Wɔtaa hwehwɛ bere a data center no gyae adwuma no fi battery cell biako a ɛyɛ mmerɛw so. Amanneɛ kwan so UPS monitoring hwɛ string voltage nko ara, na ɛma ankorankoro cell degradation sie kosi sɛ ɛbɛkyɛ dodo.
DFUN’s cell‐level battery monitoring kɔ so di voltage, emu resistance, ne temperature a ɛwɔ battery biara a ɛwɔ wo UPS system mu no akyi. Wo nsa ka kɔkɔbɔ ntɛm ansa na huammɔdi bi asi, sesa nkwammoaa a asɛe no nkutoo, na woyi nneɛma a ɛtwa mu a wonhwɛ kwan no fi hɔ.
Nea Enti a Amanneɛbɔ UPS Battery Monitoring no Yɛ Tiatiaa
No cell‐level visibility String voltage betumi ayɛ sɛ nea ɛteɛ bere mpo a nkwammoaa ankorankoro redi huammɔ no.
Reactive maintenance Wohu ɔhaw bi ho asɛm bere a battery no adi huammɔ bere a atwa mu nkutoo.
Costly & unsafe manual checks Ɔsram biara voltage susuw gye bere na ɛma adwumayɛfo nya DC voltage a ɛkorɔn.
No predictive data Sɛ woannya internal resistance trending a, wuntumi nhu battery bɛn na ɛbɛdi nkogu akyi.
DFUN Ano aduru Ma Data Center Ano aduru | PBMS9000 + PBAT61 na ɛwɔ hɔ
hwɛ battery nhama a ɛkɔ 6 (batere 480 nyinaa). Fa controller biako
Dual‐power input na wɔakwati sɛ wɔbɛto mu bere a anyinam ahoɔden no asɛe
Wɔasisi wɛb server a ɛwɔ dashboard a wɔde aniwa hu
Nsusuwii a edi mũ wɔ ahama biara mu: ahoɔden, mprempren, impedance, ɔhyew, SOC, SOH, insulation resistance, ne nea ɛkeka ho
Kɔkɔbɔ a ɛyɛ mmerɛw denam SMS anaa email so
Mfiridwuma nhyehyɛe ahorow pii – Modbus‐TCP/RTU, SNMP, IEC61850, ne MQTT (JSON) ma nkabom a ɛnyɛ den
6 DI hyɛn gyinabea (digital inputs) ne 6 DO hyɛn gyinabea (nnyigyei/hann alarm) ma expandable control
Wiase ankasa mu aba a efi data center a wɔde adi dwuma nnansa yi mu
Thailand Data Center (batere 6,100) ✅ DFUN BMS huu nkwammoaa 23 a emu ahoɔden a ɛkɔ soro wɔ asram 6 mu. Odwumayɛni no de wɔn sii ananmu denneennen na ɔkwatii sɛ string‐level huammɔdi.
China Data Center (≈10,000 batteries) ✅ Predictive alerts maa ntɛmpɛ call‐outs so tew 60% na ɛtrɛw battery nkwa nna mu asram 18.
Sɛnea Ɛyɛ Adwuma – Efi Data so Kɔ Adeyɛ so
Kɔ so hwɛ – Sensors a ɛwɔ battery biara so susuw voltage, emu resistance, ne temperature (cell‐level).
Trend analysis – BMS controller no de akenkan toto bere mu de hu sɛnea nneɛma asɛe no a ɛnyɛ ne kwan so.
Predictive alert – Sɛ cell bi boro thresholds a, system no de SMS/email alarm mena nna anaa adapɛn ansa na adi nkogu.
Proactive action – Wo kuw no sesa battery(ies) a ɛdi mfomsoɔ no nko ara wɔ nsiesie a wɔayɛ ho nhyehyɛeɛ mu – zero downtime.
Nneɛma a Wɔkamfo Kyerɛ
PBMS9000 batere sohwɛ sohwɛ .
Centralized controller ma battery a ɛkɔ 480 (6 strings), SNMP/Modbus ayɛ krado, wɔasisi wɛb server.
Aane. Yɛn nhyehyɛe no hwɛ batere so wɔ cell level, a ɛde ne ho fi UPS brand no ho. Ɛnam Modbus, SNMP, anaa RESTful API so na ɛka wo monitoring a ɛwɔ hɔ dedaw no ho.
Mpɛn ahe na ɛsɛ sɛ mesesa batere wɔ data center mu?
Amanne kwan so mmara a wɔde di dwuma ne mfe 3‐5. DFUN BMS, wo sesa nkwammoaa a ɛkyerɛ sɛ emu ahoɔden a ɛkɔ soro anaasɛ tumi a ɛyera nkutoo – mpɛn pii no ɛtrɛw battery nkwa nna mu mfe 2+.
So akyirikyiri a wɔde hwɛ nneɛma so no yɛ nea ahobammɔ wom?
Aane. DFUN BMS boa nkitahodi a wɔabɔ no kokoam, dwumadie a egyina dwumadie so, ne on‐premises deployment a wopɛ.
Mma ntwɛn mma bere a edi hɔ a ɛbɛtɔ na woahu sɛ wo batere no ayɛ mmerɛw.
DFUN cell‐level BMS no, wo nya 24/7 visibility wɔ battery biara a ɛwɔ wo data center mu – enti wobɛtumi asesa huammɔdi wɔ wo nsɛm so, ɛnyɛ 3 AM.