Zotsatira za Zidebe: Kuchuluka kwa madzi omwe chidebe chingatenge kumadalira chibonga chake chachifupi kwambiri.
Pamalo a mabatire, Mphamvu ya Zidebe imawonedwa: Kuchita kwa paketi ya batri kumadalira selo lomwe lili ndi magetsi otsika kwambiri. Kusanja kwa voteji kumakhala koyipa, chodabwitsa chimachitika kuti batire imayendetsedwa pakanthawi kochepa.
Njira Yachikhalidwe:
Kuyang'ana pamanja nthawi ndi nthawi kuti muzindikire mabatire omwe ali ndi voteji yocheperako komanso mabatire omwe ali ndi mphamvu zochepa.
Njira Yanzeru:
BMS (Battery Management System) ili ndi ntchito yoyanjanitsa yokha yomwe imatha kusanja ma voltage panthawi yolipirira ndi kutulutsa.
Kusanja mokhazikika kumaphatikizanso kuchitapo kanthu komanso kusakhazikika.
Kusamutsa kokhazikika kumaphatikizapo kutengera potengera ndalama komanso kusamutsa motengera mphamvu.
Kulinganiza kumachitika ndi kusamutsidwa kopanda kutaya kwa mphamvu, mwachitsanzo, mphamvu imasamutsidwa kuchokera ku maselo omwe ali ndi magetsi apamwamba kupita kwa omwe ali ndi magetsi otsika, kukwaniritsa mphamvu zonse zamagetsi ndi kutaya mphamvu zochepa; motero, amatchedwanso kusataya kutaya.
Ubwino: Kutaya mphamvu pang'ono, kuchita bwino kwambiri, nthawi yayitali, kutsika kwambiri, kuchitapo kanthu mwachangu.
Zoipa: Zozungulira zovuta, zokwera mtengo.

Pali gawo lamagetsi la DC / DC mkati mwa sensa iliyonse yowunikira. Pakuthamangitsa zoyandama, gawoli limalipiritsa selo ndi voteji yotsika kwambiri kuti ionjezere mtengo wake mpaka ifike pamlingo wokhazikika.
Ubwino wake: Kulipiritsa molunjika kwa ma cell ocheperako kapena osachita bwino kwambiri.
Zoipa: Mtengo wokwera chifukwa cha kufunikira kwa ma modules amagetsi a DC / DC, chiopsezo chowonjezera (chotheka ndi kuganiziridwa molakwika), mtengo wapamwamba wokonzekera chifukwa cha kulephera komwe kungatheke.

Kusanjikiza kosalekeza nthawi zambiri kumaphatikizapo kutulutsa ma cell amagetsi okwera kudzera m'ma resistors, kutulutsa mphamvu mu mawonekedwe a kutentha kuti akwaniritse voteji yonse, motero amalola ma cell ena kuti azilipira nthawi yolipirira.
Ubwino: Kutulutsa kochepa kwamakono, teknoloji yodalirika, yotsika mtengo.
Zoipa: Nthawi yotulutsa yochepa, mphamvu yapang'onopang'ono.

Mwachidule, BMS yamakono ya mabatire a lead-acid nthawi zambiri imagwiritsa ntchito kusanja mokhazikika. M'tsogolomu, Dfun idzayambitsa ma hybrid balancing, omwe amalinganiza ma cell-voltage apamwamba kudzera mu ma cell otulutsa ndi otsika kwambiri kudzera pa charger.
Zomwe Zimayambitsa Kulephera kwa UPS ndi Mayankho Olangizidwa
Moto wa Battery mu Data Center: Momwe Mungapewere ndi Battery Monitoring System
Chifukwa Chake Opanga Ma Battery Ndi Ogawa Akusunthira Kuma Smart Battery Monitoring Systems
Data Center Battery Fire Shows Kufunika kwa Intelligent BMS | DFUN PBMS9000 + PBAT61
Voltage Yapano & Ripple - Opha Mabatire Obisika, Ndi Momwe DFUN PBMS9000 Imatetezera Mphamvu Yanu
Kuyang'anira Battery: Mwala Wapangodya wa Chitetezo cha Mphamvu Pamakampani Onse
X Data Center Fire: Kuyimba Kwake kwa Chitetezo cha System-Level