1. Project hnuaia thil awm dan
Lead acid battery hi server room chhunga UPS core component a ni a, mahse UPS failure thlentu ber a ni bawk. Statistics atanga a lan dan chuan UPS failure 50% aia tam hi battery failure vang a ni. Real-time online monitoring tha tak leh battery dinhmun dik taka hriat theih dan tur chu a pawimawh zual hle.

2. Traditional Enkawlna (Traditional Maintenance) a ni
2.1.1. Maintenance hna tam lutuk leh thawktu indaih lohna inkara inhnialna.

2. Server room lian takah battery maintenance workload lian tak a awm avangin routine maintenance work chu mahni chauha tihfel a harsa hle.
2.2. Phased maintenance leh immediate failure inkara inhnialna.
Traditional maintenance hian mains electric a tihtawp chuan battery performance status leh emergency power supply hun chhung a nemnghet thei lo.
2.3. Difference performance hian battery chhiatna a tizual
Maintenance dik lo emaw, enkawl loh emaw, online floating charge-a voltage imbalance awm loh bakah, hun rei tak chhunga floating charge hnuaia awmte hian battery chhiatna a tizual ang a, battery dam rei zawng pawh nasa takin a ti tlem ang.

3. A chinfel dan
System Insiam dan (System Structure) a ni

4. Thil langsar tak
4.1 Online hmanga enkawl dan sem darh
PBMS6000 PRO hian 'one sensor for one battery' distributed structure a hmang a, darkar 24 chhung online-a real-time monitoring, a hun taka leh dik taka cell rualbanlote hmuhchhuah, hriattirna hmasa leh himna atana hlauhawm tihbo a ni.

4.2. Communication bus hmanga chak a ni
Battery monitoring module hian host bus power supply a hmang a, battery power a hmang lo a, battery kal lai voltage balance chu tha takin a vawng thei bawk.
4.3. Battery sensor ID address hriat theihna tur Auto-Sensing
Battery monitoring master hian battery cell sensor tinte chu automatic-in a zawng thei a, manual settings tam lutuk lovin communication address chu automatic-in a configure thei a, hei hian engineering workload leh configuration errors te chu a ti tlem thei hle.
4.4. Leakage enfiah a ni
+/- pole-a dah a nih chuan battery leakage a awm chuan battery leakage fault point chu rang tak leh automatic-in a orient ang.
4.5. Liquid level enfiah a ni
Battery liquid level dinhmun a enfiah thei a ni. Battery electrolyte chu normal range aia hniam a nih chuan master chuan liquid level a hniam lutuk chuan early warning a thawn chhuak thei a ni.
4.6. Online hmanga balance neih a ni
Battery impedance a inthlau avangin online float charge-a cell sensor tinte voltage a inthlau hle. Battery cell sensor inmil nen thuam a ni a, float charge voltage hniam nei monomer battery tan leh float charge voltage sang cell battery tan online pulse-type supplementary power a ti thei bawk.

5. Dilna hamthatna
PBMS6000 PRO battery online monitoring device hi power by communication bus distributed system hmanga siam a ni a, hei hian traditional battery maintenance leh testing-a tlakchhamnate a khum mai bakah maintenance time, manpower, material resources leh costs tam tak a humhim bawk. Chutih rual chuan battery chhia chu a hun takah a hmuchhuak thei a, a hre thei bawk a, accident lo turin a hmain a hriattir thei bawk.