September 26, 2025 tlai khan South Korea ram Daejeon-a Yuseong-gu-a National Information Resources Service-ah kangmei a chhuak a. Fire department-te chuan kangṭhelh hna an thawk mek a ni.



South Korea-a data center-a kangmei chhuak

Daejeon-a National Information Resources Service-a kangmei chhuak chu tualchhung kangṭhelhtute chuan an timit. (Yonhap) Thu lakna: A rilru a hah lutuk chuan a rilru a buai em em a. 10584785


Ni 26-a Hwaam-dong, Yuseong-gu, Daejeon-a National Information Resources Service-a kangmei chhuak hi darkar 10 vel hnuah a tlangpuiin thunun theih a ni.


Daejeon Fire Department leh thuneitu dangte hnen atanga ni 27-a thuchhuah tarlan danin, kangṭhelhtute chuan hemi zing dar 6:30 vel khan kangmei lian ber hi hlawhtling takin an timit thei a ni. In chhunga boruak lum tihhniam tumin meikhu lakchhuah hna an thawk a ni.


Fire department-te pawhin building chhungah hian ember la awmte endikna hnuhnung ber an nei bawk.

South Korea data center kangmei chhuak 1.jpg

Kangmei hi a hma ni zan dar 8:15 vel khan National Information Resources Service main building chhawng nga-na computer room-ah a intan a ni.


vang niin an ngai Electric hnathawh laiin lithium battery puak .


Hnathawktu zawng zawngte chu sawnchhuah vek an ni a, mahse mi pakhat chuan a hmai leh a kut ah first-degree burn a nei a ni.


Fire department hian nimin thleng hian kangṭhelhtu 171 leh fire truck 63 an dah tawh a ni .

South Korea data center-a kangmei chhuak 2

vel dah a ni a, chu chuan lithium battery 384 Computer room-ah hian meialh chu tihmit a harsa hle a , kangmei ven hna pawh zing khawvar thlengin an chhunzawm zel a ni.


Tui tam takin national resource data a tichhe thei tih ngaihtuahin, carbon dioxide leh gas kangmei venna system dangte chu hmunah hman a ni a , hei hian kangmei ven chakna a tikhawtlai a ni.


National Information Resources Service hi Korea sorkar leh tualchhung sorkarte tana IT (Information and Communication) system enkawl leh enkawltu agency a ni.

South Korea data center-a kangmei chhuak 3

Kangmei chhuak vang hian Mobile ID leh Gukmin Sinmungo ang website-te chu hmuh theih a ni lo a, sorkar department website hrang hrang leh 'Government 24' online public service platform pawh a down tawh bawk.


Tunah hian hei vang hian system 647 vel a crash nia chhut a ni.



1. South Korea Data Center Kangmei: Lithium Battery hlauhawmna tarlanna



September 26, 2025 khan South Korea khawpui Daejeon-a National Data Center-ah electric hnathawh laiin vangin kangmei a chhuak a lithium battery puak , mi pakhatin hliam na tak a tuar a, sorkar system 647 a chim bawk. Lithium battery 384 awmna hmuna dah a nih avangin kangmei ven chu a harsa hle a, darkar 10 vel zet a awh a ni. He accident hian thermal runaway risk a pholang leh a ni. temperature sang, overcharging, short circuit ang chi dinhmunah lithium battery


Lithium battery hian energy density leh size lamah hlawkna pe mahse, an himna chu data center backup power atan chuan harsatna lian tak a la ni reng a ni . A bik takin temperature sang, load tamna hmunah chuan real-time monitoring tha tak leh early warning a awm loh avangin awlsam takin kangmei a chhuak thei a ni.



2. VRLA Battery + BMS: A him tih finfiah a ni


Lithium battery nena khaikhin chuan VRLA battery hi data center, telecom base station, leh power system ang chi scenario pawimawh tak takah hun rei tak chhung chu an hmang nasa hle a, hei hi an sealed structure, leakage risk hniam, leh stability sang tak vang a ni Professional Battery Monitoring System (BMS) nen a inzawm chuan VRLA battery system hian hetiang hian a ti thei a ni:

  • Voltage, current, internal resistance, leh temperature te chu real-time-a enfiah a ni

  • Overcharge/discharge loh nan automatic balanced charging a awm thei

  • Thermal runaway a awm dawn tih hriattirna hmasa

  • State of Charge (SOC) leh State of Health (SOH) te endikna neih a ni

  • Remote alarm leh intelligent maintenance hmanga enkawl a ni


VRLA + BMS combination hi a man a tlawm zawk mai bakah kum tam tak chhunga hman a nih hnuah a him leh rintlakzia a finfiah a, hei vang hian high-standard data center tam zawk tan chuan duhthlanna duh ber a ni.



3. DFUN PBMS9000 + PBAT61: VRLA Battery atana siam Monitoring Solution kimchang tak a ni


Khawvel pum huapa battery monitoring system supplier lar tak a nih angin DFUN hian a pe a PBMS9000 system leh PBAT61 series battery cell sensors , data center atana ruahman bik , VRLA battery te chu individual cell atanga system level thlengin venhimna kimchang tak a pe a ni.


PBMS9000 System-a thil pawimawh ber berte:

  • Battery string 6 leh battery cell 480 thleng a rualin monitoring a support

  • Remote visual operation atan web server dah tel a ni

  • Voltage, current, internal resistance, temperature, insulation resistance, ripple current, etc. te chu real-time-a enfiah a ni.

  • Protocol tam tak a support a, chungte chu Modbus-TCP, SNMP, IEC61850, MQTT te an ni

  • Expandable functions te chu thermal runaway warning, liquid leakage detection, ambient temperature & humidity monitoring te a ni

  • IEEE 1188-2005 standard zawm a ni a; certification-ah hian CE, FCC, UL te pawh an tel


PBAT61 Battery Sensor a mizia te chu:

  • 2V/6V/12V VRLA battery atan a tha

  • Auto-addressing leh auto-balancing te a awm bawk

  • Cell pakhat zel voltage, a chhunga resistance, negative pole temperature te chiang taka tehna

  • Power consumption hniam design, battery dam chhung a nghawng lo

  • Ring communication topology a thlawp a; single point failure hian system kalpui dan a nghawng lo

Dfun battery enfiahna system PBAT61+PBMS9000



4. Case Studies: Khawvel pum huap Data Center-a DFUN BMS


DFUN-in battery monitoring system a siamte hi khawvel puma hmun pawimawh tak takah hlawhtling takin hman a ni tawh a, chung zingah chuan Thailand-a True IDC, Malaysia-a Intel Data Center, Qatar-a Google Data Center, Dubai-a GDH Data Center, leh Turkey-a Turkcell Data Center te pawh an tel . Hengte hian customer-te chu an battery system-te intelligent, predictive maintenance an neih theih nan a pui a , battery chhiat avanga downtime leh kangmei hlauhawmna chu a taka pumpelh theih a ni.

Data center atan Dfun BMS a awm

5. Thutawp: Data Center-te tan chuan himna hi Bottom Line a ni


South Korea data center-a kangmei chhuak hian vawi khat chu min hriat nawn tir leh a ni: backup power safety management hi ngaihthah theih a ni lo . Professional BMS nena paired proven VRLA battery thlan hi data center-te hnathawh chhunzawm zel leh him taka kalpui theihna tura pawimawh tak a ni. DFUN chuan a PBMS9000 + PBAT61 solution puitling leh rintlak tak hmangin i backup power system atan 'digital firewall' siam turin a inpeih tawh.


Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah zawhfiah theih a ni

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni