tupian1

Sisiteme yo Langutisisa Betiri

Kaya Sisiteme yo Langutisisa Betiri

Xana Sisiteme yo Langutisisa Betiri (BMS) i yini?

Sisiteme yo Langutisisa Betiri (BMS) i pulatifomo yo tlhariha leyi endleriweke ku tshama yi ri karhi yi langutisisa, ku kambisisa na ku sirhelela tisisiteme ta betri leti tirhisiwaka eka tindhawu leti nga na nkoka wa vurhumiwa. BMS ya xiyimo xa le henhla—DFUN Battery Monitoring System—yi landzelela matirhelo ya betri hi nkarhi wa xiviri eka xiyimo xa tintambhu na xiyimo xa sele yin’wana na yin’wana, yi pfuna tinhlengeletano ku sivela ku tsandzeka, ku engetela vutomi bya betri, na ku hlayisa ku tshembheka ka gezi.


Sisiteme yi pima tipharamitha ta nkoka to fana na voltage, current, temperature, internal resistance (IR), ripple, SOC (Xiyimo xa Charge), SOH (Xiyimo xa Rihanyo), na SOP (Xiyimo xa Matimba). Hi tialamu to vhumbha leti akiweke endzeni, nxopaxopo wa mikhuva, na nsirhelelo wa xiyimo xa le henhla wa ku hisa, ku chajiwa ku tlula mpimo, na ku humesa ku tlula mpimo, BMS yi kuma swikombiso swo sungula swa ku onhaka ka betri yi nga si khumba matirhelo ya nkoka.


Yi endleriwe ku fambisana ka tikhemikhali to tala, yi seketela tibetiri ta VRLA (Valve-Regulated Lead Acid), Flooded lead-acid, Nickel-Cadmium (Ni-Cd), na Lithium-ion. Yi hlanganisa hi ndlela yo pfumala swiphiqo eka tisenthara ta datha, switichi swa le hansi swa thelekhomu, switichi leswitsongo, swiporo, mimovha ya gezi, vuhlayiselo bya eneji leyi pfuxetiwaka, na tisisiteme ta gezi ra tiindasitiri, leswi endlaka leswaku yi va xitshunxo xa hinkwaswo eka xin’we xa switirhisiwa swa gezi swa manguva lawa.


Hi ku ringanisela ka tisele loku tirhaka, ku rhekhoda ka datha loku nga exikarhi, na mfikelelo wa le kule eka inthanete, DFUN BMS yi antswisa vukorhokeri bya ntirho, yi hunguta ku durha ka vuhlayiseki, na ku tiyisisa nkarhi lowukulu wo tirha—leswi endlaka leswaku yi va nhlawulo lowu tshembekaka eka mabindzu lama lavaka vulawuri bya betri lebyi tshembekaka na vutlhari.

jimeng-2025-12-05-5479-优化电池架的边缘处理使其更加干净,调整透视关系使其更加自然,优化阴影效果使其更加...

Hi DFUN BMS, mabindzu ya nga:

更换BMS后台图片

Sivela ku tsandzeka ka betri loku fihliweke na makhombo ya ku baleka hi ku hisa

Ku antswisa ku tshembheka ka netiweke ya UPS na thelekhomu, ku hunguta nkarhi wo yima

Ku engetela vutomi bya betri na ku hunguta ku cinca & ku hlayisa (TCO) .

Hlanganisa hi ndlela yo pfumala swiphiqo na SCADA na tipulatifomo ta otomatiki ya matimba

Swiphiqo leswi Tolovelekeke swa Betiri eka Tisisiteme ta UPS

Ku Onhiwa ka Matirhelo

Ku Onhiwa ka Matirhelo

Ku lahlekeriwa hi vuswikoti: vuswikoti bya xiviri bya le hansi ku tlula lebyi ringanyetiweke

Ku tlakuka ka ku tiya ka le ndzeni: ku hunguteka ka vuswikoti byo humesa hikwalaho ka ku dyuhala/sulfation

Ku nga ringani ka xibalo xa float: ti voltage leti nga fambelaniki ti hunguta vutomi hinkwabyo

Ku tika ku kambela SOC/SOH hi ku kongoma

Swihoxo swa Gezi

Swihoxo swa Gezi

Overcharge/discharge: swivanga ku lahlekeriwa hi mati, ku onhaka ka plate, kumbe ku baleka hi mahiselo

Swirhendzevutani swo koma kumbe ku vupfa: leswi yisaka eka ku pfala ka UPS kumbe ndzilo

Ku tiya ka le henhla ka ku khumbana: titheminali leti ntshunxekeke/leti rhurhumeleke ti vanga ku hisa na ku lahlekeriwa hi eneji

Ku tsandzeka ka sele yin’we: koka ehansi ntambhu hinkwayo ya betri

Makhombo ya Ntivo-mbango & Vuhlayiseki

Ku hisa lokukulu kumbe ku kufumela loku nga ringaniki: swi hatlisisa ku onhaka naswona swi vanga ku nga ringani.

Ku hlengeletiwa ka gasi ya hayidirojeni: swi tisa khombo ro buluka handle ko vekiwa tihlo hi ndlela leyi faneleke na ku nghenisiwa ka moya.

Ku vupfa ka electrolyte: swi yisa eka ku bola, makhombo ya vuhlayiseki, na swiphiqo swa mbango.

Khombo ra ndzilo ku suka eka ku cinca ka tikhetane leti balekaka hi ku hisa.

Timhaka ta Vuhlayiseki & Vufambisi

Ku kamberiwa hi mavoko a ku tirhi naswona ku tala ku endla swihoxo

Ku vekiwa tihlo ka ntumbuluko ka UPS ku tala ku pimiwile eka xiyimo xa tintambhu ntsena

Swi tika ku kombisa tisele leti hlulekaka hi ku hatlisa

Ku pfumaleka ka nhlayiso wa vuprofeta na vulawuri bya xirhendzevutani xa vutomi

Ntiyiso wa Bangi ya Betiri na 'Vuyelo bya Tisele byo tsana'.

Vuyelo Bya Tisele Lebyi Nga Ni Matimba Swinene

Timhaka ta xiyimo xa tisele ti vanga ku nga ringani ka voltage na ku tsandzeka ka cascading.

Ku tirha ka ntambhu ya betri swi titshege hi sele leyi tsaneke swinene.

Tisele ti nga ri tingani leti tsandzekaka ti nga hunguta swinene nkarhi wa vuhlayiselo ni nkarhi wa vutomi.

Timhaka ta ku nga ringaniseli

Voltage & capacity imbalance: yi kurisiwa endzhaku ka ku chaja ka float ka nkarhi wo leha

Ku nga ringani ka mahiselo: ku hangalasiwa ka kuhisa loku nga ringaniki swi hatlisisa ku dyuhala

Ku nga ringani ka charge/discharge: ku hangalasiwa ka current loku nga ringaniki ku onha ku ringanana

Switandzhaku

Ku hungutiwa nkarhi wa vuhlayiselo bya UPS, ku engetela khombo eka ndzhwalo wa nkoka

Mpimo wa le henhla wa ku cinca na ku tlakuka ka ntsengo wa O&M

Ku engeteleka ka makhombo ya ku humesiwa ngopfu na ku baleka hi ku hisa

企业微信截图_ 17633679854 322. Xihlamusela-marito xa Xitsonga

DFUN BMS vs Vulawuri bya Betiri ya Ndhavuko

DFUN BMS yi nyika vulawuri bya xirhendzevutani xa vutomi lebyi heleleke eka tibetiri hinkwato ta VRLA, Ni-Cd, na Flooded—vuswikoti lebyi tlulaka ku kamberiwa hi voko kumbe UPS BMS ya ndhavuko.

NchumuDFUN BMS ya XitsongaKu Hlayisa VanhuBMS ya UPS
Ku vekiwa tihlo ka SOC ya ntambhuInaXitshuketa/xi nga tirhi kahleNkarhi wa xiviri
Ku vekiwa tihlo ka SOC ya tiseleInaXitshuketa/xi nga tirhi kahleE-e
Ku vekiwa tihlo ka SOH ya tiseleInaXitshuketa/xi nga tirhi kahleE-e
Tialamu & tirhekhodoNkarhi wa xiviri, lowu heleleke, lowu landzelerisiwakaSwi hambanile, a swi tshembekiLimited
Swiviko swa vuhlayisekiSwi endliwa hi ku tisungulelaYi kumeka kambe yi nga tirhi kahleA swi seketeriwi
Ku kombisiwa ka sele ya swihoxoInaE-eE-e
Ku ringanisela ka betriInaE-eE-e
Switsundzuxo swa ku cincaInaE-eE-e
Ku vekiwa tihlo ka tisele ta Ni-Cd 1:1InaE-eE-e
Ku langutisisa electrolyte ya betri leyi khukhuriweke & ku vupfaInaE-eE-e

Ha Yini U Hlawula DFUN BMS?

Xifaniso xa ChatGPT 2025年12月4日 18_55_07

Ku hlanganisiwa loku heleleke:

Yi seketela tibetiri ta VRLA, Ni-Cd, na Flooded eka xiyimo xa tintambhu na tisele


Smart & Ku vhumbha:

Tialgorithm leti tirhisaka AI ti kuma makhombo ka ha ri emahlweni


Ku Landzelela Vuhlayiseki: .

Swipimelo swa IP65 swo sivela mati na UL94 swa ku sivela ndzilo eka tiindasitiri leti nga na khombo

Ku Langutisisa loku Engeteriweke: .

Yi hlanganisa switwi swa mahiselo ya mbango & ku kufumela, switivi swa gasi ya hayidirojeni, swivoni swa swihoxo swa misava, na switwi swa ku vupfa ka DC—leswi funengetaka mbango, gasi, vuhlayiseki, na makhombo ya ku vupfa


ROI ya le henhla: .

Ku engetela vutomi bya betri hi 20–30%, leswi hungutaka ntsengo hinkwawo wa vun’wini


Switirhisiwa swa le Xikarhi ka Vumaki:

Thelekhomu, tisenthara ta data, switirhisiwa swa gezi, swiporo, switichi leswitsongo, tipulani ta tikhemikhali, oyili & gasi, vumaki bya nsimbi

c966bf8e84142714437a9641f61f9363
tonglanbeijingtu2

DFUN BMS Swihlawulekisi swa Nkoka

4200+改英文
4200+英文2
4200+英文3
247Ku Langutisisa ka Nkarhi wa Xiviri

24/7 Ku Langutisisa Hi Nkarhi Wa Xiviri

Ku landzelerisa loku heleleke ka voltage, current, temperature, SOC, na SOH
Tialamu ta nkarhi wa xiviri na ku vika loku lunghekeleke ku odita
Al-Powered Vuhlayiseki bya Vuprofeta

Vuhlayiseki bya Vuprofeta lebyi Fambiwaka hi AI

Ku endliwa ka xikombiso xa mikhuva na ku kamberiwa ka index ya rihanyo

Switsundzuxo swo vhumbha swi antswisa swirhendzevutani swo cinca na ku hunguta TCO

Ku Ringanisela ka VutlhariVulawuri bya Vuhlayiseki

Vulawuri bya ku Ringanisa hi Vutlhari

Yi kuma no lulamisa ku nga ringani hi ku tisungulela

Ku engetela vutomi bya betri hi ku tlhantlha 'weakest cell effect'.

Ripple Voltage & Ku Langutisisa ka Current

Ripple Voltage & Ku Langutisisa ka Current

Ku kuma ku nga tolovelekangi ka chajara/rectifier
Ku hunguta ku onhaka loku fihliweke ka gezi
Xitsundzuxo xa le mahlweni & Tialamu ta LED

Xitsundzuxo xa le mahlweni & Tialamu ta LED

Switsundzuxo swa mahiselo yo tlula mpimo, voltage yo tlula mpimo, ku wa ka vuswikoti
Swikombiso swa LED swi antswisa rivilo ra nhlamulo ya le ndzhawini
Ku Kuma Ku Baleka Hi Ku Hisisa

Ku Kuma Ku Baleka Hi Ku Hisisa

Yi landzelela ku cinca ka mahiselo na ku tiya ka le ndzeni
Yi khoma makhombo ya ku baleka ya xiyimo xo sungula, ku endla leswaku ku nghenelela ku koteka
Ku Tiadirese hi Xiothomethi & Ku Tirhisa Hi Ku Hatlisa

Ku Tiadirese hi Xiothomethi & Ku Tirhisa Hi Ku Hatlisa

Ku nghenisiwa ka plug-and-play hi ku tirhisa tiadirese ta otomatiki
Ku hunguta swihoxo na nkarhi wo khomixini
Nsirhelelo wa Giredi ya Tiindasitiri

Nsirhelelo wa Giredi ya Tiindasitiri

 IP65 ku sivela mati + UL94 ku sivela ndzilo ku tirhisiwa hi ndlela leyi nga na khombo
Yi lulamerile eka tipulani ta tikhemikhali, oyili & gasi na tiindasitiri ta nsimbi
Ku Langutisisa Tibetiri leti Taleke Ndhambi

Ku Langutisisa Tibetiri leti Taleke Ndhambi

 Ku vekiwa tihlo ka mpimo wa electrolyte swi tiyisisa ku chaja/ku humesiwa loku hlayisekeke
Ku kumiwa ka ku vupfa swi sivela ku bola ka acid na makhombo ya vuhlayiseki
Kuma Xikambelo xa Mahala xa Betiri

Un’wana wa vanjhiniyara va hina va BMS u ta hlamula ku nga si hela tiawara ta 24.

(Swa hlawuleka. Ntsena eka timhaka ta xihatla ta xithekiniki)

Hi xixima vuhlayiseki bya wena bya xihundla. Rungula ra wena ri ta tirhisiwa ntsena ku hlamula xikombelo xa wena.

Switirhisiwa swa Sisiteme yo Langutisisa Betiri ya DFUN (BMS) .

PBMS2000-Ti-BM ta Xitichi xa Xiseketelo xa Thelefou

Sisiteme yo Langutisisa Betiri ya Thelekhomu

PBMS9000-Ti-BM ta Senthara ya Data

Ku Langutisisa Betiri ya Senthara ya Data


Swi sivela ku tsandzeka loku fihliweke ka xiyimo xa sele

Tialamu to vhumbha ti hunguta makhombo ya ndzilo

Ku tirhisiwa ka eneji loku antswisiweke, ku hunguta ku durha ka ku cinca

Ku hungutiwa ka matimba kambirhi swi tiyisisa leswaku ku nga ri na nkarhi wo yima


Swikombelo: .

Tisenthara ta datha, switirhisiwa swa timali, switirhisiwa swa le mapapa


Swikumiwa leswi Hlamuseriweke:

PBMS9000 + PBAT61

PBMS2000Pro-Matimba

PBMS2000Pro – Matimba & Swiporo swa Tiindasitiri BMS

99.5% wa vukona ehansi ka tindzhawu ta voltage yale henhla, ya ku rhurhumela

40% ku hatlisa ka nhlamulo ya swihoxo na ku hunguta nkarhi wo lunghisa wa xihatla

Yi seketela ku vekiwa tihlo ka tisele ta Ni-Cd 1:1

Yi seketela ku langutisisa electrolyte ya betri leyi khukhuriweke & ku vupfa


Swikombelo: .

Switirhisiwa swa gezi, switimela swa switimela, tisenthara to lawula giridi


Swikumiwa leswi Hlamuseriweke:

PBMS2000Pro + PBAT71

DFPE1000 ya xirhendzevutani

PBMS900OPrOSubstation & Swi na khombo

PBMS9000Pro – Xitichi lexitsongo,oyili & gasi BMS

Swi hunguta makhombo ya ku buluka eka tindhawu ta tikhemikhali ta petroliyamu

IP65 ku sivela mati + UL94 ku sivela ndzilo ku kuma vuhlayiseki lebyikulu

Dizayini leyi nga onhakiki ku endlela ku tshembheka ka nkarhi wo leha

Yi seketela ku vekiwa tihlo ka tisele ta Ni-Cd 1:1


Swikombelo: .

Switichi leswitsongo, tipulani ta tikhemikhali, oyili & gasi, vumaki bya nsimbi


Swikumiwa leswi Hlamuseriweke:

PBMS9000Pro + PBAT81

DFPE1000 ya xirhendzevutani

Senthara ya Swikumiwa .

Nxaxamelo wa PBAT – Timodyuli ta Vulawuri bya Xiyimo xa Tisele (PBAT51 / PBAT61 / PBAT71 / PBAT81) .

MojuluKu veka ndhawuSwihlawulekisi Swa NkokaSwikombelo leswi Hlamuseriweke
PBAT51Xiyimo xo nghenaKu vekiwa tihlo ka voltage, current, temperature, resistance hi SOC/SOH Tisenthara ta data, makamara lamatsongo ya thelekhomu
PBAT61XiyimoKu vekiwa tihlo ka voltage, current, temperature, resistance hi SOC/SOHTikamara ta UPS, switichi swa thelekhomu swa le xikarhi
PBAT71Ku antswisiwa ka tiindasitiriTi parameters leti heleleke + Electrolyte ya betri leyi khukhuriweke & ku kumiwa ka ku vupfaTisisiteme ta gezi, swiporo, switirhisiwa swa tibetiri leswi khukhuriweke
PBAT81Nsirhelelo wa le HenhlaDizayini leyi nga ngheniwiki hi ndzilo + leyi nga ngheniwiki hi mati (UL94 / IP65)Switirhisiwa swa tikhemikhali, oyili & gasi, vumaki bya nsimbi

FAQ

Q1: Ha yini BMS yi laveka eka tisisiteme ta UPS?

A: Tibetiri ta UPS ti tala ku xaniseka hi ku nga ringani, ku lahlekeriwa hi vuswikoti, na makhombo ya ku hisa. BMS yi endla leswaku ku vekiwa tihlo hi mpimo wa sele, ku kumiwa swihoxo ka ha ri ni nkarhi ni ku hlayisiwa hi ndlela leyi vhumbhiweke—leswi tiyisekisaka ku tshembeka ni ku engetela nkarhi wa vutomi.

Q2: Hi tihi tinxaka ta tibetiri leti DFUN BMS yi ti seketelaka?

Q3: Xana DFUN BMS yi hambanile njhani na native UPS BMS?

Q4: Hi tihi ti indasitiri leti tirhisaka DFUN BMS?

Ti-blog leti fambelanaka na tona .

Tshama u ri karhi u tihlanganisa na hina .

Tshama u ri eku hlanganiseni na hina ku kuma swintshuxo swa sweswinyana eka Sisiteme yo Langutisisa Betiri ya DFUN, vutivi bya xithekiniki, na swintshuxo leswi lulamisiweke eka swilaveko swa wena. Hi tshama hi ri laha ku yingisela no pfuneta.

Ntshungu:+86- 15919182362

E-mail: info@dfuntech.com

Xivutiso