A ziaktu: DFUN Tech Publish hun: 2023-02-02 A bul tanna: Hmun
1. Project background 10.1.
Lead acid battery hi server room-a UPS-a core component a ni a, mahse UPS hlawhchhamna bulpui ber a ni bawk. Statistics atanga a lan dan chuan UPS failure 50% aia tam hi battery a chhiat vang a ni. How to effectively real-time online monitoring leh battery dinhmun dik taka hriatthiam dan chu a pawimawh zual hle.
2. Traditional enkawl dan .
2.1 a ni. Maintenance hna tam lutuk leh staff tlakchhamna inkara inhnialna.
2. Server room lian takah hian battery enkawlna hna thawh tam tak a awm avangin routine maintenance hna chauh thawh zawh a harsa hle.
2.2 a ni. Phased maintenance leh immediate failure inkara inhnialna.
Traditional maintenance hian mains electricity tihtawp a nih chuan battery performance dinhmun leh emergency power supply hun chhung a nemnghet thei lo.
2.3 a ni. danglamna performance aggravate battery a chhiat chuan .
Maintenance dik lo emaw, enkawl loh emaw, online floating charge-a voltage imbalance bakah hun rei tak chhunga floating charge hnuaia awm chuan battery tihchhiatna a tizual lehzual ang a, battery dam chhung a ti tlem zawk bawk ang.
3. A chinfel dan tur .
System siam dan tur .
4. Feature .
4.1 Online-a enkawlna sem chhuah .
PBMS6000 Pro hian battery pakhata distributed structure atan 'one sensor a hmang a, darkar 24 chhung online-a real-time monitoring, a hun taka leh dik taka hmuhchhuah, disabled cells te chu a hmaa vaukhânna leh himna atana hlauhawm tihbo a ni.
4.2 a ni. Communication Bus hmanga power pek a ni.
Battery monitoring module hian host bus power supply a hmang a, battery power a hmang lo a, a running battery voltage balance chu a tha zawngin a vawng thei bawk.
4.3 a ni. Battery sensor ID address a awm chuan auto-sensing a awm bawk.
Battery Monitoring Master hian battery cell sensor tin chu automatic in a zawng thei a, communication address chu manual setting tam lutuk lovin automatic in a configure thei a, hei hian engineering workload leh configuration error te chu a ti tlem thei hle.
4.4 a ni. Leakage enkawl dan .
+/- pole-a install a nih chuan battery leakage a thlen chuan rang tak leh automatic-in battery leakage fault point chu a orient ang.
4.5 a ni. Liquid level enkawl dan tur .
Battery liquid level status a enfiah thei bawk. Battery electrolyte chu normal range aia hniam a nih chuan master chuan liquid level a hniam lutuk chuan early warning a thawn chhuak thei a ni.
4.6 a ni. Online balancing 10.1.
Battery impedance inang lo tak avangin online float charge-a cell sensor tinte voltage chu a inthlau hle. Battery cell sensor inmil hmanga thuam a nih avangin online pulse-type supplementary power chu monomer battery float charge voltage hniam tak nei tan a ti thei a, float charge voltage sang tak nei cell battery tan pawh a ti thei bawk.
5. Dilna atanga hlawkna .
PBMS6000 PRO Battery Online Monitoring Device hi communication bus distributed system hmanga power hmanga siam a ni a, hei hian battery enkawl leh test-na lama harsatna awmte chu a khum mai bakah, enkawlna hun, manpower, material resources leh cost tam tak a humhim bawk. Chutih rual chuan a hun taka failure battery te pawh a hmuchhuak thei a, a hriat theih bawk a, accident a thlen loh nan early warning a nei thei bawk.
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .
Lead acid battery te dam rei theihna tura battery enkawlna chanvo .
DFUN Battery Monitoring System explore: Battery enkawlna kawnga thil awm thei tawp nei lo hawn theih
10 Signs I sumdawnna chuan Battery Monitoring System (BMS) a mamawh nghal vat a.