Aƒeme » Egbɔkpɔnuwo » DFUN BMS Egbɔkpɔnuwo na Nyatakakadzraɖoƒe

DFUN BMS Egbɔkpɔnuwo na Nyatakakadzraɖoƒe

Zi geɖe la, wokpɔa nyatakakadzraɖoƒe ƒe dɔmawɔmawɔ tso batri ƒe lãmenugbagbevi ɖeka si gbɔdzɔ gbɔ. UPS ƒe ŋkuléle ɖe nu ŋu si wozãna tsã la léa ŋku ɖe ka ƒe elektrikŋusẽ ŋu ko, si gblẽa lãmenugbagbevi ɖekaɖekawo ƒe gbegblẽ ɖi vaseɖe esime wòtsi megbe akpa.

DFUN’s cell‐level battery monitoring léa ŋku ɖe ƒe elektrikŋusẽ, ememe tsitretsitsi, kple dzoxɔxɔ ŋu ɣesiaɣi . batri ɖesiaɖe si le wò UPS system me Èxɔa nuxlɔ̃ame kaba hafi do kpo nu, ɖɔlia lãmenugbagbevi siwo gblẽ ko, eye nèɖea nutsotso siwo mèle mɔ kpɔm na o ɖa.

Nusita UPS Batri Dzi Kpɔkpɔ Dekɔnu Me Dzudzɔ Kpuie

No cell‐level visibility
String voltage ateŋu adze abe ɖe wòle dzɔdzɔme nu ne cell ɖekaɖekawo le kpo dom nu gɔ̃ hã.
Reactive maintenance
Ne batri la do kpo dɔwɔwɔ le nutsotso aɖe me ko hafi nèva nya nu tso kuxi aɖe ŋu.
Costly & unsafe manual checks
Ɣleti sia ɣleti ƒe voltage dzidzedze xɔa ɣeyiɣi eye wònaa dɔwɔlawo doa go DC voltage gãwo.
No predictive data
Ne ememe tsitretsitsi ƒe nɔnɔme le edzi yim la, màte ŋu anya batri si ado kpo dɔwɔwɔ emegbe o.

DFUN Egbɔkpɔnu Na Data Center Egbɔkpɔnu | PBMS9000 + PBAT61 ƒe ƒuƒoƒo

  • Lé ŋku ɖe batri ƒe ka siwo ade 6 (batri 480 katã) ŋu kple mɔ̃ ɖeka
  • Dual‐power input be woaƒo asa na nutsitsi le elektrikŋusẽ ƒe gbegblẽɣi
  • Wotu web server si me nukpɔkpɔ ƒe dashboard le
  • Dzidzedze blibo le ka ɖesiaɖe me: elektrikŋusẽ, elektrikŋusẽ, mɔxexeɖenu, dzoxɔxɔ, SOC, SOH, tsilénu ƒe tsitretsitsi, kple bubuwo
  • Nuxlɔ̃ame siwo te ŋu trɔna to SMS alo email dzi
  • Dɔwɔƒewo ƒe ɖoɖowɔɖi geɖewo – Modbus‐TCP/RTU, SNMP, IEC61850, kple MQTT (JSON) hena ƒoƒo ɖekae bɔbɔe
  • Tiatia geɖewo uplink – 1x RS485, 2x Ethernet, kple 1x 4G antenna ʋɔtru
  • 6 DI ʋɔtruwo (digital inputs) kple 6 DO ʋɔtruwo (gbeɖiɖi/kekeli ƒe ɣlidodo) na kekeɖenudɔwɔwɔ

Xexeame ŋutɔŋutɔ ƒe emetsonuwo tso nyatakakadzraɖoƒe siwo wozã nyitsɔ laa me

Nyatakakadzraɖoƒe

Thailand Data Center (batri 6,100)
✅ DFUN BMS de dzesi lãmenugbagbevi 23 siwo ƒe ememe tsitretsitsi le dzidzim ɖe edzi le ɣleti 6 me. Dɔwɔla la ɖɔli wo do ŋgɔ eye wòƒo asa na ka ƒe kpododonu.

Batri

China Data Center (≈10,000 batteries)
✅ Nuxlɔ̃ame siwo wogblɔ ɖi ɖe kaƒoƒo kpata dzi kpɔtɔ 60% eye wòdidi batri ƒe agbenɔƒe le mama dedie nu ɣleti 18.

Alesi Wòwɔa Dɔe – Tso Nyatakakawo Dzi Yi Dɔwɔwɔ Dzi

PBMS9000 na Nyatakakadzraɖoƒe Gãwo ƒe Egbɔkpɔnu.png
  1. Kpɔkpɔ ɖaa – Sensors siwo le batri ɖesiaɖe dzi dzidzea voltage, ememe tsitretsitsi, kple dzoxɔxɔ (cell‐level).
  2. Trend analysis – BMS controller tsɔa nuxexlẽwo sɔna kple wo nɔewo le ɣeyiɣi aɖe megbe be yeade dzesi nusiwo gblẽ ƒe nɔnɔme siwo mesɔ o.
  3. Predictive alert – Ne cell aɖe wu thresholds la, ɖoɖoa ɖoa SMS/email alarm ŋkeke alo kwasiɖa aɖewo do ŋgɔ na kpododonu.
  4. Afɔɖeɖe do ŋgɔ – Wò ƒuƒoƒoa ɖɔlia batri(wo) siwo gblẽ la ko le beléle na ɣeyiɣi si woɖo ɖi me – zero downtime.

Adzɔnu Siwo Wokafu

PBMS9000 Batri Dzi Kpɔkpɔ Dzikpɔla

PBMS9000 Batri Dzi Kpɔkpɔ Dzikpɔla

Centralized controller na batri siwo ade 480 (ka 6), SNMP/Modbus dzra ɖo, web server si wotu ɖe eme.

PBAT61 Lãmenugbagbeviwo ƒe Dzesidenu

PBAT61 Lãmenugbagbeviwo ƒe Dzesidenu

Eléa ŋku ɖe elektrikŋusẽ ƒe ŋusẽ, eƒe tsitretsitsi ememetɔ, kple dzoxɔxɔ si le lãmenugbagbevi ɖesiaɖe me ŋu. Nusiwo wowɔna pɛpɛpɛ si de ŋgɔ.

Nyabiasewo ƒe Nyabiasewo

Ðe DFUN BMS wɔa dɔ kple UPS ƒe adzɔnu aɖea?

Ɛ̃. Míaƒe ɖoɖoa léa ŋku ɖe batriwo ŋu le lãmenugbagbeviwo ƒe ɖoɖo nu, le eɖokui si le UPS ƒe dzesidenu me. Edoa ka kple wò ŋkuléleɖenuŋu si li fifia to Modbus, SNMP, alo RESTful API dzi.

Zi nenie wòle be maɖɔli batriwo le nyatakakadzraɖoƒe?

Se si wowɔna le kɔnu nu enye ƒe 3‐5. Le DFUN BMS me la, lãmenugbagbevi siwo ɖea ememe tsitretsitsi alo ŋutete ƒe bu si dzi ɖe edzi fiana koe nèɖɔlia – zi geɖe la, edidia batri ƒe agbenɔƒe le mama dedie nu ƒe 2+.

Ðe ŋkuléle ɖe nu ŋu tso didiƒe le dediea?

Ɛ̃. DFUN BMS doa alɔ kadodo si wotsɔ nya ɣaɣlawo ŋlɔ, akpa si wowɔna ƒe mɔɖeɖe, kple teƒea ƒe dɔwɔwɔ si woate ŋu awɔ le wo ɖokui si.

Mègalala be batri ƒe nutsotso si kplɔe ɖo nava ke ɖe wò batri ƒe gbɔdzɔgbɔdzɔ ŋu o.

Le DFUN ƒe cell‐level BMS me la, èkpɔa 24/7 le batri ɖesiaɖe si le wò data center me – ale be nàte ŋu aɖɔli kpododonuwo le wò ɖoɖowo nu, ke menye le ŋdi ga 3 me o.

Na Batriki ƒe Dzesidede Femaxee

Míaƒe BMS mɔ̃ɖaŋudɔwɔlawo dometɔ ɖeka aɖo eŋu le gaƒoƒo 24 me.

(Ne èdi. Na mɔ̃ɖaŋunya siwo hiã kpata ko)

Míedea bubu wò nyatakakawo ŋu. Woazã wò nyatakakawo atsɔ aɖo wò biabiaa ŋu ko.

Do Ka Kple Mía

Adzɔnuwo ƒe Ƒomedodo

Kadodo Kabakabawo

Te Ðe Mía Ŋu

 ƒe xexlẽme  info@dfuntech.com
   +86- 15919182362
  +86-756-6123188 ƒe xexlẽdzesiwo

Nutata ƒe Gomenɔamesi © 2023 DFUN (ZHUHAI) CO., LTD. Gomenɔamesiwo katã le esi. Ameŋunyatakakawo Ŋuti Ðoɖo | Nyatakakadzraɖoƒe ƒe Nɔnɔmetata