| A awm theihna: | |
|---|---|
| A zat: | |
DFPA409-100 C6 / DFPA512-100 C6 / DFPA409-100C1 / DFPA512-100 C1
DFUN a ni



-High-Rate Battery Cells (Standard): Hun rei lote chhunga backup power minute 10-60 chhunga mamawh a tlin.
-NEUTRAL WIRE nei leh nei lo UPS application atan a tha.
-LiFePO4 Cell-te Cycle Life: 1C charge/discharge rate-ah ≥2500 cycle, 4C discharge/0.5C charge rate-ah ≥1500 cycle.
-Triple Automatic Protection: Positive leh negative electrode leh circuit breaker-a venhimna a support a, battery rintlakna a tichiang.
-PACK-level kangmei venna (Standard) leh cabinet-level kangmei venna (Optional) te chu chiang leh rang taka kangmei venna atan a ni.
-Auto-Start Function: Power restoration hnuah automatic-a restart-in unmanned operation a ti thei.
-Integrated Smart-Li Battery Monitoring Cloud Platform: Hman leh enkawlna him leh tha tak a enkawl a, nitin hnathawhna senso a tihtlem phah.
-Modular Design: Setup rang tak nen installation a ti awlsam; a tam berah cabinet 6 parallel-ah a awm thei a, backup time options flexible tak a pe bawk.
Dilna |
Hun rei lote chhunga Backup Power≥10 minutes a ni |
Hun rei tak chhung Backup Power ≥60 minutes a ni |
||
Li-ion Battery System Model hmanga siam a ni |
DFPA409-100 C6 hmanga siam a ni |
DFPA512-100 C6 hmanga tihchhuah a ni |
DFPA409-100C1 hmanga siam a ni |
DFPA512-100 C1 hmanga siam a ni |
UPS system atana hman theihna |
20-240KVA thleng a ni |
20-300KVA thleng a ni |
20-40KVA thleng a ni |
20-50KVA thleng a ni |
Rated Output Voltage (V) a ni. |
409.6V a ni |
512V a ni |
409.6V a ni |
512V a ni |
Battery Module Model hmanga siam a ni |
51.2V100Ah-6C a ni |
51.2V100Ah-1C a ni |
||
Battery Module awm zat (pcs) 1.1. |
8pcs a ni |
10pcs a ni |
8pcs a ni |
10pcs a ni |
Battery Cluster awm zat (Ah) 1.1. |
100AH a ni |
100AH a ni |
||
Battery Cluster chakna (kWh) a ni. |
40.96kWh a ni |
51.2kWh a ni |
40.96kWh a ni |
51.2kWh a ni |
Max. Battery Pack atanga Discharge Current awm reng |
600A a ni |
100A a ni |
||
Max. atanga Discharge Power (kW) chu a chhuak thei lo. |
240kW a ni |
300kW a ni |
40kW a ni |
50kW a ni |
Charge Voltage (V) inthlauhna siam . |
441.6V a ni |
552V a ni |
441.6V a ni |
552V a ni |
Floating Charge Voltage (V) a ni a, a chhuahna tur hmun a awm lo. |
435.2V a ni |
544V a ni |
435.2V a ni |
544V a ni |
Cut-off Discharge Voltage (V) a ni a, a chhuahna tur hmun a awm lo. |
352V a ni |
440V a ni |
352V a ni |
440V a ni |
Inbiakpawhna Interface a ni |
CAN/RS485/Dry Contact a ni |
|||
Hriselna atana venhimna |
Overcharge, Over-discharge, Over-temperature, Over-current, Short circuit, etc. a ni. |
|||
A len zawng (LxWxH) . |
600-1000-2000mm a ni |
|||
Buk |
Module rit zawng XN + Cabinet rit zawng200 |
|||
Hnathawhna Temperature |
0-40°C (20-25°C a nih a tha) |
|||