PBMS9000 a ni.
Dfun a ni a.
- Darkar 24/7 chhung on-line monitoring & remote alarm notification
- UPS leh data center application-ah hman theih a ni.
- Lead-acid emaw multi-pole battery emaw teh rawh .
- Ring communication, inbiakpawhna a chhiat chuan sensor dang communication a nghawng dawn lo
- Battery voltage, current, impedance, insulation resistance, ripple current & voltage, SOC, SOH, etc. te enfiah.
- Modbus, SNMP, MQTT leh IEC61850 protocol te thlawp rawh.
- Battery sensor ID address a hman tur auto-sensing a awm bawk.
- Power tihtawp loh nan dual-source .
- Anti-interference design, high-frequency UPS nena inzawm theihna tur support
- IEEE 1188-2005 zawm tur a ni.
Battery chi hrang hrang . | Lead Acid Battery, Multi-pole Battery 1000 a awm bawk. |
Dilna | Data Center, UPS 1000 a awm bawk. |
CPU 10 a ni. | Arm Cortex A7 528MHz 1000 a ni. |
Hriatrengna | 512MB flash, 4g EMMC+ 8G TF Memory card a ni. |
String zawng zawng . | Max.6 strings, total≤420pcs |
Cell voltage 1000 a ni. | 2V, 6V, 12V a ni. |
Up-link inbiakpawhna a awm bawk. | 2 Ethernet Ports (10/100m), Modbus-TCP, SNMP, IEC61850 1 RS485 Port, Modbus-Rtu, Baudrate: 9600bps, 19200bps, 38400bps (a duh duh) |
Down-link hmanga inbiakpawhna . | Channel 6 RJ11 ports, port pakhat theuh max. Battery ≤ 70, total max. 420pcs a ni. |
Inbiakpawhna Protocol 1.1. | Modbus, SNMP, MQTT leh IEC61850 te a awm bawk. |
Baudrate a ni a. | 1200bps ~ 115200bps a ni. |
Sensor LED hian a tarlang a . | Green: Normal status Red: A dik lo. |
HMI 2019 a ni. | 10.1- Inch touch-screen HMI chu a awmna hmuna a lan dan leh a hnathawh dan (optional) a ni. |
Operation environment 1.1. | Hnathawktu Temperature: -15°C ~ 55°C A dahna tur hmun zau zawng: -40°C ~ 70°C Humidity: 5% ~ 95% Condensing ni lo |
Certification 1000 a ni. | EMC, ROHS, CE, ISO9001, ISO14001, ISO45001 te chu a rawn lang leh ta. |
HMI-9000 a ni.
10.1-inch touch screen HMI tualchhung display module a awm bawk.
PBAT-Box-260 a ni.
PBMS9000 leh HMI-9000 te tan pre-wiring atan cabinet hman a ni.
PBMS-VM 1000 a ni.
A tehna layer string voltage sensor .
H-THDRJ45 a ni.
Ambient Temperature & Humidity Sensor .
PBMS-IM 1000 a ni.
DC Insulation Resistance Sensor a ni a, a hmanna tur a awm lo.
- Darkar 24/7 chhung on-line monitoring & remote alarm notification
- UPS leh data center application-ah hman theih a ni.
- Lead-acid emaw multi-pole battery emaw teh rawh .
- Ring communication, inbiakpawhna a chhiat chuan sensor dang communication a nghawng dawn lo
- Battery voltage, current, impedance, insulation resistance, ripple current & voltage, SOC, SOH, etc. te enfiah.
- Modbus, SNMP, MQTT leh IEC61850 protocols te thlawp rawh.
- Battery sensor ID address a hman tur auto-sensing a awm bawk.
- Power tihtawp loh nan dual-source .
- Anti-interference design, high-frequency UPS nena inzawm theihna tur support
- IEEE 1188-2005 zawm tur a ni.
Battery chi hrang hrang . | Lead Acid Battery, Multi-pole Battery 1000 a awm bawk. |
Dilna | Data Center, UPS 1000 a awm bawk. |
CPU 10 a ni. | Arm Cortex A7 528MHz 1000 a ni. |
Hriatrengna | 512MB flash, 4g EMMC+ 8G TF Memory card a ni. |
String zawng zawng . | Max.6 strings, total≤420pcs |
Cell voltage 1000 a ni. | 2V, 6V, 12V a ni. |
Up-link inbiakpawhna a awm bawk. | 2 Ethernet Ports (10/100m), Modbus-TCP, SNMP, IEC61850 1 RS485 Port, Modbus-Rtu, Baudrate: 9600bps, 19200bps, 38400bps (a duh duh) |
Down-link hmanga inbiakpawhna . | Channel 6 RJ11 ports, port pakhat theuh max. Battery ≤ 70, total max. 420pcs a ni. |
Inbiakpawhna Protocol 1.1. | Modbus, SNMP, MQTT leh IEC61850 te a awm bawk. |
Baudrate a ni a. | 1200bps ~ 115200bps a ni. |
Sensor LED hian a tarlang a . | Green: Normal status Red: A dik lo. |
HMI 2019 a ni. | 10.1- Inch touch-screen HMI chu a awmna hmuna a lan dan leh a hnathawh dan (optional) a ni. |
Operation environment 1.1. | Hnathawktu Temperature: -15°C ~ 55°C A dahna tur hmun zau zawng: -40°C ~ 70°C Humidity: 5% ~ 95% Condensing ni lo |
Certification 1000 a ni. | EMC, ROHS, CE, ISO9001, ISO14001, ISO45001 te chu a rawn lang leh ta. |
HMI-9000 a ni.
10.1-inch touch screen HMI tualchhung display module a awm bawk.
PBAT-Box-260 a ni.
PBMS9000 leh HMI-9000 te tan pre-wiring atan cabinet hman a ni.
PBMS-VM 1000 a ni.
A tehna layer string voltage sensor .
H-THDRJ45 a ni.
Ambient Temperature & Humidity Sensor .
PBMS-IM 1000 a ni.
DC Insulation Resistance Sensor a ni a, a hmanna tur a awm lo.
PBMS9000 solution demo a ni a, a hlawhtling hle.
Website:http://120.198.218.87:18089 ah a awm a.
Demo password atan contact information te chu dah la.
PBMS9000 solution demo a ni a, a hlawhtling hle.
Website:http://120.198.218.87:18089 ah a awm a.
Demo password atan contact information te chu dah la.