In » CHANCHINTHAR » Industry chanchin thar » Hlutna Article » Data Center-a Battery Fire: Battery Monitoring System hmanga a ven dan

Data Center-a Battery Fire: Battery Monitoring System hmanga a ven dan

Zawhna zawt rawh

facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

Tun hnaia server room-a battery kang khan thil pawimawh tak a tarlang a ni:

battery chhiat hi a thleng nghal lo — hun rei tak chhunga hlauhawm thup avanga lo awm a ni.

UPS room-ah te, telecom site-ah te, leh data center-ah te pawh enfiahna mumal tak a awm loh chuan hetiang hlauhawmna hi a awm a ni.

⚠️ Engvangin Nge Battery Kang A Awm?

1️⃣ Environment ha lo & Battery tar

Temperature sang, boruak tha lo leh leivut hian battery a ti upa chak hle.

Hun a kal zel a, battery te hian uneven internal resistance an nei , chu chuan charge laiin a lum lutuk a — thermal runaway bul tanna hmun.

DFUN Hrehawmna chinfel dan:

DFUN battery monitoring system hmang hian a hmangtute chuan:

·  enfiah thin ang che Internal resistance chu real time-ah  

·  dan track Battery temperature inthlak danglam  

·  Battery upa tawh tak takte chu hriat hmasak phawt ang che

Overheating a thlen hmain hidden risks te chu ven hmasa phawt ang che

 

2️⃣ Installation dik lo & Invenna tlakchhamna

Protection device awm lo, grounding tha lo, installation laiin monitoring awm loh chuan fault a tizual nghal vat thei a ni.

DFUN Hrehawmna chinfel dan:

DFUN systems hian hetiang hian a pe a:

·  A hun takah voltage & current enfiah a ni 

·  Thil awmdan pangngai lo a awm chuan alarm 

·  UPS / DC system awmsa nena awlsam taka inzawmkhawm theih

Ni khatna atang khan him taka hnathawh dan tur enfiah rawh

boruak lum leh vawt enfiahna.png

3️⃣ Nitin Enkawlna neih loh

Site tam tak chu kut hmanga enfiahna (manual inspection)-ah an innghat a, hetiang hian:

·  Chhungril lama invenna (resistance testing) neih a ni

·  Temperature enfiahna

·  Battery a inthlau hle

Hei hian battery inkara performance danglamna a thlen a — a chhiat chhan pawimawh tak a ni.

✅ DFUN Solution: Hriselna lama enkawl chhunzawm zel

Heng tihkhawtlai te hi hneh turin DFUN chuan remote online battery monitoring system cloud platform neiin a pe a , hei hian manual inspection atanga intelligent monitoring lama inthlak theihna a siam a ni:

·  24/7 real-time-a enfiah theih a ni Voltage, internal resistance leh temperature te

· Remote access via cloud platform , chu chuan on-site inspection neih fo a ngai tawh lo

·  automatic alarm siam thin Battery a chhiat hmaa battery pangngai lo a awm chuan

·  Data recording & trend analysis  hmanga predictive maintenance pui turin

Hei hian operator-te chu thil awmte chu a hmain a hriat theih phah a, chhanna a pe rang zawk a, battery chhiat theihna pawh nasa takin a tihziaawm thei bawk.

dfunbms(1).png tih a ni

 

Risk Tak Tak: Thermal Runaway

Battery pakhat a lum lutuk chuan:

·  Khua lumna chu a bul hnaia cell-ah a darh

·  Electrolyte a chhe vek

·  Meikhu leh kangmei a zual chak hle

He chain reaction hian battery bank pumpui a tichhia thei a ni.

Battery avanga kangmei chhuak.png

            

Kangmei a chhuak.png

Daejeon-a National Information Resources Service-a battery avanga kangmei chhuak.

Sept. 27.2025 [YONHAP] hian a rawn ti a.

Global Switch-a London data center-ah kangmei a chhuak a ni

Jan. 26. 2026 khan a lo piang a.

 

✅ DFUN Battery Monitoring System-in a puih dan

DFUN hian kimchang tak a pe a battery monitoring solution  , chungte chu:

·  Data center hrang hrang a awm

·  UPS system hrang hrangte

·  Telecom base station hrang hrang a awm

Thil pawimawh tak takte chu:

·   A hun takah enfiah  (voltage, current, resistance, temperature) .

·  A hmaa hriattirna alarm 

·   Hmun hla tak atanga enkawl & centralized management 

·  Battery string a inthlauhna (balancing) a ni

·   SOC&SOH Chhiar dan

Maintenance chu passive → proactive atanga thlak danglam

bmscase.png tih a ni

Tawpna

Battery accident hi ven theih a ni.

rintlak tak kalpuiin Battery monitoring system , operator-te chuan:

·  Risk awm thei te chu hriat hmasak

·  Enkawlna senso tihtlem

·  Hlawhchhamna nasa tak thleng thei lo tur pumpelh

Critical power system-ah chuan recovery aiin prevention hi a hlu zawk fo thin.

 

Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah zawhfiah theih a ni

A thuneihna chu 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni