In » CHANCHINTHAR » Industry chanchin thar » Hlutna Article » Ripple Current & Ripple Voltage — Battery-te thattu thup, leh DFUN PBMS9000-in i Power System a humhim dan

Ripple Current & Ripple Voltage — Battery-te thattu thup, leh DFUN PBMS9000-in i Power System a humhim dan

Zawhna zawt rawh

facebook ah in share theih a ni
twitter hmanga share theih a ni
line insem theihna button a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

Battery management system (BMS) lamah chuan lead-acid leh Ni-Cd battery tana hlauhawmna ngaihthah ber pakhat chu ripple current leh ripple voltage a ni. Hmuh theih loh fo mah se, heng electrical disturbances te hian silent killers angin hna an thawk a, battery dam chhung a ti tlem a, data center, substation leh telecom site-a backup power system pawimawh tak takte rintlakna a tichhe bawk.

 

Ripple Current leh Ripple Voltage te hi eng nge ni?

Battery charging leh discharging process tha ber chu DC power mumal tak a ni tur a ni. Mahse, charger leh UPS system-a high-frequency switching avang hian AC component duh loh tak tak a lo lang thin:

 

Ripple Current ​​AC component chu DC current chungah dahin, load leh charge/discharge cycle a zirin a inthlak danglam thin.

 

Ripple Voltage  – DC voltage chunga AC inthlak danglamna, peak-to-peak emaw RMS value-a teh a ni.

 

Heng ripple te hi 50Hz 1kHz range ah a awm tlangpui a, hmuh theih loh mahse charging cycle tin ah a awm thin.


 

whats pipple tih hi a ni

 

Engvangin Nge Ripple hian Battery Hriselna A Tichhe?

Battery monitoring system eng pawh tan chuan ripple ngaihthah hi a hlauhawm hle. Hun kal zelah ripple hian chhiatna a thlen leh thei lo a ni:

 

Accelerated Plate Corrosion  – Ripple current hian active materials a ti bo a, service life a ti tlem a ni.

 

Excessive Heat  – Ripple hian resistance leh heat generation a tipung a; 10°C a san apiangin chemical reaction a let hnih a tipung a, electrolyte evaporation a ti chak hle.

 

Capacity Loss  – Hun rei tak ripple exposure hian effective capacity 30–50% in a tihtlem a, battery health monitoring leh system rintlakna a tichhe a ni.


Pipple nghawng- .

 

Engvangin nge Standard Battery BMS Systems te hi a tawk lo?

Battery BMS solution tam zawk hian voltage leh current ang chi static parameter chauh an teh a, ripple effects te chu ngaihthah a ni. Hei hi taksa lum leh vawt enfiah mahse thisen sang inthlak danglamna ngaihthah ang mai a ni — critical health signals te chu a miss a ni.

 

Chuvangin .battery monitoring system hmasawn tak takah chuan rintlak tak tak a nih theih nan dedicated ripple monitoring a tel a ngai a ni


Pipple nghawng a nei

 

DFUN PBMS9000: Critical Power atan Ripple Monitoring hmasawn tak a awm

Khawvel pum huapa battery management system pe chhuaktu a nih angin DFUN hian PBMS9000 Series a pe a, hei hi data center lian tak tak, substation leh infrastructure pawimawh tak takte tan bik a siam a ni. Ripple detection hmasawn tak hmangin traditional monitoring aiin a kal zawk a ni:

 

1. Hriatthiamna sang tak hmanga tehna

 

Ripple Current: 0~400A peak, 50Hz 1kHz, resolution 0.01A a ni

 

Ripple Voltage: 2~100VDC a sang ber, resolution 0.01V a ni

 

Voltage, resistance, SOC, SOH, leh temperature te enfiahna inzawmkhawm

 

2. 24/7 Battery hriselna enfiah

 

Kum 5 chhung data dahkhawmna nen real-time online monitoring neih theih a ni

 

SMS, email, leh mobile app hmanga multi-level alarm, chhanna < 10s

 

3. BMS System Scalable & Robust tak a ni

 

thleng a support thei– 480 cells) VRLA leh Ni-Cd battery tan battery string 6 (420

 

Anti-interference design hian UPS environment-ah rintlak taka hnathawh theihna a siam a ni

 

Seamless integration atan Modbus, SNMP, MQTT, leh IEC61850 protocol te a support bawk

 

4. Solution rintlak, Certified a ni

 

CE, FCC, RoHS, UL certification te zawm tur a ni

 

Dual power design hian monitoring a khar ngai lo tih a tichiang a ni

 

PBM9000 a ni

 

Project tak takah hlutna finfiah a ni

Google data center leh khawvel puma data center company lian panga dangte nena top project-ah PBMS9000 series hian a hlutna a tichiang hle.

 

International data center-ah PBMS9000 hian thla 6 hmain ripple abnormalities a hmuchhuak a, hei hian UPS outage lian tham a veng thei a ni.

 

Battery dam chhung hi 40% zetin a titawp a, hei hian thlak man pawh nasa takin a tihtlem phah a ni.


project case chungchang a ni

 

Tawpna

Battery management system eng pawhah hian battery line of defense hnuhnung ber a ni a, ripple hi hlauhawm thup mahse hlauhawm tak a ni. DFUN PBMS9000 Series hian next-generation battery monitoring system theihna a pe a, real-time ripple detection leh advanced battery health monitoring a pe thei a ni.

 

DFUN PBMS9000 mission-critical power system-a lead-acid leh Ni-Cd battery hmanna tur BMS solution fing zawk, him zawk leh rintlak zawk.

 

Kan battery BMS solution hmasawn tak takte hian i energy infrastructure a humhim theih dan tur hriat duh chuan vawiin hian DFUN hi biak rawh.


Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah zawhfiah theih a ni

A thuneihna chu 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni