In » Thil siam chhuah te » Biru » PBMS9000Pro 110V 220V Substation Battery Monitor Solution hmanga siam a ni

PBMS9000Pro 110V 220V Substation Battery Monitor Solution hmanga siam a ni

DFUN siam PBAT71 battery cell sensor nei PBMS9000Pro battery monitoring solution hian battery string te chu a mah ngeiin a diagnose thei a, operating status real-time monitoring hmangin a corresponding maintenance chu automatic in a ti thei bawk. PBAT71 cell sensor hi communication cable hmanga power pek a nih avangin battery cell atang hian power consumption a awm lo a, hei hian battery cells te chu rintlak taka hnathawh theihna a tichiang thei a ni. Module hian electrolyte leakage tehna function a nei a, hei hian battery pole emaw gas vent emaw-ah online leakage monitoring a ti thei a ni.
A awm theihna:
A zat:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp a insem theihna tur a ni
sharethih hi share theih a ni
  • PBMS9000Pro a ni

  • DFUN a ni


PBMS9000Pro Battery Monitoring System hmanga hman tur a ni

PBMS9000 Pro Battery Monitoring System hmang hian battery bank hrang hrangte online-a enfiah theih a ni a, battery bank leh battery cell performance kimchang taka teh leh hriat theih a ni a, battery failed battery display leh alarm hmanga battery detection leh failure anticipation detection automation a hriat theih nan hman theih a ni bawk. He system hian battery bank chu a self-diagnose thei a, battery cell operating status leh operating parameter hrang hrangte real-time monitoring hmangin automatic in corresponding maintenance a ti thei a, network hmangin remote signaling, remote measurement, leh remote control te chu a tihlawhtling thei bawk. He system hian battery bank hnathawh dan tak tak leh hriselna dinhmun chu a hun takah a hrethiam thei a, battery bank chhunga harsatna awmte chu a hun takah a hmuchhuak thei a, automatic maintenance function pawh a hrethiam thei bawk. Balance function hian battery bank chu floating charge laiin voltage balance a vawng reng a, battery cell tinte chu a tha ber berah a dah a, battery backup hun leh operating life a ti tha a, battery hnunglam chu a hun takah a hmuchhuak a, alarm a siam bawk a, hei hian manpower leh material resources ang chi maintenance cost nasa takin a tihtlem a, battery hmanna himna a ti tlem a, accident rate a ti tlem a, effective takin energy a humhim a, emission a tihtlem bawk a, chutah chuan a hmangtu tan economic leh social benefits tha tak a siam a ni.

PBMS9000Pro Battery Monitoring System chu Utility Heading atan hman a ni



PBAT71-02 / PBAT71-12 Battery Cell Sensor hmanga siam a ni


- PBAT71-02 hi 2V Lead-Acid battery emaw 1.2V Ni-Cd battery emaw atan hman theih a ni

- PBAT71-12 hi 12V Lead-Acid battery atan hman theih a ni

- Battery pakhat zel voltage, a chhunga temperature (negative pole), impedance (ohmic value) te enfiah thin ang che.

- Mimal battery state of charge (SOC), state of health (SOH) te chhut chhuah

- Battery leakage leh liquid level monitoring a support (a duh chuan)

- Communication bus hmanga powered, battery power hmang lo

- Auto-balancing a ni

PBMS9000Pro Battery Monitoring System for Utility PBMS9000 Pro Battery Monitoring System hmang hian battery bank hrang hrangte online-a enfiah theih a ni a, battery bank leh battery cell performance kimchang taka teh leh hriat theih a ni a, battery failed battery display leh alarm hmanga battery detection leh failure anticipation detection automation a nihzia hriatchhuah theih a ni bawk. He system hian battery bank chu a self-diagnose thei a, battery cell operating status leh operating parameter hrang hrangte real-time monitoring hmangin automatic in corresponding maintenance a ti thei a, network hmangin remote signaling, remote measurement, leh remote control te chu a tihlawhtling thei bawk. He system hian battery bank hnathawh dan tak tak leh hriselna dinhmun chu a hun takah a hrethiam thei a, battery bank chhunga harsatna awmte chu a hun takah a hmuchhuak thei a, automatic maintenance function pawh a hrethiam thei bawk. Balance function hian battery bank chu floating charge laiin voltage balance a vawng reng a, battery cell tinte chu a tha ber berah a dah a, battery backup hun leh operating life a ti tha a, battery hnunglam chu a hun takah a hmuchhuak a, alarm a siam bawk a, hei hian manpower leh material resources ang chi maintenance cost nasa takin a tihtlem a, battery hmanna himna a ti tlem a, accident rate a ti tlem a, effective takin energy a humhim a, emission a tihtlem bawk a, chutah chuan a hmangtu tan economic leh social benefits tha tak a siam a ni. PBMS9000Pro Battery Monitoring System chu Utility Heading PBAT71-02 / PBAT71-12 Battery Cell Sensor atan hman a ni


PBMS9000Pro Battery Monitoring System hmanga Utility System Structure siam dan tur ruahmanna siam a ni

PBMS9000Pro Battery Monitoring System hmanga Utility System Structure siam dan tur ruahmanna siam a ni


PBMS9000Pro Solution Demo

Website ah hian:A rilru a hah lutuk chuan a rilru a buai em em a. 120.198.218.87:18089


Demo password atan contact information dah la. 

Min rawn biak theih reng e



Hma chiah: 
Dawtchiah: 
Min rawn biak theih reng e
Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah zawhfiah theih a ni

A thuneihna chu 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni