Uninterruptible Power Supply (UPS) tsuas yog txhim khu kev qha raws li lub roj teeb hauv nws. UPS roj teeb tsis ua hauj lwm yog ib qho loj tshaj plaws ua rau lub zog tsis tau npaj tseg hauv cov chaw khaws ntaub ntawv thiab chaw tsim khoom. Kev tshawb fawb los ntawm lub koom haum Ponemon pom tias lub roj teeb tsis ua haujlwm suav txog 65% ntawm cov ntaub ntawv tsis tau npaj tseg - ntau dua li lwm yam hauv paus. Qhov xwm zoo: feem ntau UPS roj teeb tsis ua haujlwm yog tiv thaiv tau.
65%
ntawm cov ntaub ntawv chaw nres tsheb tshwm sim los ntawm UPS roj teeb tsis ua haujlwm
ntawm rated lifespan mus txog hauv lub ntiaj teb tiag tiag vs
80%
ntawm kev tsis ua haujlwm tiv thaiv tau nrog kev saib xyuas kom raug

UPS roj teeb ua haujlwm li cas - Thiab Vim Li Cas Lawv Tsis Ua Haujlwm

Feem ntau UPS cov tshuab siv Valve Regulated Lead-Acid (VRLA) roj teeb, tsim los muab cov hluav taws xob tawg siab rau lub sijhawm luv luv - feem ntau 5 txog 15 feeb - thaum lub sijhawm hluav taws xob tsis zoo. Lithium-ion UPS roj teeb muaj ntau dua, muab kev pabcuam ntev dua ntawm tus nqi siab dua.

Ob hom roj teeb yog cov khoom siv hluav taws xob hluav taws xob uas khaws thiab tso tawm lub zog los ntawm cov tshuaj tiv thaiv, ua rau lawv nkag siab zoo rau qhov kub thiab txias, lub voj voog, qhov tseeb voltage, thiab lub cev ib puag ncig. Thaum ib qho ntawm cov xwm txheej no poob rau sab nraud qhov kev lees paub, lub roj teeb lub neej luv luv - qee zaum ua rau.

Lub 9 Qhov Tseem Ceeb Uas Ua Rau UPS Roj Teeb Tsis Ua Haujlwm

Ua haujlwm kub siab

Kub yog tus yeeb ncuab thib ib ntawm UPS roj teeb lub neej. VRLA roj teeb raug ntsuas ntawm qhov kev ua haujlwm nominal ntawm 25 ° C (77 ° F) . Rau txhua txhua 10 ° C nce siab tshaj qhov pib no, roj teeb kev pab cuam lub neej raug txiav ib nrab - 5-xyoo roj teeb dhau los ua 2.5-xyoo roj teeb ntawm 35 ° C, thiab kav ntev tshaj li 1 xyoos ntawm 45 ° C.

Cov cim ceeb toom: UPS cov ntaub ntawv muaj qhov sov tsis zoo; luv luv runtime; Lub tswb nrov qis ua rau ntau zaus.
Kev Tiv Thaiv: Khaws UPS chav sov tsis tu ncua ntawm 20-25 ° C. Xyuas kom muaj cua txaus txaus. Ntxuav cov cua lim txhua hli. Siv cov thermal imaging scans thaum lub sij hawm tu.

Kev them nyiaj ntau dhau

Kev them nyiaj ntau dhau tshwm sim thaum UPS charger siv lub ntab hluav taws xob siab dua li cov chaw tsim khoom roj teeb qhov tshwj xeeb. Qhov no ua rau muaj roj ntau dhau, ua kom lub cev qhuav dej thiab ua kom kub siab - uas ua rau cov cua sov khiav tawm, qhov cua, lossis hluav taws kub.

Cov cim ceeb toom: roj teeb casing kub kov; tshuaj tsw qab txawv txawv; rooj plaub; roj teeb ua txhaum txawm yog tus tshiab.
Kev Tiv Thaiv: Ib txwm txheeb xyuas qhov teeb tsa hluav taws xob charger raws li lub chaw tsim khoom roj teeb qhov tshwj xeeb.

Undercharge thiab Sulfation

Kev them nyiaj tsis tu ncua qis dua qhov ntsuas hluav taws xob ua rau cov hlau lead sulfate ua rau ntawm cov roj teeb - ib qho mob hu ua sulfation. Thaum lub sij hawm, cov crystals harden thiab ua electrochemically inactive, mus tas li txo lub peev xwm.

Cov cim ceeb toom: Qhov hluav taws xob poob qis hauv qab load; ncua sij hawm recharge; tsis tshua muaj hluav taws xob tswb.
Kev Tiv Thaiv: Xyuas kom muaj qhov hluav taws xob ntab ntab raug teeb tsa kom raug. Rau cov roj teeb uas khaws cia, ua haujlwm them nyiaj txhua txhua 3-6 lub hlis.

Tshaj Tawm Cycling

UPS roj teeb yog cov khoom siv standby, tsis yog cov roj teeb sib sib zog nqus. Txhua lub voj voog tawm-thiab-tso rov qab me ntsis txo qhov peev xwm. Ib puag ncig uas nquag cuam tshuam lub zog ua kom lub zog degradation.

Cov cim ceeb toom: Lub sijhawm ua haujlwm nce zuj zus luv dua lub hlis; Kev kuaj muaj peev xwm qhia tau hais tias kev poob qis.
Kev Tiv Thaiv: Loj UPS roj teeb muaj peev xwm txo qis qhov tob tob. Siv kev tiv thaiv surge ntawm lub tsev.

Hnub nyoog cuam tshuam txog peev xwm poob

Txawm nyob rau hauv cov xwm txheej zoo tag nrho, txhua lub roj teeb muaj lub neej ua haujlwm ntev. VRLA roj teeb feem ntau kav ntev li 3-5 xyoos; lithium-ion roj teeb 8-10 xyoo. Kev poob peev yog feem ntau pom tsis pom ntawm qhov kev kuaj xyuas voltage.

Kev pom tseem ceeb: Tsis txhob cia siab rau kev nyeem ntawv voltage ib leeg. Kev ntsuam xyuas impedance (ib lub hlis twg) thiab qhov ntsuas qhov muaj peev xwm tso tawm tag nrho (ib xyoos ib zaug) qhia qhov degradation zais cia.
Kev Tiv Thaiv: Hloov VRLA roj teeb ua haujlwm txhua 3-5 xyoos, tsis hais qhov xwm txheej tshwm sim.

Thermal Runaway

Thermal runaway yog qhov txaus ntshai tshaj plaws UPS roj teeb tsis ua haujlwm. Nws tshwm sim thaum lub zog hluav taws xob sab hauv siab tshaj lub roj teeb lub peev xwm los dissipate nws - tsim kom muaj lub voj voog ntawm tus kheej uas tuaj yeem ua rau hluav taws kub lossis tawg.

Cov cim xwm txheej ceev: ceev ceev roj teeb kub; muaj zog tshuaj tsw qab; pom o; UPS charger ntawm qhov tso zis siab tas li.
Kev Tiv Thaiv: Siv UPS nrog kev them nyiaj kub-compensated. Saib xyuas roj teeb kub tsis tu ncua. Hloov cov roj teeb o lossis overheating tam sim ntawd.

Terminal Corrosion thiab kev sib txuas tsis zoo

Corrosion (dawb lossis ntsuab residue) nce hluav taws xob tiv thaiv thiab txo cov khoom xa tuaj tam sim no. Kev sib txuas xoob ua kom muaj cua sov hauv qab load thiab tuaj yeem ua rau arcing.

Cov cim ceeb toom: Dawb los yog ntsuab ntsuab seem ntawm cov terminals; voltage poob nyob rau hauv load disproportionate rau roj teeb hnub nyoog.
Kev Tiv Thaiv: Tshawb xyuas thiab ntxuav cov terminals ntawm txhua qhov kev saib xyuas. Siv tshuaj tiv thaiv corrosion. Xyuas lub davhlau ya nyob twg torque raws li specifications.

Hom roj teeb tsis raug lossis hloov tsis tau

Lwm cov roj teeb uas tsis muaj nqi nrog cov nqi them tsis sib xws feem ntau ua tsis tiav, ua rau muaj kev hloov pauv thaum muaj xwm txheej ceev thiab tus nqi siab dua.

Cov cim ceeb toom: Cov roj teeb tshiab qhia txog kev ua yuam kev tsis ntev tom qab kev teeb tsa; them tus cwj pwm txawv txav.
Kev Tiv Thaiv: Ib txwm siv cov roj teeb tshwj xeeb los yog cov khoom sib npaug uas tau lees paub. Nrog DFUN ua ntej hloov cov kev xaiv.

Lub cev puas tsuaj thiab ua haujlwm tsis zoo

Sab hauv phaj puas los ntawm kev cuam tshuam lossis kev vibration thaum khaws cia, xa khoom, lossis kev teeb tsa tuaj yeem ua rau lub xov tooj luv luv uas ntog raws li qhov tsis ua haujlwm thaum thawj zaug tso tawm.

Cov cim ceeb toom: Lub roj teeb tshiab uas tau teeb tsa tsis tau sai; Kev ntsuas muaj peev xwm qhia tau tias kev ua haujlwm tsis zoo tam sim tom qab kev teeb tsa.
Kev Tiv Thaiv: Ua raws li cov chaw tsim khoom tuav cov lus qhia. Siv cov ntim khoom qub rau kev thauj mus los. Ua qhov ntsuas qhov peev xwm hauv paus tom qab txhua qhov kev teeb tsa.

Kev ceeb toom qhia tias koj lub roj teeb UPS ua tsis tiav

Ceeb Toom Kos Npe Zoo Li Cas
Shorter runtime thaum muaj hluav taws xob Tsis muaj peev xwm poob, sulfation, laus
Tsis tshua muaj roj teeb tswb Capacity poob, undercharging
Lub roj teeb lossis UPS lub qhov rooj xav tias kub Overcharge, thermal runaway pheej hmoo
Nruam beeping nrog lub zog tam sim no Roj teeb tsis ua hauj lwm, internal tivthaiv tsis ua hauj lwm
o los yog deformed roj teeb casing Overcharge, kub puas tsuaj - ua tam sim ntawd
Dawb / ntsuab residue ntawm terminals Corrosion
UPS tsis hloov mus rau roj teeb Cov hlwb tuag, qhib Circuit Court, sulfation
Tshuaj tsw qab nyob ze ntawm UPS Electrolyte leakage, thermal tshwm sim

UPS roj teeb Maintenance Schedule

Kev tshawb fawb tsis tu ncua qhia tau hais tias 75-80% ntawm UPS roj teeb tsis ua haujlwm yog tiv thaiv tau nrog cov txheej txheem kev saib xyuas:

  • Txhua hli: Tshawb xyuas cov ntawv teev xwm txheej, tshuaj xyuas qhov muag, txheeb xyuas qhov kub thiab txias, lim lim.
  • Peb lub hlis twg: Kev ntsuam xyuas impedance, cav ntab voltage, tshuaj xyuas cov terminals rau corrosion, txheeb xyuas lub zog.
  • Ib xyoos ib zaug: Tag nrho lub peev xwm tawm mus kuaj, ntsuas qhov ntsuas cua sov, tshuaj xyuas lub hnub nyoog roj teeb thiab kev npaj hloov pauv.
  • Thaum 3-5 xyoos: Hloov VRLA roj teeb ua haujlwm; Kev ntsuas qhov peev xwm hauv paus tom qab hloov pauv; txheeb xyuas qhov chaw charger rau cov roj teeb tshiab.

VRLA vs. Lithium-ion UPS roj teeb

VRLA (Lead-Acid)
  • Lub neej ua haujlwm: 3-5 xyoos
  • Kub kub rhiab heev
  • Tsawg tus nqi ua ntej
  • hnyav dua
  • Kev tu ntau zaus
Factor VRLA (Lead-Acid) Lithium-Ion
Kev pab lub neej 3-5 xyoos 8-10 xyoo
Kub rhiab heev Siab Nruab nrab
Tus nqi ua ntej qis Siab dua
Qhov hnyav Hnyav Sib dua
Kev tu ntau zaus Siab dua qis
Ntev mus tag nrho cov nqi ntawm cov tswv cuab Feem ntau siab dua Feem ntau qis dua

Cov ntsiab cai tseem ceeb tiv thaiv

Tswj ib puag ncig: Khaws kev ua haujlwm kub ntawm 25 ° C thiab tswj kom huv si, tsis muaj kev cuam tshuam cov huab cua.
Txheeb xyuas cov kev them nqi: Sib phim ntab qhov hluav taws xob kom meej rau lub chaw tsim khoom roj teeb qhov tshwj xeeb.
Kev sim tsis tu ncua: Kev ntsuas impedance (lub hlis twg) thiab kev ntsuas qhov muaj peev xwm tawm (ib xyoos ib zaug) qhia qhov kev degradation zais cia.
Hloov ua haujlwm: Tsis txhob tos rau VRLA roj teeb ua tsis tiav dhau los ntawm 3-5 xyoos.
Siv lub roj teeb kom raug: Ib txwm siv cov chaw tsim khoom tshwj xeeb lossis cov ntawv pov thawj tiav-tau hloov pauv.

Tau txais kev ntsuam xyuas roj teeb dawb

Ib tug ntawm peb BMS engineers yuav teb tsis pub dhau 24 teev.

(Yeem xaiv tau. Tsuas yog rau cov teeb meem ceev ceev)

Peb hwm koj tus kheej. Koj cov ntaub ntawv tsuas yog siv los teb rau koj qhov kev thov.

Txuas Nrog Peb

Yam khoom

Txuas ceev

Tiv tauj peb

   +86- 15919182362
Xov tooj:   +86-756-6123188

Copyright © 2023 DFUN (ZHUHAI) CO., LTD. Txhua txoj cai. Txoj Cai Tswjfwm Ntiag Tug | Daim duab qhia chaw