Kan hriat vek angin khawpui pakhatah hian BTS tower za tam tak emaw, sang tam tak emaw a awm thei a, chungte chuan inbiakpawhna hmanrua engemaw zat an kalpui a, khawpui pum huap inbiakpawhna tha leh nghet tak a thlawp a ni. Heng Telecom BTS Tower te hi hmun hrang hrangah then hran a ni. Ṭhenkhat chu tlang chhip-ah sak a ni a, ṭhenkhat chu ram hring tamna hmunah emaw, mipui tamna khawpuiah emaw ram a ni.


Communication device zawng zawng chu a kal tha vek theih nan BTS tower tin hian beisei loh taka shun-down dinhmun hmachhawn turin backup power system an siam ang.


Engtin nge backup power system te hi him leh nghet taka an thawh theih nan, a bik takin BTS tower hi hmun hrang hranga hla tak leh a hranpaa a awm lai hian? Cell site tam tak tana remote battery monitoring system siam hi Telecom industry tan chuan harsatna lian tak a ni fo thin.

Kum 2013 April thlaa din, DFUN (ZHUHAI) CO., LTD. hi ram pum huapa high-tech enterprise a ni a, Battery Monitoring System, Lithium Smart Battery, Energy Storage solution te a ngaih pawimawh ber a ni. DFUN hian domestic market-ah branch 5 a nei a, ram 50 chuangah agent a nei a, khawvel hmun hrang hranga customer-te hnenah hardware & software service pahnih tan total solution an pe a ni. Kan thil siamte hi Industrial leh commercial energy storage system, Data Center, Telecoms, Metro, substation, petrochemical industry, etc. ah te hman a ni nasa hle a, key customer te zingah Eaton, Statron, APC, Delta, Riello, MTN, NTT, Viettel, Turkcell, True IDC, Telkom Indonesia leh a dangte pawh an tel. International company a nih angin DFUN hian professional technical support team a nei a, darkar 24 chhung online service a pe thei a ni.



1.Engvangin nge Telecom tana Monitoring System tha tak hman a tul?


Telecom Operations atan chuan


Labor leh Maintenance Cost tihtlem

Monitoring system hian i battery te chu automatic in a enfiah thei a, battery tin voltage, internal temperature, impedance, SOC te a teh thei a, string current, string voltage, etc. te a teh thei a, MODBUS TCP emaw 4G hmangin system ah data a thawn thei bawk. Battery-a thil awmdan pangngai lo a awm chuan alarm a rawn thawn chhuak ang che. Chuvangin BTS Tower maintenance hian remote atanga site tlawh a ngai lo va, system a data awm chu a check mai a, chutah chuan site tin battery status a hre thei ang.


Telecom Station himna tur ngaihtuah

I hriat angin lead-acid battery hman dik loh chuan kangmei emaw, puak emaw accident a thlen fo thin. Monitoring system hian heng accident te hi a veng thei a, a chhan chu i battery-a thil awm dan pangngai lo, overcharge/discharge emaw over-temperature situation te, leh a dangte a hriat theih avangin. Battery monitoring system-a thil pawimawh ber chu tihsual a awm chuan alarm chu maintenance-ah an thawn chhuak ang a, chutiang chuan an harsatna chu rang taka an chinfel theih nan a ni.


Battery thlak tlem leh Environment humhalh

Heng system te hian cell tinte hriselna data chu intuitive takin an enfiah thei a; maintenance hian data curve hmangin battery hriselna a rel thei a, local the problem battery. Chutiang chuan string battery pum pui thlak ai chuan individual problem battery chauh thlak a ngai a ni. Hei hian enkawlna senso leh boruak bawlhhlawh a tihtlem phah dawn a ni.


Remote atanga Battery Status enfiah leh Problem Battery awmna hmun zawn

Remote monitoring premise pumpui chu khawvel hmun hrang hrang atangin i network i en thei tih hi a ni. System hian MODBUS-TCP emaw 4G emaw hmangin distributed station data chu centralized system-ah data upload turin a enfiah thei a ni. Battery data in setting alarm data a pelh chuan system chuan maintenance hnenah eng station nge eng battery nge harsatna nei tih a hrilh ang.


Maintenance ah Alarm thawn chhuak rawh

Remote monitoring system awm lo se chuan maintenance hian BTS tower battery tin hi vawi khat tal enfiah a ngai a ni. Hei hi hna lian tak leh lu na tak a ni. A chhan chu khawpui chhung hmun hrang hrangah an insem darh a, tum nei lovin tuipuiah needle man ang mai a ni. Battery monitoring system hian SMS alarm emaw email alarm emaw a keng tel a, hei hian maintenance chu a kaihhnawih BTS tower tlawh a, battery harsatna awmna hmun hriat theihna turin a pui a ni.


2.Battery Monitoring System te hi engtin nge a thawh?


Battery monitoring system (BMS) hi a hun takah remote atanga battery hriselna enfiahna system a ni. Battery monitor system hlui ang lo takin DFUN-a battery monitoring system hian battery pakhat zel voltage, internal temperature, impedance, SOC, leh SOH te a enfiah thei a ni. Chuvangin battery bank-ah harsatna a awm chuan engineer chuan rang takin battery-a harsatna awm chu a hrechhuak thei a ni. System install dan pawh a awlsam hle. Battery pakhat zel data hmuh theih nan battery voltage monitoring system-ah chuan battery tinah battery sensor dah a ngai a ni. Tichuan chu battery sensor te chu pakhat hnu pakhatin an inzawm khawm ta a ni. Tichuan engineer chuan auto-searching battery ID address function chu a on thei a, system chuan battery tin chu battery sensor tin nen automatic in a match thei a ni. Chuvangin system hian BTS station tinte data a khawlkhawm ang a, battery tin data inmil chu a check thei ang. Data alarm threshold set hian system chuan maintenance hnenah Email leh SMS hmangin real-time alarm a thawn chhuak ang.


3.Telecom tana DFUN Battery Monitoring System te


Telecommunication battery monitoring solution atan hian DFUN hian BTS station tin tan PBM2000 leh PBAT-Gate a pe a, station hrang hrang engemawzat tan centralized monitoring system atan DFCS4100 a pe bawk.


PBMS2000 a ni

PBMS2000 solution hi 48V power supply system-ah hman a ni ber a, hei hi solution man tlawm tak a ni. Battery string 2 tam ber a monitor thei a, 120pcs lead-acid battery a nei bawk. Ethernet port hmang hian MODBUS-TCP emaw SNMP emaw hmangin system-ah data a upload thei a ni.


PBAT-Gate-ah a awm

PBAT-Gate Solution hian battery string 4 leh a vaiin lead-acid battery 480pcs monitoring a support a ni. Built-in server a neih avangin web-based system te tak te a nei a, chu chuan web page-a battery status zawng zawng a enfiah thei a, engineer-te tan chuan awlsam leh awlsam taka hman theih a ni. 4G wireless communication pawh a support bawk. Chuvangin a tlangpuiin BTS station hlui thenkhat Ethernet port nei lo tan hman a ni.


Tawpna

Distributed BTS station tam tak tan remote battery monitoring hi telecommunication tan chuan hna lian tak a ni. DFUN hian kum 8 chuang zet Telecommunication industry tan battery monitoring system hi dah leh pawm a ni tawh a ni. He solution hi Telecommunication company lian tam zawkah hman a ni tawh a, site bik thenkhat tan chuan customized solution pawh an pe thei bawk. Chuvangin i tih theih ber tih i ngaihtuah laiin i telecom battery te enkawl hna thawk se, i customer te hlim taka awm tir rawh!



Kan Inzawmkhawm