In » CHANCHINTHAR » Industry chanchin thar . » Battery swelling crisis a awm em? DFUN BMS Smart Guard, invenna hmasa ber!

Battery swelling crisis a awm em? DFUN BMS Smart Guard, invenna hmasa ber!

A ziaktu: Site Editor Thuchhuah Hun: 2025-05-22 A chhuahna hmun: Hmun

zawhna zawt rawh .

Facebook Sharing button a awm bawk.
Twitter atanga Sharing button a awm bawk.
Line Sharing button a awm bawk.
WeChat hmanga Sharing tih a ni.
LinkedIn Sharing button a awm bawk.
Pinterest hmanga Sharing tih a ni.
WhatsApp Sharing button 1000 a awm bawk.
ShareHe Sharing button hi a awm em?

Energy dahkhawlna atana thil pawimawh ber pakhat atan data center, communication base station, rel hmanga kal leh field dang dangah te battery hman a ni nasa hle. Mahse, swelling issues hian bomb thup angin hna a thawk a—mild cases battery lifespan a ti tawi a, case na tak tak emaw chuan kangmei emaw puak emaw pawh a thlen thei! Engtin nge 24/7 real-time monitoring leh proactive protection hi a awm theih ang? DFUN Battery Monitoring System (BMS) hian a rilru a hneh hle a, a taksa pawh a hlim hle a ni!


I. Battery swelling thlentu thihna thlen thei & DFUN solutions te

1.Overcharge/overdischarge – enkawl dan dik tak, Dynamic adjustment


               A chhan: Charging current tam lutuk emaw, hun rei tak charging emaw hian internal gas buildup a thlen thin.

    • DFUN solution:

      • Real-time monitoring: PBMS 9000 series hian cell tin voltage, current, temperature, SoC/SOH te dik takin a enfiah a, anomalies te tan instant alarm a trigger a ni.

      • Online equalization: Cell hrang hrang inkara voltage danglamna chu automatic-in a balance a, chu chuan single-cell overcharging a veng thei a ni.


Battery a awm bawk.

  2.Plate sulfation – chhungril lama dodalna thlirletna, vaukhânna hmasa.

    • A chhan: Sulfation hian a chhunga resistance a tipung a, heat generation a ti chak zawk.

    • DFUN solution:

      • Impedance detection: PBAT 71/PBAT 81 Sensors hian a chhunga resistance chu a hun takah a teh thin. DFCS 4200 system nen an khaikhin chuan degradation trends an zirchiang a, maintenance recommendation an siam bawk.

  3.Thermal Runaway – Multi-dimensional temperature control .

    • A chhan: Electrolyte a vawt emaw, a chhehvel boruak lum lutuk emaw chuan thermal runaway a thlen thei.

    • DFUN solution:

      • Dual-temperature enkawl dan: Battery chhunga battery temperature (negative pole) + ambient temperature/humidity (optional H-THD sensor), -20°C atanga 85°C (±0.5°C) inkar a ni.

      • Thermal Runaway Monitoring: Temperature + voltage, intercepting temperature sang leh differentials te dual monitoring—DFUN BMS hian thermal runaway chain reaction te chu click khat lek hmangin a block thin.

      • Thermal Spread Prevention: PBMS 9000 Pro hian optional hydrogen sensor (0-1000ppm) leh insulation resistance monitoring (1KΩ~30MΩ) te a thlawp a, hei hian puak thei thil a ti bo thei a ni.

Battery kah a ni .

 4.Vent blockage – hmuh theiha dinhmun, hmun hla taka enkawlna

    • A chhan: Blocked vents avanga gas awmkhawm.

    • DFUN solution:

      • Thâwkna êng design: PBAT 61 Sensors LED rawng hmanga hrisêlna dinhmun a lantîr (green/red). Multi-channel alerts (APP/SMS/Email) chu thil dik lo a awm chuan a trigger a.

Battery enkawl dan System Case Study .

II a ni. DFUN BMS: 'reactive response' atanga 'proactive venhimna' thlengin

  1. Full-Scenario-a coverage a awm bawk.

    • Hmun tenau : PBMS 2000 (cell 120), Modbus/SNMP protocol thlawptu economical solution.

    • Data center lian : PBMS 9000 (420 cells) hian IEC61850/MQTT a thlawp a, high-frequency environment pawh a thlawp bawk.

    • Harsh industrial scenario : PBMS9000PRO (chemical plants/substations) UL/CE-certified, IP65-rated leh anti-interference design a ni.

  2. Smart maintenance system 1000 a ni.

    • Cloud Management : DFCS 4200 Platform hian battery 100,000+, kum 5 chhunga data dahkhawmna, leh one-click CSV report export-te centralized monitoring a thlawp a ni.

    • Mobile thawhhona : HMI touchscreen emaw mobile app hmanga hla taka hnathawh, real-time historical curve leh fault diagnostics hmanga hnathawh.

  3. Predictive maintenance .

    • AI prediction : Multi-parameter fusion algorithms (impedance, temperature, voltage) hian battery a chhiat theihna tur ni 30 chhunga a hmaa hriattirna a pe thei.

    • Case Validation : Thailand-a IDC dik tak IDC leh Saudi Aramco oil field-a high-pressure scenario-a hlawhtling taka deploy a, failure rate 90%-a tihhniam.

Battery enkawl dan System Case Zirna2.


iii a ni. User Benefits: Hriselna + sum senso tihtlem .

Safety : 24/7 Monitoring + multi-level alerts, swelling chain reaction a awm loh nan.
Cost Savings : Manual inspection chu 60% in tihtlem la, battery lifespan chu kum 2-3 in tizau rawh.
Compliance : Khawvel pum huap tehfung a tlin a, IEEE 1188 leh ISO9001 te pawh a huam tel.


Tunah hian hma la rawh :
Visit . www.dfuntech.com emaw biak theih emaw a ni. info@dfuntech.com A thlawna customized solution atan!

DFUN Tech – Battery tinte nunna kawng humhalh turin technology chakna pek!



Kan inzawmna .

Product category 10 a awm bawk.

Quick Links .

Kan rawn biak theih reng e

   +86-15919182362==
  +86-756-6123188 ah a awm.
 chuan .  +86-15919182362= a ni.

A rilru a buai em em a, a rilru a hah em em 2023 bawk a. DFUN (Zhuhai) Co., Ltd. Thuneihna zawng zawng a nei. Privacy policy 1.1. | Sitemap 100 a ni.