In » CHANCHINTHAR » Industry chanchin thar . » Data Center atana Battery Monitor tha ber ber

Data Center atana Battery Monitor tha ber berte

Zawhna zawt rawh

facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni


Tunlai data-driven khawvelah hian data center hi sumdawnna eng pawh tan chuan thil pawimawh tak a ni. Kum sawm kalta chhung khan data storage leh management mamawhna nasa takin a pung a, hei vang hian data center-te scope, scale leh complexity a tipung a ni. Hetiang dinhmun hnuaiah hian remote monitoring solutions, a bik takin a tha ber berte battery monitor hian  sumdawngte, data center neitute leh service provider-te chu data center enkawlna kawng tinrengah automate-in a ti thei a ni.


Remote battery monitoring hian operational efficiency a ti sang a, cost a ti tlem a, uptime a ti tha bawk. Tin. Chuvangin, engkim chhinchhiah theihna turin battery monitor i mamawh a ni. He thuziak hian tuna data center awm mekte tana battery monitor tha ber berte kan sawi dawn a ni. Chhiar la, thu belhchian dawl zawk zawng rawh.


Data Center atana Battery Monitor tha ber chu eng nge ni?


Kan hriat angin data center-a backup power system-ah hian battery hian hmun pawimawh tak a chang a ni. Chutiang chuan backup battery te a chhiat chuan economic loss chu ngaihtuah phak loh a ni ang. Mahse, data center pakhat hian engtik lai pawhin kilowatt engemaw zat energy a hmang thei a, power a tlakchhiat chuan he load hi battery engemaw zatah sem darh a ni ang. Heng battery te hian an chunga load dah chu an support bakah hian main power source a lo awm leh theih hma loh chuan hun bituk chhung atan load dang an phur thei bawk tur a ni.


Chuti a nih chuan engtin nge big data center-a battery za tam tak emaw, sang tam tak emaw kan enkawl theih ang? Hetah hian battery monitor a rawn lang ta. Battery monitor hi hmanraw hlu tak a ni thei a, chu chuan data center manager-te chu an data center UPS battery hriselna zawng zawng a teh thei a, harsatna a awm chuan a hriattir thei bawk. Mahse, application tin tan monitoring solution dik tak thlan hi a pawimawh hle.


Engtin Nge Battery Monitor tha ber hian Data Center a puih?


Battery monitoring solution sang tak hman a nih chuan operator-te chuan a hnuaia hlawknate hi an hmu thei ang:


1. Security leh Efficiency tihchangtlun nan Active Monitoring neih a ni


Traditional takin engineer-te chuan battery chu pakhat hnu pakhatin kut hmanga test a ngai a, battery data chu analysis atan an ziak chhuak thin. Hun rei tak a daih a, data dik lo a thlen ngei ang. Battery monitor tha ber atanga battery chhiatna hriat hmasak chu active a ni. Reading chu manual-a record a, a hmaa reading nena khaikhin a ngai lo, a bik takin data center atana offline testing system i hman hunah. Engtik lai pawha active monitoring tracking hmangin i data center-a security leh efficiency a ti sang thei a ni.


2. Risk tihziaawmna turin Real-Time Data Monitoring neih a ni


Real-time monitoring hian power outage emaw low voltage alarm emaw avanga hloh tur a pumpelh thei a ni. Battery monitoring system ah alarm value i set thei a, chutah chuan battery voltage, internal temperature leh impedance te chu limit value aia tam a ni. Maintenance person hnenah alarm a thawn chhuak ang a, a tul chuan hma a la nghal ang.


3. Quick Inspection leh Maintenance atan awlsam taka hman theih


Battery monitor tha ber berte puihnain battery cell sensor zawng zawng chu Modbus-RTU communication hmangin pakhat hnu pakhatin an inzawm khawm a, chutah chuan MODBUS-TCP/SNMP/4G(wireless) hmangin system-ah data chu battery monitoring system-ah upload a ni a, system-a data awm zawng zawng chu a lang vek a ni. System emaw mobile APP hmanga battery hriselna dinhmun enkawl leh enfiah chu engtik lai pawhin, hmun tinah pawh a awlsam hle.


4. Battery Health Trend thlirletna atan Historical Data leh Data Curve te enfiah thin ang che


Real-time data a enfiah a, i battery string-a cell tinte historical data a dahkhawm bawk. Chuvangin maintenance hian real-time data/alarm atang hian battery hriselna a teh mai bakah historical data curve atang pawhin battery harsatna awm tur chu a hrilhfiah thei bawk.


5. A hun taka Alarm


Battery-a thil danglam tak a awm chuan system chuan maintenance-ah a hun takah alarm a thawn chhuak ang. Battery monitors sensor tha ber ber chuan system tana battery health data a khawlkhawm thei a ni. Data a san lutuk chuan system chuan contact person hnenah Email/SMS alarm a thawn ang. Hetihlai hian cell sensor chu red light nen a lo awm dawn a, hei hian maintenance-in battery room chhunga battery buaina chu rang taka a hmuh theih nan a pui dawn a ni.


DFUN atanga Battery Monitor tha ber ber te


DFUN hi market-a hmahruaitu brand a ni a, lead-acid/Ni-cd/Lithium battery hriselna enfiah nan battery monitor quality danglam tak tak a siam chhuak thin. Application hrang hrang leh site mamawh hrang hrang a zirin solution hrang hrang an pe thei a ni. A hnuaia mi ang hian data center atana software kan rawn tarlang dawn a ni.


• PBAT-Gate a ni


PBAT-Gate-ah a awm battery monitor system  hi data center tenau tak tak tan a siam a ni. He battery monitor-a thil pawimawh thenkhat chu:

• Webpage software build-in, battery data information zawng zawng real-time monitoring, third-party software nena inzawm lo, hman awlsam, engineer te tan pawha awlsam.

• Data center te tak te battery room atan a suit ≦480pcs.

• 2V, 4V, 6V, 12V lead-acid battery te chu enfiah thin ang che

• Auto-balancing hnathawh a ni.

• Email/SMS alarm a thawn chhuak.


• PBMS9000+DFCS4100 hmanga tihchhuah a ni 


PBMS9000 + DFCS4100 solution hi data center lian tak tak tan a tha hle. He solution-a thil pawimawh thenkhat chu a hnuaia mi ang hian a ni:

• Max. UPS khatah string 6 a awm a;

• DFCS4100 hian cloud monitoring software leh site hrang hrang centralized monitoring atang hian battery 50,000+ max monitoring a ti thei a;

• 2V, 4V, 6V, 12V lead-acid , emaw 1.2V Ni-cd battery te enkawl;

• Auto-balancing hnathawh dan;

• Email/SMS alarm a thawn chhuak.

Data center lian tak tak neitu tan chuan DFUN chuan PBMS9000 a siam a, hei hian battery hriselna chungchanga i lungkhamna tihziaawmna turin real-time monitoring a pe a ni. Maximum efficiency atan chuan flexible application a nei a, voltage hrang hrang pahnih hmangin a thawk a, chung zingah chuan separated string voltage leh ripple voltage te pawh a tel. Tin, auto sensor hmanga harsatna eng pawh target turin quick alarm i hmu thei bawk. Chuti a nih chuan engtin nge data center hrang hrang atan i thlan theih ang?


Battery monitor thlan hi thil awlsam a ni lo. Battery monitor zawng zawng hi a inang vek i ti mai thei, mahse chutiang chu a ni lo. Data center pakhat tana battery monitor tha ber chu data center dang tan chuan a tha ber lo mai thei. Ngaihtuah tur pawimawh thenkhat chu hetiang hi a ni:


1. Team industry lama tawnhriat rei tak nei, sumdawnna lama thawk tawh, thil siamtu hmingthang tak takte hnen atanga lei.

2. Battery monitor hian i application a handle theih ngei ngei tur a ni.

3. Battery monitor service leh siamthat nan eng nge mamawh tih hrethiam.

4. Testing leh quality assurance chungchang zawt rawh.

5. Brand hian spare parts a pe ngei ngei tur a ni a, chutiang chuan issue awm lovin i thlak thei ang.


Engvangin Nge DFUN hi kan thlan?


Data center-a battery monitor tha ber berte hian a awm theihna sang ber, battery temperature dik tak, voltage monitoring leh service life rei ber an pe tur a ni. Battery monitor thlan tur tha tak chu DFUN atanga siam te hi a ni. Rin tlak ber zinga mi angin battery management system manufacturers , DFUN hian product quality sang tak tak, state-of-the-art design, raw material quality tha zawk, special cable, R&D atana integrated laboratory, leh assembly technique hmasawn tak tak te a pe fo thin. Assembly zawng zawng hi kut hmanga tih a ni a, quality sang ber a nih theih nan a ni. Hei bakah hian battery monitoring system, backup power management system, leh energy storage system te an nei bawk.


Tawpna


Battery monitor tha tak i zawng a nih chuan, chu chuan i data center-a i battery te enfiahna kawngah hna ropui tak a thawk ang. Chutiang a nih chuan DFUN hi i ngaihtuah tur brand tha ber pawl a ni. Kum tin khawvel hmun hrang hrangah battery 200,000pcs an run leh enkawl thin. Customized service hmang hian i mamawh angin product & service danglam tak tak an pe thei bawk.


Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 a awm a.
  +86-756-6123188 ah zawhfiah theih a ni
 tih a ni  +86- 15919182362 a ni.

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni