850 ƒe ɖoɖowɔɖi wɔna le ŋusẽdɔwɔƒea va le vevie wu. ƒe ƒoƒo ɖekae ƒe ŋutete gã la DFUN Battery Monitoring System naa egbɔkpɔnu siwo me nunya le wu eye kakaɖedzi le wo ŋu wu na ŋusẽ ƒe ɖoɖo vovovowo, si wɔnɛ be ŋusẽzazã ƒe tɔtrɔ le dijitaal dzi kabakaba. Eɖanye ya ƒe ŋusẽ, ɣe ƒe ŋusẽ, alo microgrid-mɔ̃wo mee wozãe le o, ɖoɖoa naa batri zazã nyuie, si le dedie, eye kakaɖedzi le eŋu.
Nusiwo Gbɔ UPS Dodokpɔ tsona Zi geɖe Kple Egbɔkpɔnu Siwo Wokafu
Battery Fire le Data Center: Alesi Nàwɔ Axe Mɔ Ðe Eŋu Kple Battery Monitoring System
Nusita Batri Dzralawo Kple Mamalawo Le Ʋuʋu Yi Smart Battery Monitoring Systems Gbɔ
Data Center Battery Fire Fia Be Hiahiã Na BMS Siwo Me Nunya Le | DFUN PBMS9000 + PBAT61 ƒe ƒuƒoƒo
Batriki Dzi Kpɔkpɔ: Ŋusẽ ƒe Dedienɔnɔ ƒe Dzogoedzikpe Le Dɔwɔƒewo Katã
Precision Meets Reliability: Le DFUN ƒe Tɔtrɔ Kpata Batri ƒe Ŋutete & Dɔwɔwɔ ƒe Dzesideɖoɖo Me
X Data Center Dzo: Nyɔnyrɔ̃ ƒe Yɔyɔ na System-Level Defenses