A ziaktu: Site Editor Thuchhuah Hun: 2025-05-22 A chhuahna hmun: Hmun
Energy dahkhawlna atana thil pawimawh ber pakhat atan data center, communication base station, rel hmanga kal leh field dang dangah te battery hman a ni nasa hle. Mahse, swelling issues hian bomb thup angin hna a thawk a—mild cases battery lifespan a ti tawi a, case na tak tak emaw chuan kangmei emaw puak emaw pawh a thlen thei! Engtin nge 24/7 real-time monitoring leh proactive protection hi a awm theih ang? DFUN Battery Monitoring System (BMS) hian a rilru a hneh hle a, a taksa pawh a hlim hle a ni!
I. Battery swelling thlentu thihna thlen thei & DFUN solutions te
1.Overcharge/overdischarge – enkawl dan dik tak, Dynamic adjustment
A chhan: Charging current tam lutuk emaw, hun rei tak charging emaw hian internal gas buildup a thlen thin.
DFUN solution:
Real-time monitoring: PBMS 9000 series hian cell tin voltage, current, temperature, SoC/SOH te dik takin a enfiah a, anomalies te tan instant alarm a trigger a ni.
Online equalization: Cell hrang hrang inkara voltage danglamna chu automatic-in a balance a, chu chuan single-cell overcharging a veng thei a ni.
2.Plate sulfation – chhungril lama dodalna thlirletna, vaukhânna hmasa.
A chhan: Sulfation hian a chhunga resistance a tipung a, heat generation a ti chak zawk.
DFUN solution:
Impedance detection: PBAT 71/PBAT 81 Sensors hian a chhunga resistance chu a hun takah a teh thin. DFCS 4200 system nen an khaikhin chuan degradation trends an zirchiang a, maintenance recommendation an siam bawk.
3.Thermal Runaway – Multi-dimensional temperature control .
A chhan: Electrolyte a vawt emaw, a chhehvel boruak lum lutuk emaw chuan thermal runaway a thlen thei.
DFUN solution:
Dual-temperature enkawl dan: Battery chhunga battery temperature (negative pole) + ambient temperature/humidity (optional H-THD sensor), -20°C atanga 85°C (±0.5°C) inkar a ni.
Thermal Runaway Monitoring: Temperature + voltage, intercepting temperature sang leh differentials te dual monitoring—DFUN BMS hian thermal runaway chain reaction te chu click khat lek hmangin a block thin.
Thermal Spread Prevention: PBMS 9000 Pro hian optional hydrogen sensor (0-1000ppm) leh insulation resistance monitoring (1KΩ~30MΩ) te a thlawp a, hei hian puak thei thil a ti bo thei a ni.
4.Vent blockage – hmuh theiha dinhmun, hmun hla taka enkawlna
A chhan: Blocked vents avanga gas awmkhawm.
DFUN solution:
Thâwkna êng design: PBAT 61 Sensors LED rawng hmanga hrisêlna dinhmun a lantîr (green/red). Multi-channel alerts (APP/SMS/Email) chu thil dik lo a awm chuan a trigger a.
II a ni. DFUN BMS: 'reactive response' atanga 'proactive venhimna' thlengin
Full-Scenario-a coverage a awm bawk.
Hmun tenau : PBMS 2000 (cell 120), Modbus/SNMP protocol thlawptu economical solution.
Data center lian : PBMS 9000 (420 cells) hian IEC61850/MQTT a thlawp a, high-frequency environment pawh a thlawp bawk.
Harsh industrial scenario : PBMS9000PRO (chemical plants/substations) UL/CE-certified, IP65-rated leh anti-interference design a ni.
Smart maintenance system 1000 a ni.
Cloud Management : DFCS 4200 Platform hian battery 100,000+, kum 5 chhunga data dahkhawmna, leh one-click CSV report export-te centralized monitoring a thlawp a ni.
Mobile thawhhona : HMI touchscreen emaw mobile app hmanga hla taka hnathawh, real-time historical curve leh fault diagnostics hmanga hnathawh.
Predictive maintenance .
AI prediction : Multi-parameter fusion algorithms (impedance, temperature, voltage) hian battery a chhiat theihna tur ni 30 chhunga a hmaa hriattirna a pe thei.
Case Validation : Thailand-a IDC dik tak IDC leh Saudi Aramco oil field-a high-pressure scenario-a hlawhtling taka deploy a, failure rate 90%-a tihhniam.
iii a ni. User Benefits: Hriselna + sum senso tihtlem .
✅ Safety : 24/7 Monitoring + multi-level alerts, swelling chain reaction a awm loh nan.
✅ Cost Savings : Manual inspection chu 60% in tihtlem la, battery lifespan chu kum 2-3 in tizau rawh.
✅ Compliance : Khawvel pum huap tehfung a tlin a, IEEE 1188 leh ISO9001 te pawh a huam tel.
Tunah hian hma la rawh :
Visit . www.dfuntech.com emaw biak theih emaw a ni. info@dfuntech.com A thlawna customized solution atan!
DFUN Tech – Battery tinte nunna kawng humhalh turin technology chakna pek!
Battery swelling crisis a awm em? DFUN BMS Smart Guard, invenna hmasa ber!
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte