Battery chakna leh hnathawh dan tehfung leh tehfung siam.
Battery hian operational requirement beisei angin a tlin theih nan.
Capacity testing hmangin battery string State of Health (SOH) dik takin man la, battery tha lo tak takte chu hriatchhuah rawh.
String battery hriselna zawng zawng tihchangtlun nan.
Backup power rintlak leh tangkai tak a nih theih nan.
Voltage hniam live equipment hmanga hnathawh hunah electric shock ven nan insulated electrical tools hmang thin ang che.
Battery terminal te chu uluk takin label la, short circuit a awm loh nan wiring dik tak enfiah rawh.
Direct current (DC) short circuit leh grounding khap tlat.
Hmun hlat zawng vawng reng tur leh hmanraw nung atanga inthiarfihlim dan tur ruahmanna kalpui tur.
Manual capacity testing hian personnel te chungah demand sang tak a siam a ni. Capacity testing process hian hmanrua te hnathawhna atana him leh rintlakna atan a tha lo hle. Operating time rei tak leh hmanraw tam tak a awm avangin routine capacity testing chu specification angin tihfel a harsa hle.
Entirnan, power supply bureau pakhat chuan voltage level hrang hranga substation 62 a enkawl a, chung zawng zawng chu dual DC system hmanga thuam vek a ni a, chu chu battery string zawng zawng 124 hman a ni tihna a ni. Comprehensive statistics atanga a lan dan chuan heng string zinga 66 hi kum nga chuang zet an thawk tawh a, 58 chu kum nga aia rei lo an thawk tawh bawk. Hei hian kum tin a vaiin battery string 95 vel chu capacity discharge testing neih a ngai tih a tilang. Kar tin personnel group pahnihin capacity discharge testing an neih chuan thla ruk chhung a ngai dawn a ni.
Battery set-te tana remote online capacity testing system hian him tak leh rintlak takin remote discharge capacity test a ti thei a, battery thawk tha lote chu a hmain a hriat theih phah a ni. Tin, a hnathawh laiin open-circuit fault nei battery te hnenah current kal zel a pe thei bawk a, chu chuan battery maintenance hna chu automation leh intelligent takin a enkawl thei a ni.
DFUN a lo thanglian ta a ni Telecom Power Systems tana remote online capacity testing solution hian hna hrang hrang a thlunzawm a, chung zingah chuan remote capacity testing, energy-efficient discharge, intelligent charging, battery monitoring, leh battery activation te pawh a tel. He solution hian manual inspection-a hun rei tak leh hnathawk tam tak senga harsatna te, disconnection leh reconnection chungchangah offline capacity testing harsatna te, leh hmun darh zau tak enkawl harsatna te chu a hlawhtling hle a ni. Substation, control center, leh energy storage power plant ang chi system atan a tha hle.

Data Center-a Battery Fire: Battery Monitoring System hmanga a ven dan
Battery Siamtu Leh Distributor te hian Smart Battery Monitoring System lam an pan chhan
Data Center Battery Kang hian Intelligent BMS mamawhna a lantir | DFUN PBMS9000 + PBAT61 a ni
Battery Monitoring: Industries hrang hranga Power Security lungphum
X Data Center Fire: System-Level-a invenna atana Wake-Up Call a ni