Nnɛyi UPS nhyehyɛe dodow no ara de batere tebea ho nsɛm bi ma. Ebia wɔn a wɔyɛ adwuma no ahu batere ahoɔden, ɔha biara mu nkyem a wɔde charge, bere a wɔasusuw sɛ wɔde bedi dwuma, ɔhyew, charger tebea, anaa battery alarm a ɛfa nneɛma nyinaa ho wɔ UPS display anaa network interface no so. Saa nsɛm yi som bo, nanso ɛnyɛ bere nyinaa na ɛda tebea a batere biara a ɛwɔ batere ahama kɛse bi a ɛwɔ akyi no wom adi.
a ɛde ne ho de Battery monitoring system monitoring layer a wɔatu ho ama ka ho atwa battery no ho ahyia. Ɛgyina nhyehyɛe no so no, ebetumi asusuw batere ankorankoro ahoɔden, ɔhyew, emu resistance anaa impedance, string current, ripple, tebea horow a atwa yɛn ho ahyia, ne nneɛma a ɛkɔ so bere tenten. Enti nsonsonoe no nyɛ sɛ ebia battery data wɔ hɔ ara kwa. Ɛyɛ saa data no mu dɔ, ne nsusuwii, abakɔsɛm, ne sɛnea wotumi yɛ ho adwuma.
Saa akwankyerɛ yi de UPS built-in battery monitoring vs independent BMS toto ho na ɛkyerɛkyerɛ bere a UPS ho nsɛm no betumi ayɛ nea ɛdɔɔso, bere a cell- anaa block-level visibility ho hia, ne sɛnea nhyehyɛe abien no betumi abom ayɛ adwuma.
Wɔ saa asɛm yi mu no, BMS a ɛde ne ho no kyerɛ nhyehyɛe a ɛhwɛ batere a egyina hɔ so. Ɛnsɛ sɛ wɔde frafra ahobammɔ ne control BMS a wɔde afra lithium-ion battery pack mu.
Ɛsɛ sɛ UPS hwɛ ne battery nhyehyɛe so sɛnea ɛbɛyɛ a ebetumi abɔ charge yiye, abu bere a ɛwɔ hɔ a wɔde bɛkora so, ahu mfomso akɛse, na abɔ adesoa no ho ban bere a ahoɔden bi rekɔ so. Dwumadi pɔtee no gu ahorow sɛnea UPS yɛfo, ne mfonini, tumi a wɔde kyerɛ, batere mu nnuru, ne nea wɔde ahyɛ mu no te.
UPS batere ho nsɛm a wɔtaa de di dwuma no betumi ayɛ:
Saa nsɛm a ɛfa nhyehyɛe no ho yi boa wɔn a wɔyɛ adwuma no ma wɔte ase sɛ ebia UPS batere fibea no abɔ, ɛrebɔ, ɛrebɔ, anaasɛ ɛrebɛn adwumayɛ anohyeto a ɛho hia. Ɛsan nso ho wɔ mfasoɔ ma akyirikyiri UPS hwɛ denam SNMP, ntwamutam sohwɛ kaad, DCIM, BMS, anaa adwumayɛbea foforɔ so.
Nanso, ahama no nyinaa ahoɔden a ɛyɛ daa no nkyerɛ sɛ batere biara a ɛwɔ ahama no mu no wɔ apɔwmuden. Ebia batere a aka no bɛkata block biako a ɛyɛ mmerɛw so bere a float reyɛ adwuma no, titiriw bere a voltage nyinaa ne battery tebea nyinaa nkutoo na ɛwɔ hɔ no.
Wɔde batere a wɔde hwɛ nneɛma so nhyehyɛe a ɛde ne ho ahyɛ mu titiriw sɛnea ɛbɛyɛ a wɔbɛboaboa batere tebea ho nsɛm ano na wɔayɛ mu nhwehwɛmu. Wɔde sensor ahorow no bata nkwammoaa ankorankoro anaa batere block ahorow ho, bere a mfiri a ɛwɔ nhama so susuw mprempren ne nneɛma afoforo a wɔkyɛ. Controller anaa gateway bi sie nsɛm no, ɛyɛ alarms, na ɛde data a wɔapaw no kɔ local anaa centralized management platform so.
Ɛdenam batere no su ne nhyehyɛe no so no, BMS a ɛde ne ho betumi ahwɛ:
Mfaso titiriw a ɛwɔ so ne sɛ mfomso ahorow a ɛwɔ baabiara . Sɛ́ anka nea ɔde di dwuma no nsa bɛka batere alarm a ɛfa biribiara ho nkutoo no, obetumi ahu beae a ɛka no, UPS, ahama, ne batere no gyinabea na wahwɛ sɛnea ne susuw sesae bere kɔɔ so no.
UPS built-in monitoring taa twe adwene si battery nhyehyɛe a edi mũ no so efisɛ ɛsɛ sɛ UPS no di charge, discharge, runtime, ne ahobammɔ ho dwuma. Wɔayɛ BMS a ɛde ne ho sɛ ɛde cell- anaa block-level visibility ne afei nso ahama susuw a ɛkɔ akyiri bɛka ho.
Eyi yɛ nsonsonoe a ɛwɔ hɔ nyinaa, na ɛnyɛ amansan mmara. Modular UPS nhyehyɛe ahorow bi, batere nkuku a nyansa wom, ne lithium-ion nhyehyɛe ahorow betumi ahwɛ module anaa nkwammoaa ankorankoro so. Enti ɛsɛ sɛ adwumakuo no hwɛ sɛ data-point list ankasa no yɛ nokware sen sɛ wɔbɛfa no sɛ resolution a ɛwɔ hɔ no fi nsɛmfua 'built-in battery monitoring.'
UPS betumi abɔ amanneɛ sɛ batere a ɛyɛ mmerɛw, bere a wɔde yɛ adwuma no so atew, anaasɛ n’ankasa sɔhwɛ a entumi nyɛ yiye a enhu batere pɔtee a ɛde ba. BMS a ɛde ne ho a ɛwɔ nkwammoaa mu no betumi de ankorankoro ahoɔden, ɔhyew, ne ahoɔden a ɛko tia nneɛma atoto ho na akyerɛ adwumayɛfo a wosiesie batere no gyinabea pɔtee a ɛhwehwɛ sɛ wɔyɛ nhwehwɛmu.
Pɛpɛɛpɛ localization bɛyɛ nea ɛsom bo kɛse bere a abɔnten batere ne parallel nhama dodow kɔ soro no.
Wɔayɛ UPS event logs titiriw atwa UPS dwumadie ho ahyia. Ebia wɔbɛkyerɛw nneɛma a wɔde kɔ baabi foforo, batere sɔhwɛ, charger alarm, battery a ɛba fam nsɛm, ne runtime ho nsɛm. Bere a emu dɔ ne bere a wɔde bɛkora so no gyina UPS ne management software no so.
Atenae a wɔde hwɛ nneɛma so a ɛde ne ho no gyina batere abakɔsɛm so. Ebetumi akora susudua so ama batere biara, de mprempren gyinapɛn ahorow atoto mfitiasede a wɔde ahyɛ mu ho, akyerɛ deviation wɔ ahama koro no ara mu, na asan ahwɛ nsakrae a aba wɔ float, discharge, ne recharge tebea horow mu.
UPS alarm a ɛwɔ hɔ nyinaa ka kyerɛ nea ɔde di dwuma no sɛ ɛsɛ sɛ wɔde adwene si so. Ɛsɛ sɛ batere alarm a wɔatu ho ama ma beae a ɛka, ahama, batere nɔma, parameter, bo a wɔasusuw, anohyeto a wɔahyehyɛ, bere, ne bere tenten. Multi-level thresholds, delay, recovery logic, ne rate-of-change analysis betumi aboa ma wɔatew nuisance alarms so.
Nhwehwɛmu a wɔde ahyɛ mu no yɛ UPS abɔdeɛ a nkwa wom nhyehyɛeɛ a wɔapaw no fã. Data a wobenya, ntrɛwmu, softwea, ne nkitahodi a wobetumi apaw no gyina saa platform no so.
BMS a ɛde ne ho betumi ahwɛ battery nhyehyɛe ahorow so wɔ UPS ahyɛnsode ahorow mu na ebetumi ama nkitahodi a ɛyɛ biako ama mfiri ahorow a wɔadi afra. Eyi ho wɔ mfaso ma mmeae a wɔde UPS mfonini ahorow pii di dwuma, adan pii, anaa beae a wɔhwɛ nneɛma so a ɛwɔ mfinimfini.
UPS monitoring boa adwumayɛ a ɛfa tumi nhyehyɛe a edi mũ no ho. Independent monitoring boa tebea-gyina battery siesie. Ɛboa akuw ma wosi batere ahorow a ɛsɛ sɛ wɔhwehwɛ mu, wɔsan sɔ hwɛ, wɔhwehwɛ nkitahodi mu, anaasɛ wosusuw ho sɛ wɔbɛsesa.
UPS tebea screen a ɛwɔ hɔ nyinaa anaasɛ battery a wɔhwɛ so daa no mu biara nkyerɛ sɛ battery ahama bi tumi yɛ ampere-hour a ɛwɔ hɔ no ankasa. Voltage, temperature, current, ne resistance ma tebea ho nsɛnkyerɛnne a mfaso wɔ so, bere a tumi anaa runtime sɔhwɛ a ɛfata di adwumayɛ ho adanse wɔ discharge tebea horow a wɔakyerɛkyerɛ mu mu.
UPS nhyehyɛe ahorow bi yɛ batere sɔhwɛ ahorow a wɔde wɔn ankasa yɛ, nanso ɛsɛ sɛ wɔsan hwɛ ɔkwan a wɔfa so sɔ hwɛ, adesoa, bere tenten, ne sɛnea wɔde hwehwɛ yare no mu. Ebia mmeae a ɛho hia no da so ara hia sɛ wɔhwɛ sɛnea batere no tumi yɛ adwuma bere ne bere mu sɛnea nea ɔyɛ batere no, nsiesie ho nhyehyɛe, ne gyinapɛn ahorow a ɛwɔ hɔ kyerɛ no.
Ebia ɛbɛyɛ nea ɛfata sɛ wɔhwɛ batere a wɔde ahyɛ mu no bere a batere nhyehyɛe no sua, asiane no sua, na ɔkwan a wɔfa so siesie no gyina batere a edi mũ a wɔbɛsesa so sen sɛ wɔbɛsesa batere ankorankoro no.
Nhwɛso ahorow bi betumi ayɛ:
Ɛsɛ sɛ gyinaesi no gyina dwumadi ahorow a wɔagye atom so, na ɛnyɛ batere kratafa a ɛwɔ UPS display no so kɛkɛ. Bisa sɛ parameters bɛn na wɔsusu, baabi a sensor ahorow no wɔ, sɛ ebia wobetumi ahu battery biara, bere tenten a wɔde sie data, ne nsɛm bɛn na wobetumi anya denam nkitahodi interface no so.
Batere a wɔde hwɛ nneɛma so nhyehyɛe a ɛde ne ho no bɛyɛ nea ɛsom bo kɛse bere a batere no di huammɔ betumi atwitware adeyɛ bi a ɛho hia mu anaasɛ bere a batere a wɔde ahyɛ mu no sõ dodo sɛ wobetumi adi ho dwuma yiye denam nsaano nhwehwɛmu ne UPS alarm ahorow a wɔde bɔ no nyinaa so.
Nteaseɛ a ɛtaa ba sɛ wɔde ahofadiɛ a wɔde hwɛ nneɛma ka ho bi ne:
Independent monitoring nyɛ ade a wɔde besi nhwehwɛmu, nkitahodi a wosiesie, charger no mu adansedi, mframa a wɔde ma, anaa tumi sɔhwɛ ananmu. N’atirimpɔw ne sɛ ɛbɛma wotumi ahu nneɛma yiye na ama wɔde wɔn ani asi nsiesie so kɛse.
Aane. Wɔ tumi nhyehyɛe ahorow pii a ɛho hia mu no, fibea abien no bom.
UPS no de adwumayɛ ho nsɛm te sɛ:
BMS a ɛde ne ho no de battery-specific nsɛm te sɛ:
Sɛ wɔde nhyehyɛe abien no nyinaa ka DCIM, BMS, EPMS, SCADA, anaa nhyehyɛe foforo a wɔde di dwuma ho a, adwumayɛfo betumi de batere a ɛnyɛ ne kwan so abata UPS adwumayɛ tebea ho. Sɛ nhwɛso no, wobetumi ahwɛ voltage deviation bere a discharge no mu abom ne load, current, runtime, ne charger ho nsɛm.
Wɔayɛ DFUN battery monitoring solutions sɛ ɛde battery visibility a ɛkɔ so bɛka UPS ne ahoɔden dwumadie a ɛho hia ho. Nsiesiei a ɛwɔ hɔ no betumi aka batere sensor ankorankoro, nhama susuw mfiri, controllers, gateways, mpɔtam hɔ displays, ne centralized management software abom.
Ɛgyina hardware ne battery nhyehyɛe a wɔapaw so no, nhyehyɛe no betumi ahwɛ ankorankoro ahoɔden, ɔhyew, resistance anaa impedance, string voltage, current, ripple, ambient conditions, SOC, SOH, ne parameters afoforo a wɔhwehwɛ. Abakɔsɛm mu curves, alarm kyerɛwtohɔ, discharge data, ne akyirikyiri amanneɛbɔ boa adwumayɛfo ma wɔhwehwɛ nneɛma a ɛnteɛ a ɛrenya nkɔso mu na wɔde nsiesie di kan.
Nkitahodi akwan horow betumi aboa ma wɔaka abom ne adwumayɛbea nhyehyɛe ahorow a ɛwɔ hɔ dedaw no. Nsiesiei a ɛfata no gyina battery chemistry, block voltage, string dodow, battery dodow, UPS nhyehyɛe, nkitahodi protocol, ne site no atwa yɛn ho ahyia so.
Ɛnyɛ nea ɛho hia ankasa. Wɔayɛ UPS nhwehwɛmu titire sɛ wɔde bɛyɛ adwuma na wɔabɔ UPS nhyehyɛe no ho ban. Batere hwɛ nhyehyɛe a wɔatu ho ama no twe adwene si batere susuw a ɛkɔ akyiri, ankorankoro mfomso beae, abakɔsɛm, ne nsiesie nhwehwɛmu so. Ebia UPS anaa batere a nyansa wom nhyehyɛe ahorow bi a ɛkɔ akyiri no de dwumadi ahorow a ɛte saa ara bɛka ho, enti ɛsɛ sɛ wɔhwɛ sɛ data nsɛntitiriw ankasa no yɛ nokware.
Nhyehyɛe ahorow bi tumi hu module a ɛyɛ mmerɛw, nanso UPS platform pii de string-level anaa general battery alarms nkutoo ma. Cell- anaa block-level sensors ho hia bere a adwuma no hwehwɛ sɛ wohu battery no gyinabea pɔtee no.
Mpɛn pii no, batere a egyina hɔ hwɛ nhyehyɛe bi boaboa nsɛm ano na ɛma alarm ahorow ba. Ebia ɛne UPS anaa facility platform no bɛsesa nsɛm, nanso ɛnhwɛ UPS no so ara kwa gye sɛ wɔayɛ adwuma no pɔtee ama saa dwumadie no.
Yiw, bere a wɔboa nkitahodi nhyehyɛe ne data nsɛntitiriw a wɔhwehwɛ no. Wobetumi de UPS ne battery monitoring data akɔ DCIM, ɔdan sohwɛ, EPMS, SCADA, anaa centralized platform foforo so.
Dabi, sɛnea wɔkɔ so hwɛ nneɛma so no kyerɛ susuw a ɛnyɛ ne kwan so ne sɛnea nneɛma sɛe no. Capacity anaa runtime testing hwɛ sɛnea battery no yɛ adwuma wɔ discharge tebea horow a wɔakyerɛkyerɛ mu mu. Nsiesiei nhyehyɛe ahorow a ɛho hia taa de abien no nyinaa di dwuma.
Dabi, ano aduru a wɔde hwɛ nneɛma so betumi aboa VRLA, flooded lead-acid, Ni-Cd, ne batere nhyehyɛe afoforo a enhinhim. Ɛsɛ sɛ wosi nea ɛne ne ho hyia no so dua ma nnuruyɛ ankasa, ahoɔden a wɔfrɛ no voltage, ne parameters a wɔhwehwɛ.
Gyinaesi a ɛfata gyina nea ebefi batere a asɛe mu aba ne sɛnea wotumi hu ade dedaw fi UPS no so. Send DFUN wo UPS model, battery chemistry, battery voltage, battery ne strings dodow, nkitahodi interface a ɛwɔ hɔ dedaw, parameters a wɔhwehwɛ, ne management platform. Yɛn mfiridwuma kuw no betumi aboa ma wɔahu sɛ ebia nkwammoaa mu nhwehwɛmu foforo fata ma wo application no anaa.