A ziaktu: Site Editor Thuchhuah Hun: 2024-08-06 A chhuahna hmun: Hmun
Uninterruptible Power Supply (UPS) system hi power tlakchham laia critical system-te hnena power chhunzawm zel theihna tura pawimawh tak a ni. Heng system-te bulpuiah hian chakna mamawh dahna battery-te chu a awm a ni. UPS battery chi hrang hrang hriatthiamna hi i mamawhna atana duhthlan tur tha ber thlan nan a pawimawh hle.
hrilhfiahna leh chi hrang hrang .
UPS system-a hman tlanglawn ber pakhat chu lead-acid battery hi a ni. A chi hnih a awm a, chungte chu valve regulated lead acid (VRLA) leh vented lead acid (VLA) te an ni. VRLA battery te chu sealed a ni a, chu chu a chhuah theihna tur gas vent tu case-ah valve an nei a, direct maintenance tlemte chauh a ngai a ni. VLA battery erawh chu sealed a ni lo va, chuvangin hydrogen gas siam chhuah eng pawh chu direct-in environment-ah a tlanchhuak thei a ni. Hei hian VLA battery hmanga installation-ah chuan ventilation system nghet zawk a ngai tihna a ni.
Nihphung
Lead-acid battery hi a rintlak leh a man tlawm avangin hriat hlawh tak a ni. Power output nghet tak an pe a, enkawl a awlsam hle a, a bik takin VRLA type an ni. Mahse, an bulky a, an rit bawk a, chu chu space leh weight ngaihtuahnaa hmanna hmuna harsatna a ni thei. Tin, an dam rei zawng hi battery chi dang thenkhat nen khaikhin chuan a tawi zawk bawk.
Service nun leh hman dan tur scenario .
Lead-acid battery service life tlangpui chu kum 5 atanga kum 10 inkar a ni a, hman dan leh enkawl dan azirin a ni. Data center, emergency lighting, leh telecommunications system-ah te an hman tlangpui a, an rintlak leh an man tlawm zawk avangin an hmang nasa hle.
Storage environment mamawh leh man .
Lead-acid battery te hi an dam rei theihna tur hmun lum leh vawt takah dah a ngai a ni. An man tlawm deuh a, hei vang hian UPS application tam takah chuan duhthlanna lar tak an ni. Mahse, lead content avanga an environment impact chuan disposal leh recycling dik tak a mamawh a ni.
Hrilhfiahna
Nickel-cadmium (NI-CD) battery hi UPS system-a hman tur dang a ni bawk. Heng battery te hian nickel oxide hydroxide leh metallic cadmium te chu electrode atan an hmang thin.
Nihphung
NI-CD battery te hi an robustness leh an perform tha thei em em a, temperature nasa takah an che tha hle. Lead-acid battery aiin dam rei zawk an nei a, deep discharges an tuar thei a, capacity hloh nasa tak an nei lo. A chhe lam chuan an man a to zawk a, toxic cadmium leh nickel awm zat avang hian environment impact an nei sang zawk bawk.
Service nun leh hman dan tur scenario .
NI-CD battery service life hi enkawl dan tur dik tak nen kum 20 thleng a ni thei. Anni hi boruak khirh tak tak leh hmanna pawimawh tak takah hman atan an tha hle a, rintlakna chu a pawimawh ber a ni a, chu chu UPS hmanna hmun, a bik takin Middle East-a boruak lumna sang tak awmna hmunah te, telecoms industry-ah te pawh a ni.
Storage environment mamawh leh man .
NI-CD battery te hi an dam rei theihna tur atan boruak vawt, moderate-temperature-ah dah tur a ni. An initial cost sang zawk chu an durability leh long service life avang hian a offset a, hei hian cadmium leh nickel toxicity avanga uluk taka paih chhuah a ngaih laiin hun rei tak chhung atan cost-effective option a ni.
Hrilhfiahna
UPS system-ah hian lithium-ion (li-ion) battery hi a lar chho zel a, hei hi energy density sang tak leh efficiency sang tak avang a ni. Heng battery te hian lithium compound te chu electrode material atan an hmang thin.
Nihphung
Li-ion battery hi a rit lo va, a tlem hle a, energy density sang tak a pe a, hei hian hmun a tlemna hmuna hmanna atan a tha hle. An dam rei zawk a, lead-acid battery nena khaikhin chuan enkawlna an mamawh tlem zawk. Mahse, an man a to zawk thung.
Service nun leh hman dan tur scenario .
UPS system leh energy storage system dang, renewable energy technology atanga power hmanga thlipui emaw, ni emaw ang chi hmanga hman thin an ni.
Storage environment mamawh leh man .
Li-ion battery te hi hmun lum leh vawt takah dah tur a ni a, chutiang chuan an dam rei theihna tur leh an himna tur a ni. An sum senso sang zawk chu a dal thei a, mahse an efficiency leh an dam rei zawk chuan hun kal zelah investment chu a tidik thei a ni.
DFUN hian UPS battery mamawh hrang hrang tan tailored solution a pe a, hei hian performance leh dam rei theihna tur a siamsak a ni. Tan Lead-acid leh Ni-CD battery , DFUN hian health monitoring solutions kimchang tak a pe a, chu chuan data, battery voltage, charging/discharging current, SOC leh SOH te a enfiah a, battery activation, battery balancing, leh alarm te pawh a huam tel bawk. DFUN Backup Power Monitoring System hian UPS power system leh lithium-ion battery-te centralized monitoring a pe a, hei hian hmun hrang hranga power source leh lithium-ion battery hrang hrang sem darh chu cross-regional-in a enkawl thei a ni.
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
Dfun Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .