DFCS4100 a ni
DFUN a ni

DFCS4100 Bms Battery Management System hi SCADA system a ni a, platform a inhawng kim vek a, all-round running a nei bawk. UPS, battery string leh server room environment zawng zawnga status leh control settings enfiah tura tumruh taka siam user interface a ni. He system hian function hrang hrang real-time data collection, historical data checking, report generating, real-time alert etc. hmangin implement a ni a, system dang nena inbiakpawhna atan standard interface hmanga siam a ni bawk.
He management system hian input/output parameters, backup time leh UPS status te chu remote atangin a teh thei a, a monitor thei a, a adjust thei a, a control thei bawk. He system hian network communication technology hmangin battery string emaw battery pakhat voltage emaw, charge leh discharge current, internal resistance, temperature, SOC, SOH te pawh a enfiah thei a, data a khawlkhawm thei bawk.
Monitoring hnuaia awm battery leh battery string te real time status chungchangah feedback a pe thei a ni. Hetihlai hian administrator-in battery string hriselna dinhmun a enfiah theihna tur chu historical data hman dan rintlak tak hmangin a tipung a ni.
He system hian micro service framework a hmang a, dynamic capacity expansion leh database cluster a support a ni. System-a core function chu user tan visualized data exchange interface a pe a ni. System module design nan hian classic MVC framework hman a ni tawh bawk. System front-end hian MVVM structure hmangin system leh user interface atanga data te chu a decouple a ni. System-in real time data a lantir laiin efficient rate leh transmission performance rate tihsan nan front-end data exchange technology chuan WebSocket hmangin server atanga browser dangah data a lantir theih nan a hmang a ni.

Real-Time Monitoring: A hun takah status enfiah leh data khawlkhawm. All-round atanga diagram leh chart hmanga real time status leh tendency lantir mai bakah, channel device leh monitoring device ang chi secondary equipment dinhmun enfiah bawk.
Historical Data Management: Device run data history enfiah te, charge leh discharge record zawh te, monitoring event log enfiah te.
Real-Time Alert: A hun takah information tarlan leh device alarm nemnghehna.
Report Printing: Malfunction analysis, battery leh battery string data analysis te report print chhuak thin.
Event Log: User login, operation leh system hun bituk chhunga kalpui dan tur log entir.
User Access Rights: System-a user access rights enkawl dan tur
Parameter Configuration: Information settings bulpui te enkawl rawh
Data Exchange: Web Service leh MODBUS TCP interface te pe rawh
Alarm Notification: SMS, E-mail leh tele phone alarm te a support
Remote Controlling: PBMS series product settings te chu control theih a ni.