Uninterruptible Power Supply (UPS) ram chhungah chuan, heng system pawimawh tak takte rintlak leh dam rei theihna tur atan UPS hlawhchhamna thlentu thilte hriatthiamna chu a pawimawh ber a ni.
A UPS system hi a tlangpuiin key component engemaw zat a awm a, chu chuan power tihtawp loh a pe thei a ni:
· Rectifier: Input source atanga AC power chu DC power ah a chantir a, chu chu battery charge nan leh inverter-a supply power supply nan hman a ni.
· Battery: Electrical energy chu battery, flywheel, emaw supercapacitor hmangin a dah a, chu chuan power tihtawp loh a pe thei a ni.
· Inverter: DC power chu AC power-ah a chantir a, chu chuan electric connected device-ah a kal zel a, a kal zel a ni.
· Static Bypass: UPS hian a hlawhchham emaw, a enkawl emaw a nih chuan a hnathawh dan pangngai chu a bypass thei a ni.
UPS system eng pawh thinlung chu a battery-ah a awm a; Power outage-a chhunzawm zel theihna tur nunna kawng (lifeline) an ni. Mahse, heng vital components te hi a enkawl tha lo emaw, enkawl tha lo emaw a nih chuan hlawhchhamna nasa ber an ni bawk. UPS system hlawhchham chhan tlangpui thenkhat chu han thlir ila:
· Maintenance tha lo: Battery te hian a tha thei ang bera an thawh theih nan check leh maintenance mumal tak neih a ngai thin. Hei hi ngaihthah chuan vulcanization a thlen thei a, chutah chuan lead sulfate crystals chu battery plate-ah a pung khawm a, performance a tikhawlo thei a ni.
· Environmental factors: UPS system kalpui danah hian ambient temperature hian hmun pawimawh tak a chang a. Temperature sang lutuk hian UPS system leh equipment downtime a ti lum lutuk a, kangmei leh himna atana hlauhawm dang pawh a thlen thei a, chutih laiin battery nun leh hnathawh a nghawng thei bawk.
· Overcharging/undercharging: Scenario pahnih hi a chhiat phah hle. Overcharging hian electrolyte chhunga tui chu electrolyze-in a siam duh a, gas a siam a, battery a ti bulge a, undercharging-ah chuan vulcanization a awm bawk.
· Capacitor failure: Capacitor hi voltage inthlak danglamna smooth out nan leh UPS atanga output nghet tak neih theihna turin a pawimawh hle. An hlawhchham chuan UPS system performance an tichhe thei a ni. Battery ang bawkin capacitor te hi hun kal zelah an chhe vek a, a tlangpuiin kum 7-10 chhung an dam chhung an nei thin.
Heng harsatnate dona tur leh UPS system-a dam rei zawng tihtawp tur chuan pawl hrang hrangte chuan:
· Maintenance check reng reng: I UPS system leh battery te tan harsatna hmasa ber awm thei tur chu man theih turin routine inspection leh maintenance te chu schedule rawh.
· Environmental Control: I UPS chu battery hriselna atana tha tak, controlled temperature leh humidity level nei environment-ah dah a nih theih nan enfiah rawh.
· Staff te zirtirna: UPS system leh battery life tichhe thei thil hrang hrang hriat theihna tur leh awareness chungchanga enkawlna tha tak nei te zirtir.
A chunga heng thiltih te hi pawm hian beisei loh power tihbuai avanga critical operations te chu a humhim thei a ni. Mahse, manual, regular maintenance leh inspection te hi hun khawhralna leh hnathawh tamna mai ni lovin tihsual awm thei te pawh a ni. a hmasa berah chuan technology hmasawn tak tak te chu hman a tha hle ang. DFUN BMS solution , leh enterprise te chuan destructive UPS hlawhchhamna an tawh theihna tur chu nasa takin a tihziaawm thei a ni. Online real-time monitoring atan
x Data Center kangmei: System-level defenses te tan a harh chhuahna a ni.
Battery swelling crisis a awm em? DFUN BMS Smart Guard, invenna hmasa ber!
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai