Egbegbe UPS-mɔ̃ akpa gãtɔ naa batri ƒe nɔnɔme ŋuti nyatakaka ƒomevi aɖe. Dɔdzikpɔlawo ate ŋu akpɔ batri ƒe ŋusẽ, charge ƒe alafa memamã, ɣeyiɣi si wobu be wòawɔ dɔ, dzoxɔxɔ, charger ƒe nɔnɔme, alo batri ƒe ɣlidodo si bɔ ɖe UPS ƒe ɖeɖefia alo network ƒe ŋgɔdonya dzi. Nyatakaka sia xɔ asi, gake menye ɣesiaɣie wòɖea batri ɖesiaɖe si le batri ƒe ka gã aɖe si le gota me ƒe nɔnɔme fiana o.

aɖe si le eɖokui si Batrikiwo dzi kpɔkpɔ ƒe ɖoɖo tsɔa ŋkuléleɖenuŋu ƒe ƒuƒoƒo tɔxɛ aɖe kpena ɖe batriawo ŋu. Le alesi woɖoe nu la, ate ŋu adzidze batri ɖekaɖeka ƒe elektrikŋusẽ, dzoxɔxɔ, ememe tsitretsitsi alo mɔxexeɖenu, ka ƒe elektrikŋusẽ, ƒutsotsoe, yame ƒe nɔnɔme, kple ɣeyiɣi didi ƒe nɔnɔmewo. Eyata vovototoa menye ne batri ŋuti nyatakakawo li ko o. Enye nyatakaka mawo ƒe goglome, woƒe vovototodedeameme, woƒe ŋutinya, kple alesi woate ŋu awɔ nu ɖe ​​wo ŋui.

Mɔfiame sia tsɔ UPS ƒe batri dzi kpɔkpɔ si wotu ɖe eme sɔ kple BMS si le eɖokui si eye wòɖe ɣeyiɣi si me UPS ƒe nyatakakawo ate ŋu asu, ɣeyiɣi si me cell- alo block-level visibility hiã, kple alesi ɖoɖo eveawo ateŋu awɔ dɔ ɖekae la me.

Le nyati sia me la, BMS si le eɖokui si fia batri si nɔa teƒe ɖeka si léa ŋku ɖe eŋu. Mele be woatɔtɔe kple ametakpɔnu kple edzikpɔkpɔ BMS si wotsɔ de lithium-ion batri me o.

UPS ƒe batri dzi kpɔkpɔ si wotu ɖe eme ne wotsɔe sɔ kple batri dzi kpɔkpɔ ƒe ɖoɖo si le eɖokui si

Nukae UPS Built-in Battery Monitoring Naa Zi geɖe?

Ele be UPS nakpɔ eƒe batri ƒe ɖoɖoa dzi ale be wòate ŋu axɔ dzo nyuie, abu ɣeyiɣi si woatsɔ adzrae ɖo, ade dzesi vodada gãwo, eye wòakpɔ agbaa ta le elektrikŋusẽ ƒe nudzɔdzɔ aɖe me. Dɔ siwo tututu wowɔna la toa vovo le UPS wɔla, eƒe wɔwɔme, ŋusẽ ƒe dzeside, batri ƒe atikewɔwɔ, kple tiatia siwo woda ɖe eme nu.

UPS ƒe batri ŋuti nyatakaka siwo bɔ ate ŋu anye:

  • Batri alo DC bɔs ƒe elektrikŋusẽ katã
  • Batri ƒe charge kple discharge fifia
  • Batriki ƒe dzoxɔxɔ ƒe alafa memamã alo alesi wobu akɔnta be eƒe dzoxɔxɔ le
  • Ɣeyiɣi si wobu be woawɔ dɔ le agba si li fifia te
  • Charger ƒe nɔnɔme kple dɔwɔwɔ ƒe nɔnɔme
  • Batri alo kabinet ƒe dzoxɔxɔ tso sensor ɖeka alo esi wu nenema gbɔ
  • Batriki si wotsɔ do ka, kadodo si metso o, gbɔdzɔgbɔdzɔ, alo ɖɔliɖɔli ƒe ɣlidodowo
  • Batri dodokpɔ si wowɔ le wo ɖokui si alo esi wodze egɔme kple asi me tsonu

Nyatakaka sia si le ɖoɖoa ƒe ɖoɖo nu kpena ɖe dɔwɔlawo ŋu wosea egɔme nenye be UPS batri dzɔtsoƒea do ka, le dzo dam, le dodom, alo gogo dɔwɔwɔ ƒe seɖoƒe vevi aɖe. Eɖea vi hã na UPS dzikpɔkpɔ le didiƒe to SNMP, network dzikpɔkpɔ kaɖi, DCIM, BMS, alo dɔwɔƒe ƒe mɔnu bubu dzi.

Gake ka ƒe elektrikŋusẽ bliboa si sɔ meɖo kpe edzi be batri ɖesiaɖe si le ka la me le lãmesẽ me o. Batri susɔeawo ate ŋu atsyɔ mɔxenu ɖeka si gbɔdzɔ dzi le tsia ƒe dɔwɔwɔ me, vevietɔ ne elektrikŋusẽ bliboa kple batri ƒe nɔnɔme bliboa koe li.

Nukae Nye Batrikiwo Dzi Kpɔkpɔ ƒe Dɔwɔɖoɖo Si Le Eɖokui Si?

Wode batri ƒe ŋkuléleɖenuŋu ƒe ɖoɖo aɖe si le eɖokui si koŋ be woatsɔ aƒo batri ƒe nɔnɔme ŋuti nyatakakawo nu ƒu ahadzro wo me. Wotsɔa sensorwo doa ka kple lãmenugbagbevi ɖekaɖekawo alo batri ƒe mɔxenuwo, gake mɔ̃ siwo le ka ƒe dzidzeme nu dzidzea fifi kple nɔnɔme bubu siwo woama. Dzɔla alo agbo aɖe dzraa nyatakakaawo ɖo, wɔa ɣlidodowo, eye wòtsɔa nyatakaka tiatia aɖewo yia dɔdzikpɔƒe si le nutoa me alo esi le teƒe ɖeka.

Le batri ƒomevi kple ɖoɖoa ƒe nɔnɔme nu la, BMS si le eɖokui si ate ŋu alé ŋku ɖe:

  • Ame ɖekaɖekawo ƒe lãmenugbagbevi alo block voltage
  • Batriki ƒe nugbɔ ɖekaɖeka alo dzoxɔxɔ si le eme
  • Ememe tsitretsitsi, mɔxexeɖenu, alo ohmic ƒe asixɔxɔ bubuwo
  • Ka ƒe ʋuʋudedi
  • Float, charge, kple discharge fifia
  • Ripple ƒe ʋuʋudedi kple ripple ƒe ʋuʋudedi
  • Yame ƒe dzoxɔxɔ kple fafa
  • Insulation tsitretsitsi, leakage, alo dɔwɔwɔ-koŋ ƒe nɔnɔme bubuwo
  • Ŋutinya me nɔnɔmewo, tsi si woɖe le eme ŋuti nuŋlɔɖiwo, kple alarm ŋutinya

Viɖe vevitɔe nye vodada ƒe teƒeteƒewo ɖoɖo . Le esi teƒe be dɔwɔla la naxɔ batri ƒe ɣlidodo si bɔ ko la, ate ŋu ade dzesi teƒe si wògblẽ nu le, UPS, ka, kple batri ƒe nɔƒe eye wòalé ŋku ɖe alesi eƒe dzidzenuwo trɔ le ɣeyiɣi aɖe megbe ŋu.

UPS Built-in Monitoring vs Independent BMS: Vovototo Veviwo

1. Dzidzedze ƒe Dzidzenu

Zi geɖe la, ŋkuléle ɖe UPS si wotu ɖe eme ŋu nɔa te ɖe batri ƒe ɖoɖo bliboa dzi elabena ehiã be UPS nakpɔ charge, discharge, runtime, kple protection gbɔ. Wotrɔ asi le BMS si le eɖokui si ŋu be wòatsɔ cell- alo block-level visibility akpe ɖe eŋu kpakple ka dzidzedze tsitotsito.

Esia nye vovototodedeameme si bɔ, ke menye xexeame katã ƒe se o. UPS-mɔ̃ aɖewo siwo wowɔna le mɔ vovovowo nu, batri ƒe kabinet siwo me nunya le, kple lithium-ion-mɔ̃wo ate ŋu alé ŋku ɖe module alo lãmenugbagbevi ɖekaɖekawo ŋu. Eyata ele be dɔa ƒe ƒuƒoƒoa naɖo kpe nyatakaka-teƒe ƒe xexlẽdzesi ŋutɔŋutɔ dzi tsɔ wu be wòatsɔe be vovototo si li tso nya siwo nye 'batri dzi kpɔkpɔ si wotu ɖe eme.' me.

2. Ŋutete si le ame si be wòake ɖe batri si gbɔdzɔ ŋu

UPS ate ŋu agblɔ batri si gbɔdzɔ, eƒe dɔwɔwɔ ƒe ɣeyiɣi si dzi ɖe kpɔtɔ, alo ɖokuidodokpɔ si do kpo nu evɔ yemade dzesi batri si koŋ gbɔ wòtso o. BMS si le eɖokui si le lãmenugbagbeviwo ƒe ɖoƒe ate ŋu atsɔ elektrikŋusẽ, dzoxɔxɔ, kple tsitretsitsi ƒe nɔnɔme ɖekaɖekawo asɔ kple wo nɔewo eye wòafia asi beléle na dɔwɔlawo ɖe batri ƒe nɔƒe tututu si hiã numekuku.

Teƒe si nèle pɛpɛpɛ va xɔa asi wu ne gotagome batriwo kple ka siwo sɔ kple wo nɔewo ƒe xexlẽme le dzidzim ɖe edzi.

3. Ŋutinya me Nyatakakawo Kple Nɔnɔmewo Ŋuti Numekuku

Wotrɔ asi le UPS nudzɔdzɔwo ŋuti nuŋlɔɖiwo ŋu koŋ ƒo xlã UPS ƒe dɔwɔwɔ. Woate ŋu alé nusiwo wotsɔ yi teƒe bubu, batri dodokpɔwo, charger ƒe ɣlidodowo, batri ƒe ɖiɖi ƒe nudzɔdzɔwo, kple dɔwɔwɔ ŋuti nyatakakawo ɖi. Goglome kple ɣeyiɣi si woatsɔ alée ɖe te nɔ te ɖe UPS kple dɔdzikpɔkpɔ ƒe kɔmpiutadziɖoɖoa dzi.

Batri ƒe ŋutinya ŋue wotu ŋkuléleɖenuŋu ƒe mɔnu si le eɖokui si. Ate ŋu alé dzidzenuwo ɖe te na batri ɖesiaɖe, atsɔ fifi ƒe asixɔxɔwo asɔ kple gɔmedzedze siwo woda ɖe eme, aɖe deviation afia le ka ɖeka ma ke me, eye wòato tɔtrɔ siwo va le float, discharge, kple recharge ƒe nɔnɔmewo me.

4. Alarm ƒe Nyatakakawo Tsitotsito

UPS ƒe ɣlidodo si bɔ ɖe afisiafi gblɔna na dɔwɔla la be ehiã be wòalé ŋku ɖe eŋu. Ele be batri ƒe ɣlidodo tɔxɛ aɖe nana teƒe si wògblẽ nu le, ka, batri ƒe xexlẽdzesi, parameter, asixɔxɔ si wodzidze, seɖoƒe si woɖo, ɣeyiɣi, kple ɣeyiɣi didime. Dzidzenu vovovowo, heheɖemegbe, hayahaya ƒe susu, kple tɔtrɔ ƒe agbɔsɔsɔme me dzodzro ate ŋu akpe ɖe ame ŋu be woaɖe fuɖename ƒe ɣlidodowo dzi akpɔtɔ.

5. Ðokuisinɔamesi tso UPS ƒe Nuƒolanɔƒea gbɔ

Kpɔkpɔ si wotu ɖe eme nye UPS ƒe lãwo ƒe agbenɔnɔ ƒe ɖoɖo si wotia ƒe akpa aɖe. Nyatakakawo xɔxɔ, kekeɖenudɔwɔwɔ, kɔmpiutadziɖoɖowo, kple kadodomɔnu siwo woate ŋu azã la nɔ te ɖe mɔ̃ ma dzi.

BMS si le eɖokui si ate ŋu alé ŋku ɖe batri ƒe ɖoɖowo ŋu le UPS ƒe adzɔnu vovovowo me eye ate ŋu ana ƒomedodo ɖeka na dɔwɔnu siwo wotsaka ƒe ƒuƒoƒo. Esia ɖea vi na teƒe siwo wɔa UPS ƒe kpɔɖeŋu geɖe, xɔ geɖe, alo ŋkuléleɖenuŋu ƒe dɔwɔƒe si le titina.

6. Dzadzraɖo ƒe susu

UPS ƒe ŋkuléle ɖe nu ŋu doa alɔ ŋusẽ ƒe ɖoɖo bliboa ƒe dɔwɔwɔ. Kpɔkpɔ le eɖokui si doa alɔ batri ƒe beléle na nɔnɔme si wotu ɖe nɔnɔmea dzi. Ekpena ɖe ƒuƒoƒowo ŋu be woatso nya me le batri siwo hiã be woalé ŋku ɖe wo ŋu, agbugbɔ wo ado kpɔ, woalé ŋku ɖe kadodoa ŋu, alo woabu wo ɖɔliɖɔli ŋu.

7. Ŋutete ƒe Kpeɖodzi

UPS ƒe nɔnɔme ƒe dzesi si wozãna le xexeame katã alo batri ƒe ŋkuléle ɖe eŋu edziedzi meɖoa kpe batri ƒe ka ƒe ampere-gaƒoƒo ƒe ŋutete si li dzi le eɖokui si o. Voltage, temperature, current, kple resistance naa nɔnɔmefianu siwo ŋu viɖe le, esime ŋutete alo runtime dodokpɔ si sɔ ɖoa ​​kpe dɔwɔwɔ dzi le discharge nɔnɔme siwo woɖe fia me.

UPS-mɔ̃ aɖewo wɔa batri dodokpɔ siwo wowɔna le wo ɖokui si, gake ele be woato dodokpɔmɔnu, agba, ɣeyiɣi didi si wòxɔna, kple dɔlélewo didi ƒe vovototo me. Dɔwɔƒe veviwo ate ŋu ahiã kokoko be woalé ŋku ɖe woƒe ŋutete ŋu tso ɣeyiɣi yi ɣeyiɣi le batriwɔƒea, beléle na wo ŋuti ɖoɖo, kple dzidzenu siwo sɔ nu.

UPS ƒe ɖoɖo ƒe batri ŋuti nyatakakawo kple lãmenugbagbevi ƒe ɖoɖo si le wo ɖokui si ƒe ŋkuléleɖenuŋu ŋuti nyatakakawo tsɔtsɔ sɔ kple wo nɔewo

Ɣekaɣie UPS Built-in Monitoring Ate Ŋu Asu?

Kpɔkpɔ si wotu ɖe eme ate ŋu asɔ ne batri ƒe ɖoɖoa le sue, afɔkua mesɔ gbɔ o, eye wotu beléle na batri bliboa ɖe batri blibo ɖɔliɖɔli dzi tsɔ wu batri ɖekaɖekawo.

Kpɔɖeŋu aɖewo ate ŋu anye:

  • UPS-mɔ̃ sue siwo ƒe akpa ɖeka nyea batri siwo le dɔwɔƒewo
  • Dɔwɔwɔ siwo me woɖɔlia batri ƒe module bliboa abe unit ɖeka ene
  • Teƒe siwo woɖɔli ɣeyiɣi kpui aɖe le eye woléa ŋku ɖe teƒea ŋu edziedzi
  • Agba siwo menye nu veviwo o le afisi batri ƒe vodada mekpɔ ŋusẽ boo aɖeke ɖe dɔwɔwɔ dzi o
  • UPS ɖoɖo siwo naa module- alo cell-level dzidzenu, ŋutinya, kple alarm siwo hiã xoxo

Ele be woatu nyametsotsoa ɖe dɔwɔwɔ siwo ŋu woɖo kpee dzi, ke menye batri ƒe axa aɖe ƒe anyinɔnɔ le UPS ƒe nukpɔkpɔa dzi ko o. Bia parameter siwo wodzidzena, afisi sensorawo le, nenye be woate ŋu ade dzesi batri ɖesiaɖe, ɣeyiɣi didi si wodzraa nyatakakawo ɖo, kple nyatakaka siwo woate ŋu akpɔ to kadodomɔnua dzi.

Batriki dzi kpɔkpɔ ƒe ɖoɖo si le eɖokui si va xɔa asi wu ne batri ƒe gbegblẽ ate ŋu atɔ te dɔ vevi aɖe alo ne batri ƒe ɖoɖoa lolo akpa be wòate ŋu akpɔ edzi nyuie to asi me toto kple UPS ƒe ɣlidodowo katã me.

Susu siwo bɔ be woatsɔ ŋkuléleɖenuŋu le wo ɖokui si akpe ɖe eŋu dometɔ aɖewoe nye:

  • UPS-ɖoɖo gã siwo me nuwo le etɔ̃ siwo me gotagome VRLA batri ƒe kawo le
  • Batri ƒe ka geɖe siwo sɔ kple wo nɔewo alo batri ɖekaɖeka alafa geɖe
  • Nyatakakadzraɖoƒewo, kɔdziwo, gadzikpɔƒewo, dɔwɔƒewo, ʋuɖoɖo ƒe ɖoɖowo, kple dɔwɔƒe vevi bubuwo
  • Nudidi si nye be woade dzesi batri si gbɔdzɔ tututu hafi ka blibo aɖe nakpɔ ŋusẽ ɖe edzi
  • Hiahiã na ame ɖekaɖekawo ƒe elektrikŋusẽ, dzoxɔxɔ, kple tsitretsitsi ƒe nɔnɔmewo
  • Batrixɔ siwo me ame aɖeke mele o alo dɔwɔƒe siwo le didiƒe ʋĩ
  • Kpɔkpɔ le teƒe ɖeka le UPS ƒe adzɔnu, xɔ, alo teƒe geɖewo me
  • Ðekawɔwɔ kple DCIM, BMS, EPMS, SCADA, alo network dɔwɔƒe aɖe
  • Dzadzraɖo ƒe ɖoɖo siwo bia be woawɔ nuŋlɔɖi tsitotsito, woalé tsi si dona le eme, kple alarm ŋutinya

Menye ŋkuléle ɖe nu ŋu le eɖokui si menye nusi woatsɔ aɖo ŋkuléleɖenuŋu, kadodoa dzi kpɔkpɔ, charger ƒe kpeɖodzi, yaƒoƒo, alo ŋutete dodokpɔ teƒe o. Eƒe taɖodzinue nye be wòana nukpɔkpɔ nanyo ɖe edzi eye wòana beléle na dɔwɔƒea naɖo taɖodzinu geɖe wu.

Ðe UPS ƒe Kpɔkpɔ kple BMS si le eɖokui si ate ŋu awɔ dɔ ɖekaea?

Ɛ̃. Le ŋusẽ ƒe ɖoɖo vevi geɖe me la, dzɔtsoƒe eveawo kpena ɖe wo nɔewo ŋu.

UPS naa dɔwɔwɔ ƒe nɔnɔme abe:

  • Input, output, bypass, kple agba ƒe nɔnɔme
  • UPS ƒe dɔwɔwɔ ƒe nɔnɔme
  • Charger ƒe nɔnɔme
  • Batriki ƒe dzodzo ƒe nudzɔdzɔ
  • Ɣeyiɣi si wobu be woatsɔ awɔ dɔe
  • UPS kple batri ƒe ɣlidodowo le mɔ gbadza nu

BMS si le eɖokui si naa batri ŋuti nyatakakawo abe:

  • Batriki ɖekaɖeka ƒe dzeside
  • Voltage mama le ka la dzi
  • Dzoxɔxɔ ƒe vovototo le batriwo dome
  • Tsitretsitsi alo mɔxexeɖenu ƒe nɔnɔme
  • String fifia kple ripple nuwɔna
  • Batri-level alarm kple beléle na ŋutinya

Ne wotsɔ ɖoɖo eveawo siaa de DCIM, BMS, EPMS, SCADA, alo dɔdzikpɔƒe bubu me la, dɔwɔlawo ate ŋu atsɔ batri ƒe nɔnɔme si mesɔ o asɔ kple UPS ƒe dɔwɔwɔ ƒe nɔnɔme. Le kpɔɖeŋu me, woate ŋu alé ŋku ɖe elektrikŋusẽ ƒe tɔtrɔ le ʋua ƒe dodo me ŋu kpe ɖe agba, elektrikŋusẽ, dɔwɔwɔ ƒe ɣeyiɣi, kple charger ŋuti nyatakakawo ŋu.

UPS kple batri dzi kpɔkpɔ ƒe ɖoɖo si le eɖokui si si wotsɔ wɔ ɖeka kple DCIM alo dɔwɔƒea dzikpɔkpɔ ƒe mɔnu

Nya Siwo Nàbia Hafi Nàɖo Ŋu ɖe UPS Built-in Monitoring ŋu

  1. Ðe UPS la léa ŋku ɖe ka bliboa, batri ƒe module ɖesiaɖe, alo batri ɖekaɖeka ɖesiaɖe ŋua?
  2. Parameter kawoe wodzidzena tẽ, eye asixɔxɔ kawoe wobuna?
  3. Batri ƒe dzoxɔxɔdzidzenu nenie woda ɖe eme, eye afikae wole?
  4. Ðe ɖoɖoa ate ŋu ade dzesi batri si gbɔdzɔ to ka kple teƒe si wòle dzia?
  5. Ðe wodzraa elektrikŋusẽ kple tsitretsitsi ƒe nɔnɔme ɖekaɖekawo ɖoa?
  6. Batriki ŋuti nyatakaka kawoe li to SNMP, Modbus, alo ɖoɖowɔɖi bubu dzi?
  7. Ɣeyiɣi didi kae woléa dzidzenuwo, ɣlidodowo, kple nusiwo dona le eme ƒe nudzɔdzɔwo ɖe te?
  8. Ðe ɖoɖoa ate ŋu alé ŋku ɖe batri ƒe gotagome kabinetwo kple kekeɖenudɔ siwo woawɔ le etsɔme ŋua?
  9. Ðe wòate ŋu aƒo UPS ƒe adzɔnu alo nyatakakadzraɖoƒe geɖe nu ƒu ɖe mɔ̃ ɖeka dzia?
  10. Ðe batri ƒe dodokpɔa ɖoa kpe ŋutete ŋutɔŋutɔ dzia, alo ɖe batri ƒe dɔwɔwɔ le xexeame katã koea?

Alesi DFUN Doa Alɔ UPS Batri Dzi Kpɔkpɔ Le Ðokuisi

Wotrɔ asi le DFUN batri dzi kpɔkpɔ ƒe kuxiwo gbɔkpɔnu ŋu be woatsɔ batri ƒe dzedzeme atraɖii akpe ɖe UPS kple ŋusẽdɔ veviwo ŋu. Ðoɖo siwo li ate ŋu aƒo batri ƒe sensor ɖekaɖekawo, kadzidzemɔ̃wo, dziɖulawo, agbowo, teƒea ƒe nukpɔkpɔwo, kple dɔdzikpɔmɔ̃ siwo le teƒe ɖeka aƒo ƒui.

Le xɔtunu kple batri ƒe ɖoɖo si wotia nu la, ɖoɖoa ate ŋu alé ŋku ɖe ame ɖekaɖekawo ƒe elektrikŋusẽ, dzoxɔxɔ, tsitretsitsi alo mɔxexeɖenu, ka ƒe elektrikŋusẽ, elektrikŋusẽ, ƒutsotsoe, yame ƒe nɔnɔme, SOC, SOH, kple nɔnɔme bubu siwo hiã ŋu. Ŋutinya me fliwo, ɣlidodo ŋuti nuŋlɔɖiwo, tsi si dona le eme ŋuti nyatakakawo, kple nyatakaka siwo woxɔna le didiƒe kpena ɖe dɔwɔlawo ŋu be woaku nu me le nusiwo mesɔ o siwo le ŋgɔ yim ŋu eye wotsɔa beléle na wo ɖoa nɔƒe gbãtɔ.

Kadodo ƒe tiatia ate ŋu ado alɔ ɖekawɔwɔ kple dɔwɔƒewo ƒe ɖoɖo siwo li fifia. Xɔtuɖaŋu si sɔ nɔ te ɖe batri ƒe atikewɔwɔ, block voltage, ka ƒe agbɔsɔsɔ, batri ƒe xexlẽme, UPS ƒe ɖoɖo, kadodo ƒe ɖoɖo, kple teƒea ƒe nɔnɔme dzi.

DFUN le eɖokui si UPS batri dzikpɔkpɔ ɖoɖo kple cell sensors dziɖula kple ŋkuléle ɖe kɔmpiuta dɔwɔɖoɖo

Nya Siwo Wobia Enuenu

Ðe UPS ƒe batri dzi kpɔkpɔ si wotu ɖe eme la sɔ kple BMS tɔxɛ aɖea?

Menye nenema kokoko o. Wotrɔ asi le UPS ƒe ŋkuléleɖenuŋu koŋ ŋu be wòawɔ dɔ kple UPS ɖoɖoa ahakpɔ eta. Batria dzi kpɔkpɔ ƒe ɖoɖo tɔxɛ aɖe léa fɔ ɖe batri dzidzedze tsitotsito, ame ɖekaɖekawo ƒe vodadawo ƒe teƒeteƒewo, ŋutinya, kple beléle na wo me dzodzro ŋu. UPS alo smart battery system deŋgɔ aɖewo ate ŋu awɔ dɔ mawo tɔgbe, eyata ele be woaɖo kpe nyatakaka teƒe ŋutɔŋutɔwo dzi.

Ðe UPS ate ŋu ade dzesi batri ɖeka si gbɔdzɔ le ka didi aɖe mea?

Nuɖoanyi aɖewo ate ŋu ade dzesi module si gbɔdzɔ, gake UPS-mɔ̃ geɖe naa kaƒoƒo ƒe ɣlidodo alo batri ƒe ɣlidodo le xexeame katã ko. Cell- alo block-level sensors hiã ne dɔa bia be woade dzesi batri ƒe nɔƒe tututu.

Ðe BMS si le eɖokui si kpɔa ŋusẽ ɖe UPS dzia?

Zi geɖe la, mɔ̃ aɖe si léa ŋku ɖe batri ŋu si nɔa teƒe ɖeka ƒoa nyatakakawo nu ƒu eye wònaa ɣlidodowo dona. Ate ŋu aɖɔli nyatakakawo kple UPS alo dɔwɔƒea ƒe nuƒolanɔƒe, gake mekpɔa ŋusẽ ɖe UPS la dzi le eɖokui si o negbe ɖe wowɔ dɔa koŋ na dɔ ma hafi.

Ðe BMS si le eɖokui si ate ŋu azã DCIM alo BMS ƒe mɔnu ma ke si UPS zãna?

Ẽ, ne wodo alɔ kadodomɔnu kple nyatakakadzraɖoƒe siwo hiã la. Woate ŋu atsɔ UPS kple batri dzi kpɔkpɔ ŋuti nyatakakawo ayi DCIM, xɔdzikpɔkpɔ, EPMS, SCADA, alo mɔ̃ bubu si le teƒe ɖeka.

Ðe batri dzi kpɔkpɔ xɔ ɖe UPS batri dodokpɔ teƒea?

Ao, ŋkuléle ɖe nu ŋu atraɖii dea dzesi dzidzenu siwo mesɔ o kple alesi wogblẽa nu le wo ŋu. Ŋutete alo dɔwɔwɔ ƒe dodokpɔ ɖoa ​​kpe alesi batri la wɔa dɔe le dzoxɔxɔ ƒe nɔnɔme siwo woɖe fia me dzi. Zi geɖe la, beléle na xɔa ƒe ɖoɖo veviwo zãa evea siaa.

Ðe BMS si le eɖokui si nye VRLA batriwo ɖeɖeko tɔa?

Ao, ŋkuléleɖenuŋu ƒe kuxiwo gbɔkpɔnu ate ŋu ado alɔ VRLA, tsiɖɔɖɔ ƒe lead-acid, Ni-Cd, kple batri ƒe ɖoɖo bubu siwo nɔa teƒe ɖeka. Ele be woaɖo kpe ɖekawɔwɔ dzi na atikewɔwɔ ŋutɔŋutɔ, elektrikŋusẽ si woyɔna be voltage, kple parameters siwo hiã.

Kpɔ Alesi Wò UPS Batriwo Dzi Kpɔkpɔ

Nyametsotso nyuitɔ nɔ te ɖe nusi ado tso batri ƒe gbegblẽ me kple alesi woate ŋu akpɔe xoxo tso UPS gbɔ dzi. Ðo wò UPS ƒe kpɔɖeŋu, batri ƒe atikewɔwɔ, batri ƒe elektrikŋusẽ, batri kple ka ƒe xexlẽme, kadodomɔnu si li xoxo, parameter siwo hiã, kple dzikpɔkpɔ ƒe mɔnu ɖe ​​DFUN. Míaƒe mɔ̃ɖaŋudɔwɔlawo ƒe ƒuƒoƒoa ate ŋu akpe ɖe ŋuwò nànya ne ŋkuléle ɖe lãmenugbagbeviwo ƒe ɖoɖo nu bubuwo sɔ na wò dɔbiagbalẽvia.

Na Batriki ƒe Dzesidede Femaxee

Míaƒe BMS mɔ̃ɖaŋudɔwɔlawo dometɔ ɖeka aɖo eŋu le gaƒoƒo 24 me.

(Ne èdi. Na mɔ̃ɖaŋunya siwo hiã kpata ko)

Míedea bubu wò nyatakakawo ŋu. Woazã wò nyatakakawo atsɔ aɖo wò biabiaa ŋu ko.

Do Ka Kple Mía

Adzɔnuwo ƒe Ƒomedodo

Kadodo Kabakabawo

Te Ðe Mía Ŋu

   +86- 15919182362 xexlẽdzesi
  +86-756-6123188 dzi

Nutata ƒe Gomenɔamesi © 2023 DFUN (ZHUHAI) CO., LTD. Gomenɔamesiwo katã le esi. Ameŋunyatakakawo Ŋuti Ðoɖo | Nyatakakadzraɖoƒe ƒe Nɔnɔmetata