Ɔkyerɛwfo: LIA tintim bere: 2025-09-04 mfiase: Beaeɛ
Wɔ battery management systems (BMS) mu no, asiane a wobu ani gu so kɛse ma lead-acid ne NI-CD battery no mu biako ne ripple current ne ripple voltage. Ɛwom sɛ mpɛn pii no wontumi nhu de, nanso saa anyinam ahoɔden basabasayɛ yi yɛ adwuma te sɛ awudifo a wɔyɛ komm, na ɛma batere no nkwa nna so tew na ɛde ahotoso a ɛwɔ tumi a ɛho hia a wɔde gyina akyi wɔ data mmeae, substations, ne telecom mmeae ahorow no to asiane mu.
Ɛsɛ sɛ battery bi charging ne discharging nhyehyɛe a eye no yɛ DC ahoɔden a ɛyɛ mmerɛw. Nanso, esiane frequency a ɛkɔ soro a ɛsakra wɔ charger ne UPS nhyehyɛe mu nti, AC afã horow a wɔmpɛ no pue:
Ripple Current – AC component a wɔde ahyɛ DC current so, a ɛne adesoa ne charge/discharge cycles no sakra.
Ripple voltage – AC nsakraeɛ a wɔde ahyɛ DC ahoɔden so, a wɔsusuu no wɔ peak-to-peak anaa RMS values mu.
Saa asorɔkye yi taa ba wɔ 50Hz – 1kHz kwan no so na ɛwom sɛ wontumi nhu de, nanso ɛwɔ hɔ wɔ charge cycle biara mu.
Wɔ batere sohwɛ nhyehyɛe biara ho no, Ripple a wobebu wɔn ani agu so no yɛ asiane. Bere kɔ so no, Ripple de ɔsɛe a wontumi nsakra no ba:
Accelerated plate corrosion – Ripple current ma nneɛma a ɛyɛ adwuma no hwie gu, na ɛtew ɔsom nkwa so.
Ɔhyew a ɛboro so – Ripple ma ahoɔden a ɛko tia ne ɔhyew a ɛba no yɛ kɛse; 10°C biara a ɛkɔ soro no ma nnuru a ɛyɛ adwuma no yɛ mmɔho abien, na ɛma electrolyte a ɛyɛ hyew no yɛ ntɛmntɛm.
Tumi a wɔhwere – ripple a wɔde di dwuma bere tenten no ma tumi a etu mpɔn no so tew 30–50%, na ɛma batere akwahosan sohwɛ ne nhyehyɛe mu ahotoso no sɛe.
Nea enti a standard battery BMS nhyehyɛe ahorow no nnɔɔso bio
Battery BMS ano aduru dodow no ara susuw static parameters te sɛ voltage ne current nkutoo, ripple effects a wobu ani gu so. Eyi te sɛ nea worehwɛ nipadua mu hyew nanso sɛ wubu w’ani gu mogya mmoroso so — akwahosan ho nsɛnkyerɛnne a ɛho hia no yera.
Ɛno nti na ɛsɛ sɛ battery monitoring systems a ɛkɔ anim no de ripple monitoring a wɔatu ho ama ka ho na ama wɔatumi de wɔn ho ato so ankasa.
Sɛ́ wiase nyinaa adwumakuw a ɛde batere sohwɛ nhyehyɛe ma no, DFUN de PBMS9000 series a wɔayɛ ama data mmeae akɛse, substations, ne nnwuma a ɛho hia titiriw ma. Ɛkɔ akyiri sen atetesɛm mu nhwehwɛmu a ɛkɔ akyiri a ripple detection a ɛkɔ akyiri:
1. Nsusuwii a ɛyɛ pɛpɛɛpɛ a ɛkorɔn .
Ripple mprempren: 0 ~ 400a sorokɔ, 50Hz – 1kHz, nsusuwii 0.01a .
Ripple ahoɔden: 2 ~ 100VDC peak, resolution 0.01V .
Nneɛma a wɔde hwɛ sɛnea ahoɔden, ahoɔden a ɛko tia, SOC, SOH, ne ɔhyew a ɛwɔ hɔ no yɛ adwuma bom .
2. 24/7 Battery akwahosan ho nhwehwɛmu .
Bere ankasa mu intanɛt so hwɛ a wɔde mfe 5 data sie .
Alarm ahorow a ɛwɔ afã horow pii denam SMS, email, ne mobile app so, mmuae < 10s .
3. Scalable & Robust BMS nhyehyɛe .
Ɛboa batere nhama a ɛkɔ soro kodu 6 (420 – 480 cells) ma VRLA ne NI-CD batere .
Anti-interference design hwɛ ma wotumi de ho to so sɛ wɔbɛyɛ adwuma wɔ UPS mmeae ahorow .
Ɛboa Modbus, SNMP, MQTT, ne IEC61850 protocols ma integration a ɛnyɛ den .
4. Ano aduru a wotumi de ho to so, a wɔagye atom .
Nea ɛne CE, FCC, ROHS, UL adansedi ahorow hyia .
Dual power design hwɛ hu sɛ monitoring no to mu da .
Wɔ nnwuma a ɛwɔ soro a Google Data Centers ne wiase nyinaa nnwuma afoforo a ɛwɔ soro wɔ data center mu no, PBMS9000 Series no ada ne bo adi.
Wɔ amanaman ntam data center mu no, PBMS9000 detected ripple abnormalities asram 6 ansa na ɛreba, na esiw UPS a ɛbɛtwa kɛse no ano.
Battery nkwa nna kɔɔ soro 40%, na ɛtew ɛka a wɔbɔ wɔ nneɛma a wɔde si ananmu no so kɛse.
Battery yɛ ahobammɔ a etwa to wɔ batere sohwɛ nhyehyɛe biara mu, na Ripple yɛ ahunahuna a ahintaw nanso ɛyɛ aniberesɛm. DFUN PBMS9000 Series no ma awo ntoatoaso a edi hɔ no batere sohwɛ nhyehyɛe tumi, de bere ankasa mu ripple detection ne battery akwahosan ho nhwehwɛmu a ɛkɔ anim ma.
DFUN PBMS9000 — BMS ano aduru a ɛyɛ nyansa, ahobammɔ wom, na wotumi de ho to so ma lead-acid ne NI-CD batere wɔ tumi nhyehyɛe a ɛho hia asɛmpatrɛw mu.
Di Dfun ho nkɔmmɔ nnɛ na hu sɛnea yɛn battery BMS ano aduru a ɛkɔ anim no betumi abɔ wo ahoɔden nhyehyɛe ho ban.