So »
Fɛnɲɛnɛmafagalanw »
DFUN BMS ka baarakɛminɛnw ka ɲɛsin kunnafonidilanw ma
DFUN BMS Solutions ka ɲɛsin kunnafonidilanw ma
Tuma caman na, kunnafonidilanw jɔli waati bɛ bɔ batiri barikama kelen na. UPS kɔlɔsili laadalata bɛ juruw wulicogo dɔrɔn de lajɛ, ka seli kelen-kelen bɛɛ tiɲɛni to dogolen na fo ka se waati tɛmɛnen ma.
DFUN ka batiri kɔlɔsili bɛ to ka ka wulicogo, a kɔnɔna rezisti, ani a funteni lajɛ batiri kelen-kelen bɛɛ i ka UPS sitɛmu kɔnɔ. I bɛ lasɔminiw sɔrɔ joona sanni dɛsɛ ka kɛ, ka selilu tiɲɛnenw dɔrɔn bila u nɔ na, ani ka baara tiɲɛniw ban minnu ma labɛn.
Mun na UPS laadala batiri kɔlɔsili bɛ surunya
No cell‐level visibility String voltage bɛ se ka kɛ i n’a fɔ a bɛ cogo la hali ni seli kelen-kelen bɛɛ bɛ ka dɛsɛ.
Ladonni min bɛ kɛ ni wale ye I bɛ gɛlɛya dɔ dɔn dɔrɔn batiri tiɲɛnen kɔfɛ.
Costly & unsafe manual checks Kalo o kalo tension sumani bɛ waati ta ani ka baarakɛlaw bila DC voltage caman na.
No predictive data Ni kɔnɔna resistance trending tɛ, i tɛ se k’a dɔn batiri jumɛn bɛna tiɲɛ kɔfɛ.
DFUN Solution Ka Donanw Santiri Furakɛli | PBMS9000 + PBAT61 ye
Aw bɛ batiri juru 6 kɔlɔsi fo ka se batiri 480 ma (batiri 480 bɛɛ lajɛlen) ni kunnafonisɛbɛn kelen ye
Dual‐power input walasa ka a yɛrɛ tanga dabila ma kuran tiɲɛni waati
Web server min bɛ don a kɔnɔ ni dashboard yelen ye
Kɔlɔsili minnu bɛ se ka sɛgɛsɛgɛ SMS walima imɛri fɛ
Industrie protocole caman – Modbus‐TCP/RTU, SNMP, IEC61850, ani MQTT (JSON) walasa ka ɲɔgɔn sɔrɔ nɔgɔya la
Uplink sugandilen caman – 1x RS485, 2x Ethernet, ani 1x 4G antenne port
DI port 6 (donna nizɛri) ani DO port 6 (mankan/yeelen alarma) walasa ka kunnafoni caman sɔrɔ
Diɲɛ lakika bɛ sɔrɔ kunnafonidilanw bilali kɔfɛ kɔsa in na
Tayilandi kunnafonidilan (batiri 6100) ✅ DFUN BMS ye seli 23 sɔrɔ minnu kɔnɔna kɛlɛli bɛ ka bonya kalo 6 kɔnɔ. Baarakɛla y’u bila u nɔ na ni kɔnɔnafili ye, wa a y’a yɛrɛ tanga juru‐ni-dafabaliya ma.
China Data Center (≈10.000 batteries) ✅ Kɔrɔtɔko lasɔminiw ye dɔ bɔ kɔrɔtɔko weleli la ni 60% ye ani ka batiri si hakɛ caya ni kalo 18 ye.
A bɛ baara kɛ cogo min na – Ka bɔ kunnafonidilanw na ka taa walew la
Kɔlɔsili kɛli tuma bɛɛ – Sensɛri minnu bɛ batiri bɛɛ kan, olu bɛ tension, kɔnɔna rezisti, ani funteni (cell‐level) suman.
Trend analysis – BMS controller bɛ kalanw suma ɲɔgɔn na waati kɔnɔ walasa ka tiɲɛni kɛcogo juguw dɔn.
Predictive alert – Ni selilɛri tɛmɛna dancɛw kan, sistɛmu bɛ SMS/email alarma ci tile walima dɔgɔkun caman sanni a ka dɛsɛ.
Waleya min bɛ kɛ ka ɲɛ – Aw ka jɛkulu bɛ batiri(w) tiɲɛnenw dɔrɔn de bila u nɔ na ladonni bolodalen waati la – zeru jɔli waati.
Fɛn minnu bɛ Ladili
PBMS9000 Batiri kɔlɔsilikɛlan
Contrôleur centralisé min bɛ se batiri 480 ma (6 strings), SNMP/Modbus labɛnnen, web server min bɛ a kɔnɔ.
Yala DFUN BMS bɛ baara kɛ ni UPS taamasiyɛn dɔ ye wa?
Awɔ. An ka sistɛmu bɛ batiriw kɔlɔsi selilɛri hakɛ la, a yɛrɛma ka bɔ UPS taamasiyɛn na. A bɛ ɲɔgɔn Jɛ ni i ka kɔlɔsili kɔrɔ ye Modbus, SNMP, walima RESTful API fɛ.
Ne ka kan ka batiriw falen siɲɛ joli data center kɔnɔ?
Laadalata sariya ye san 3‐5 ye. Ni DFUN BMS ye, i bɛ seliluw dɔrɔn de bila u nɔ na minnu bɛ kɔnɔnajɛya caman jira walima seko bɔnɛnen – tuma caman na, o bɛ batiri si hakɛ caya ni san 2+ ye.
Yala yɔrɔjan kɔlɔsili lakananen don wa?
Awɔ. DFUN BMS bɛ kumaɲɔgɔnya sirilenw dɛmɛ, jɔyɔrɔko siratigɛ la, ani ka baarakɛyɔrɔw bila senkan minnu bɛ se ka kɛ.
Aw kana batiri tiɲɛni nata makɔnɔ walasa ka aw ka batiri barikantanya dɔn.
Ni DFUN ka BMS selilɛri ye, i bɛ yecogo sɔrɔ 24/7 batiri bɛɛ kɔnɔ i ka kunnafonidilan kɔnɔ – walasa i ka se ka dɛsɛw falen i ka sariyaw kan, i tɛ se ka fɛn wɛrɛw bila u nɔ na sɔgɔma 3 waati.