| Bozali: | |
|---|---|
| Motango: | |
DFPA409-100 C6 / DFPA512-100 C6 / DFPA409-100C1 / DFPA512-100 C1
DFUN ezali



-High-Rate Battery Cells (Standard): Ezali kokokisa esengelami mpo na nguya ya sauvegarde ya ntango mokuse ya miniti 10-60.
-Ebongi mpo na ba applications ya UPS na WIRE NEUTRALE mpe sans.
-Bomoi ya cycle ya ba cellules ya LiFePO4 : ≥2500 cycles na 1C taux ya charge/décharge, ≥1500 cycles na 4C décharge/0.5C taux ya charge.
-Triple Automatic Protection: Esungaka protection na ba électrodes positifs na négatifs na disjoncteur, ko assurer fidélité ya pile.
-Bopemisi moto na nivo ya PACK (Standard) mpe bopemisi moto na nivo ya armoire (Optional) mpo na bopemisi moto na bosikisiki mpe na mbangu.
-Auto-Start Function: Ezali ko permettre fonctionnement sans pilote na ko restart automatiquement après restauration ya puissance.
-Intégré Smart-Li Battery Monitoring Cloud Platform: Ezali ko assurer fonctionnement mpe entretien ya sécurité mpe efficace, kokitisa ba coûts ya opération ya mokolo na mokolo.
-Modular Design: Ezali ko simplifier installation na configuration ya mbangu; maximum ya 6 armoires en parallèle, kopesa ba options ya temps ya sauvegarde flexible.
Ndenge ya kosalela |
Puissance ya Sauvegarde ya ntango mokuse≥10 minutes |
Puissance ya Sauvegarde ya ntango molai ≥60 minutes |
||
Modèle ya Système ya Pile Li-ion |
DFPA409-100 C6. Ezali na ntina mingi |
DFPA512-100 Ezali na ntina mingi |
DFPA409-100C1. Ezali na ntina mingi |
DFPA512-100 Ezali na ntina mingi |
Capacité pona système ya UPS |
20-240KVA ezali |
20-300KVA na yango |
20-40KVA ezali |
20-50KVA na yango |
Tension ya sortie nominale (V) . |
409,6V |
512V |
409,6V |
512V |
Modèle ya Module ya Pile |
51,2V100Ah-6C ezali na kati |
51,2V100Ah-1C ezali na kati |
||
Motango ya ba Modules ya Pile (pcs) . |
8pcs ya |
10pcs na 10pcs |
8pcs ya |
10pcs na 10pcs |
Capacité ya Cluster ya pile (Ah) . |
100AH |
100AH |
||
Puissance ya Cluster ya pile (kWh) . |
40,96kWh |
51,2kWh |
40,96kWh |
51,2kWh |
Max. Courant ya Décharge Constante ya Pile |
600A |
100A |
||
Max. Puissance de décharge ya |
240kW ya |
300kW ya |
40kW ya |
50kW ya |
Equalisation ya Tension ya Charge (V) . |
441,6V |
552V |
441,6V |
552V |
Tension ya charge flottante (V) . |
435,2V |
544V |
435,2V |
544V |
Tension ya décharge ya kokata (V) . |
352V |
440V |
352V |
440V |
Interface ya bopanzi sango |
CAN/RS485/Contact ya kokauka |
|||
Bobateli |
Surcharge, Sur-décharge, Sur-temperature, Sur-courant, Court-circuit, etc. |
|||
Bolai (LxWxH) . |
600-1000-2000mm |
|||
Kilo |
Poids ya Module XN + Poids ya Armoire200 |
|||
Température ya mosala |
0-40°C (Esengami 20-25°C) |
|||