A ziaktu: Site Editor Thuchhuah Hun: 2024-04-29 A chhuahna hmun: Hmun
Uninterruptible Power Supply (UPS) ram chhungah chuan, heng system pawimawh tak takte rintlak leh dam rei theihna tur atan UPS hlawhchhamna thlentu thilte hriatthiamna chu a pawimawh ber a ni.
A UPS system hi a tlangpuiin key component engemaw zat a awm a, chu chuan power tihtawp loh a pe thei a ni:
· Rectifier: Input source atanga AC power chu DC power ah a chantir a, chu chu battery charge nan leh inverter-a supply power supply nan hman a ni.
· Battery: Electrical energy chu battery, flywheel, emaw supercapacitor hmangin a dah a, chu chuan power tihtawp loh a pe thei a ni.
· Inverter: DC power chu AC power-ah a chantir a, chu chuan electric connected device-ah a kal zel a, a kal zel a ni.
· Static Bypass: UPS hian a hlawhchham emaw, a enkawl emaw a nih chuan a hnathawh dan pangngai chu a bypass thei a ni.
UPS system eng pawh thinlung chu a battery-ah a awm a; Power outage-a chhunzawm zel theihna tur nunna kawng (lifeline) an ni. Mahse, heng vital components te hi a enkawl tha lo emaw, enkawl tha lo emaw a nih chuan hlawhchhamna nasa ber an ni bawk. UPS system hlawhchham chhan tlangpui thenkhat chu han thlir ila:
· Maintenance tha lo: Battery te hian a tha thei ang bera an thawh theih nan check leh maintenance mumal tak neih a ngai thin. Hei hi ngaihthah chuan vulcanization a thlen thei a, chutah chuan lead sulfate crystals chu battery plate-ah a pung khawm a, performance a tikhawlo thei a ni.
· Environmental factors: UPS system kalpui danah hian ambient temperature hian hmun pawimawh tak a chang a. Temperature sang lutuk hian UPS system leh equipment downtime a ti lum lutuk a, kangmei leh himna atana hlauhawm dang pawh a thlen thei a, chutih laiin battery nun leh hnathawh a nghawng thei bawk.
· Overcharging/undercharging: Scenario pahnih hi a chhiat phah hle. Overcharging hian electrolyte chhunga tui chu electrolyze-in a siam duh a, gas a siam a, battery a ti bulge a, undercharging-ah chuan vulcanization a awm bawk.
· Capacitor failure: Capacitor hi voltage inthlak danglamna smooth out nan leh UPS atanga output nghet tak neih theihna turin a pawimawh hle. An hlawhchham chuan UPS system performance an tichhe thei a ni. Battery ang bawkin capacitor te hi hun kal zelah an chhe vek a, a tlangpuiin kum 7-10 chhung an dam chhung an nei thin.
Heng harsatnate dona tur leh UPS system-a dam rei zawng tihtawp tur chuan pawl hrang hrangte chuan:
· Maintenance check reng reng: I UPS system leh battery te tan harsatna hmasa ber awm thei tur chu man theih turin routine inspection leh maintenance te chu schedule rawh.
· Environmental Control: I UPS chu battery hriselna atana tha tak, controlled temperature leh humidity level nei environment-ah dah a nih theih nan enfiah rawh.
· Staff te zirtirna: UPS system leh battery life tichhe thei thil hrang hrang hriat theihna tur leh awareness chungchanga enkawlna tha tak nei te zirtir.
A chunga heng thiltih te hi pawm hian beisei loh power tihbuai avanga critical operations te chu a humhim thei a ni. Mahse, manual, regular maintenance leh inspection te hi hun khawhralna leh hnathawh tamna mai ni lovin tihsual awm thei te pawh a ni. a hmasa berah chuan technology hmasawn tak tak te chu hman a tha hle ang. DFUN BMS solution , leh enterprise te chuan destructive UPS hlawhchhamna an tawh theihna tur chu nasa takin a tihziaawm thei a ni. Online real-time monitoring atan
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .