Infrastructure thar a lo thang zel avangin data center industry pawh a lo thang chak hle a, a lo thang zel bawk. Data centre sakna tur hian ultra-large scale leh security sang tak lam a pan mek a ni. Battery hi data center-a backup power supply system-a thil pawimawh tak a nih angin, emergency-a power supply chhunzawm zel leh normal taka hnathawh theihna turin hmun pawimawh tak a chang a ni. Battery chu a hnathawh dan tur tha ber a nih theih nan battery monitoring system-ah safety design mamawh khauh tak siam a ni a, a bik takin safety redundancy design-ah a innghat a ni. Heng safety design mamawhna te hi a bik takin kawng hnih ah a lang a, chungte chu power safety leh communication safety te an ni.
1. Power himna tur redundancy design .
Master device-a power system atana redundancy backup design kalpui hi mainstream practice a ni a, stable taka hnathawh theihna tur kawng pawimawh ber a ni. Low-probability, mahse high-impact power failures, hun rei tak chhunga operation-a a awm theihna hmuna awm thei tur chu hmachhawn tur chuan, master device-a power system dual power supply design chu mutual backup angin a thawk a, power supply rintlak tak a nei thei a ni.
Dual power supply leh single power supply tehkhin dan .
2. Data thawn chhuah dan himna atana hman tur redundancy design .
Battery bank lian tham hman chungchangah chuan, routine maintenance leh emergency-a battery-te real-time status a hun taka hriatthiam a pawimawh hle. Hei hian data lakkhawm chak leh refresh rate a mamawh a ni. Chutiang dinhmunah chuan network latency emaw congestion emaw a awm thei a, chu chuan system response leh data blockage a ti hniam thei a, maintenance leh issue resolution efficiency nasa takin a nghawng thei a ni. Dual Ethernet ports design hian heng harsatnate hi a tikhawlo thei a, command execution leh data query process mumal tak a awm theih nan a pui thei a ni.
Dual Ethernet port leh single Ethernet port te khaikhin dan .
3. Inbiakpawhna Safety Redundancy Design .
Long-term system hman chhung hian, cell sensor failure-a low-probability event atan chuan ring communication design chu technically-in hman theih a ni. He design hian cell sensor leh master device inkarah communication loop a siam a, chu chuan individual cell sensor a chhiat chuan midangte inbiakpawhna a tibuai lo tih a tichiang a ni.
Ring communication a thlawp a, point pakhat chauh a nei a ni.
Disconnection pakhat zel cell sensor inbiakpawhna a nghawng lo .
Data Center industry-in high-security application demand a hmachhawn mek lai hian safety redundancy design hi DFUN product design-ah ngaihtuah tur pawimawh tak a ni fo. thil siamte tihhlawhtlin leh customer-te nena ding reng a, an pain points thuk taka hriatthiamna nei, leh product innovation lama insist-na hmangin, DFUN hian a customer te rinna pek let leh a tum a ni.
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .