In » CHANCHINTHAR » Industry chanchin thar . » Hlutna Article » Remote Online Capacity Testing pawimawhzia

Remote Online Capacity Testing pawimawhzia

Zawhna zawt rawh

facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

Remote Online Capacity Testing pawimawhzia



01 Battery Capacity Testing tum ber


  • Battery chakna leh hnathawh dan tehfung leh tehfung siam.

  • Battery hian beisei angin operational requirement a tlin theih nan.

  • Capacity testing hmangin battery string State of Health (SOH) dik takin man la, battery tha lo tak takte chu hriatchhuah rawh.

  • String battery hriselna zawng zawng tihchangtlun nan.

  • Backup power rintlak leh tangkai tak a nih theih nan.


02 Tunah hian Manual Capacity Testing-ah hian eng harsatna nge a hmachhawn?


  • Voltage hniam live equipment hmanga hnathawh hunah electric shock ven nan insulated electrical tools hmang thin ang che.

  • Battery terminal te chu uluk takin label la, short circuit a awm loh nan wiring dik tak enfiah rawh.

  • Direct current (DC) short circuit leh grounding khap tlat.

  • Hmun hlat zawng vawng reng tur leh hmanraw nung atanga inthiarfihlim dan tur ruahmanna kalpui tur.


Manual capacity testing hian personnel te chungah demand sang tak a siam a ni. Capacity testing process hian hmanrua te hnathawhna atana him leh rintlakna atan a tha lo hle. Operating time rei tak leh hmanraw tam tak a awm avangin routine capacity testing chu specification angin tihfel a harsa hle.


Entirnan, power supply bureau pakhat chuan voltage level hrang hranga substation 62 a enkawl a, chung zawng zawng chu dual DC system hmanga thuam vek a ni a, chu chu battery string zawng zawng 124 hman a ni tihna a ni. Comprehensive statistics atanga a lan dan chuan heng string zinga 66 hi kum nga chuang zet an thawk tawh a, 58 chu kum nga aia rei lo an thawk tawh bawk. Hei hian kum tin a vaiin battery string 95 vel chu capacity discharge testing neih a ngai tih a tilang a ni. Kar tin personnel group pahnihin capacity discharge testing an neih chuan thla ruk chhung a ngai dawn a ni.


03 Remote Online-a Capacity Testing Hman Dan


Battery set-te tana remote online capacity testing system hian him tak leh rintlak takin remote discharge capacity test a ti thei a, battery thawk tha lote chu a hmain a hriat theih phah a ni. Tin, a hnathawh laiin open-circuit fault nei battery te hnenah current kal zel a pe thei bawk a, chu chuan battery maintenance hna chu automation leh intelligent takin a enkawl thei a ni.


DFUN a lo thanglian ta a ni Telecom Power Systems tana remote online capacity testing solution hian hna hrang hrang a thlunzawm a, chung zingah chuan remote capacity testing, energy-efficient discharge, intelligent charging, battery monitoring, leh battery activation te pawh a tel. He solution hian manual inspection-a hun rei tak leh hnathawk tam tak senga harsatna te, disconnection leh reconnection chungchangah offline capacity testing harsatna te, leh hmun darh zau tak enkawl harsatna te chu a hlawhtling hle a ni. Substation, control center, leh energy storage power plant ang chi system atan a tha hle.


DFUN Remote Online-a Capacity Testing hmanga thil tih theih a ni


Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 a awm a.
  +86-756-6123188 ah zawhfiah theih a ni
 tih a ni  +86- 15919182362 a ni.

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni