Alesi Nàtia Batria Dzi Kpɔkpɔ ƒe Dɔwɔɖoɖo Na Ŋusẽdɔ Veviwo

Bia nya

facebook dzi mamã ƒe dzesi
twitter dzi mamã ƒe dzesi
fliwo mama ƒe dzesi
wechat mama ƒe dzesi
linkedin mama ƒe dzesi
pinterest mama ƒe dzesi
whatsapp mamã ƒe dzesi
sharethis mamã ƒe dzesi

Ele be batri ƒe ŋkuléleɖenuŋu ƒe ɖoɖo nyuitɔ nasɔ kple batri ƒe atikewɔwɔ, ɖoɖoa ƒe elektrikŋusẽ, teƒea ƒe nɔnɔme, beléle na eƒe mɔnu, kadodo ƒe xɔtuɖaŋu, kple kakaɖedzi ƒe nudidi siwo le dɔwɔnua me.

Le nyatakakadzraɖoƒewo, dɔwɔƒe suewo, telefonkadodowo ƒe teƒewo, ʋuɖoɖo ƒe ɖoɖowo, kple dɔwɔƒewo gome la, batriwo dzi kpɔkpɔ ƒe ɖoɖo si sɔ na ŋusẽzazã veviwo kpena ɖe dɔwɔlawo ŋu be woade dzesi lãmenugbagbevi siwo gbɔdzɔ, dzoxɔxɔ si mesɔ o, kadodo ƒe kuxiwo, kple charge ƒe nyawo hafi elektrikŋusẽ si woatsɔ akpɔ wo tae hiã. Mɔfiame sia ɖe tiatiawɔblɔɖe ƒe dzidzenu vevitɔwo kekeake me.

Batriki dzi kpɔkpɔ ƒe ɖoɖo na nyatakakadzraɖoƒewo ƒe dɔwɔƒe suewo kple telefonkadodowo ƒe nyatakakadzraɖoƒewo

Dze egɔme kple Afɔku si Dzi Wòle Be Nàɖu

Dɔwɔƒe vovovowo dzea ŋgɔ batri ƒe afɔku vovovowo. Nyatakakadzraɖoƒe ate ŋu atsɔ UPS ƒe anyinɔnɔ kple eƒe ɖekawɔwɔ kple DCIM aɖo nɔƒe gbãtɔ. Utility substation ateŋu abia Ni-Cd ƒe kpekpeɖeŋu kple kadodo kple SCADA. Telefonkadododɔwɔƒe ate ŋu ahiã na adzɔge ʋĩ ƒe ɣlidodowo kple nutoa me nyatakakawo dzraɖoƒe na nyatakakadzraɖoƒe siwo dzi womekpɔna o. Ami kple gas dɔwɔƒewo ate ŋu abia dɔwɔnu siwo ŋu wotrɔ asi le na nuto sesẽwo alo esiwo gblẽa nu le ame ŋu.

Hafi nàtsɔ adzɔnuwo asɔ kple wo nɔewo la, ɖe nusiwo ado tso batri ƒe gbagbã me me:

  • Aleke gbegbee agbaa le vevie, eye ɣeyiɣi didi kae nyatakakadzraɖoƒea ate ŋu ado dzi atsɔ awɔ dɔe?
  • Ðe woda batriawo ɖe teƒe ɖeka alo le teƒe didi geɖea?
  • Dodokpɔ kawoe wòle be woade dzesii hafi woaɖe asi le eŋu kpata?
  • Amekawoe xɔa ɣlidodo, eye aleke gbegbee wòle be woawɔ nu kabae?

Ŋuɖoɖoawoe afia nenye be dɔa hiã na ka ƒe dzikpɔkpɔ veviwo alo batri dzi kpɔkpɔ ƒe ɖoɖo si me kɔ nyuie le lãmenugbagbeviwo ƒe ɖoɖo nu si me ɣlidodo siwo gblɔa nya ɖi kple dɔdzikpɔkpɔ le teƒe ɖeka.

1. Tia Cell-Level Monitoring hena Vodadawo Didi Kaba

Ðeko woate ŋu aka ɖe batri ƒe ka dzi abe eƒe lãmenugbagbevi alo mɔxenu si gbɔdzɔ wu ene. Ka ƒe elektrikŋusẽ ate ŋu adze abe ɖe wòsɔ ene ne batri ɖekaɖeka ƒe tsitretsitsi le ememe lolo, dzoxɔxɔ si mesɔ o, alo eƒe dzodzo ƒe ŋutete dzi ɖe kpɔtɔ gɔ̃ hã.

Lãmesẽnyawo dzi kpɔkpɔ le lãmenugbagbeviwo ƒe ɖoɖo nu nana be beléle na batriwo ƒe ƒuƒoƒowo te ŋu kpɔa batri ɖesiaɖe. Dzidzenu veviwo ate ŋu anye:

  • Ame ɖekaɖekawo ƒe lãmenugbagbevi alo block voltage
  • Ememe tsitretsitsi alo impedance ƒe nɔnɔme
  • Batri ƒe nuwuƒe ƒe dzoxɔxɔ
  • Ka ƒe ʋuʋudedi
  • Charge kple discharge fifia
  • Float kple ripple fifia
  • SOC kple SOH
  • Yame ƒe dzoxɔxɔ kple fafa

Bia zi nenie wodzidzea nu, nenye be wodzraa nuxexlẽwo ɖo abe nusiwo le edzi yim ene, eye nenye be nuƒolanɔƒea tsɔa batri ɖesiaɖe sɔna kple eƒe gɔmedzedze kple ka susɔea hã.

Batri si gbɔdzɔ si wokpɔ to lãmenugbagbeviwo ƒe elektrikŋusẽ ƒe dzoxɔxɔ kple ememe tsitretsitsi dzi kpɔkpɔ me

2. Kpe Ðe Batri ƒe Dzɔdzɔmeŋusẽŋununya Kple Dɔwɔɖoɖoa ƒe Ðekawɔwɔ Ŋu

Ele be ɖoɖo si wotia la nado alɔ batri ƒe dɔwɔwɔ ŋutɔŋutɔ, elektrikŋusẽ si woyɔna be elektrikŋusẽ, ka ƒe ɖoɖo, kple lãmenugbagbevi siwo ŋu wole ŋku lém ɖo ƒe xexlẽme.

VRLA ƒe Batriwo

Le 2V, 6V, kple 12V VRLA batriwo gome la, elektrikŋusẽ, ememe tsitretsitsi, dzoxɔxɔ, fifia, kple ɣeyiɣi didi ƒe nɔnɔme me dzodzro le vevie. Ememe tsitretsiɖeŋu si le dzidzim ɖe edzi alo dzoxɔxɔ ƒe tɔtrɔ si le dzidzim ɖe edzi ate ŋu ana woaxlɔ̃ nu kaba le gbegblẽ ŋu, gake ele be woada dzesi siawo kpɔ ɖekae tsɔ wu be woazã wo abe dzidzenu siwo woɖe ɖe aga atsɔ aɖɔli wo ene.

Ni-Cd Batriwo ƒe Dɔwɔnuwo

Ni-Cd batri gadzraɖoƒewo bɔ ɖe elektrikŋusẽdɔwɔƒe suewo, elektrikdɔwɔƒewo, ketekemɔwo, kple dɔwɔƒewo ƒe DC-mɔ̃wo me. Kpɔe ɖa be ŋkuléleɖenuŋu ƒe xɔtunua doa alɔ 1.2V lãmenugbagbeviwo kple lãmenugbagbevi ƒe xexlẽme bliboa le ka ɖesiaɖe me. Voltage ƒe dadasɔ, dzoxɔxɔ, charge ƒe nuwɔna, kple ɣeyiɣi didi ƒe nɔnɔmewo ɖea vi ŋutɔ na atike sia.

Lead-Acid Batri siwo Tsi Tsi

Batriki siwo tsi yɔ ate ŋu abia be woawɔ dɔ bubuwo abe elektrikŋusẽ ƒe agbɔsɔsɔ, tsi si le dodom, kple kadodoa dzi kpɔkpɔ ene. Kpɔ egbɔ be woate ŋu atsɔ sensor siawo awɔ ɖeka kple dɔdzikpɔkpɔ ƒe mɔnu ɖeka ma ke.

Lithium-Ion Batriwo ƒe Dɔwɔnuwo

Le lithium-mɔ̃wo gome la, na eme nakɔ nenye be dɔa bia be woawɔ ŋkuléleɖenuŋu ƒe ɖoɖo si le eɖokui si, kadodo kple batri ƒe BMS, alo dzikpɔkpɔ le teƒe ɖeka le batri ƒe ŋkɔ kple teƒe geɖewo.

3. Da Nuɖoanyia ƒe Xɔtuɖaŋu Bliboe kpɔ

(Nyatakakadzraɖoƒe abe nufiame ene)

Zi geɖe la, egbɔkpɔnu blibo lɔa lãmenugbagbeviwo ƒe sensorwo, kadzidzemɔ̃wo, dziɖunu alo agbonu, kadodomɔnu, kple dɔdzikpɔmɔ̃wo.

Ne èle xɔtuɖaŋua me tom la, kpɔe ɖa be:

  • Lãmenugbagbeviwo kple ka siwo sɔ gbɔ wu si wodo alɔe le dziɖula ɖesiaɖe me
  • Kekeɖenudɔwɔwɔ na batri siwo woatsɔ akpe ɖe eŋu le etsɔme
  • Nutoa me nudzraɖoƒe ƒe ŋutete le network ƒe nutsotso me
  • Nyatakakawo ƒe ɖekawɔwɔ le network la gbugbɔgaɖo anyi vɔ megbe
  • Ðekawɔwɔ kple dɔ siwo woma kple esiwo wowɔna le teƒe geɖe
Batri dzikpɔkpɔ ɖoɖo ƒe xɔtuɖaŋu kple cell sensors controller gateway kple software platform (Data center abe nufiame ene)

4. Dzro Alarm ƒe Nyonyome Me, Menye Alarm ƒe Agbɔsɔsɔme Ko O

Ele be ŋkuléleɖenuŋu ƒe mɔnu natrɔ dzidzenuwo woazu nyatakaka siwo ŋu woate ŋu awɔ dɔ le. Alarm geɖe akpa nana alarm la ɖeɖi tea ame ŋu, evɔ dzidzenu ɖeka si woɖo ɖi ate ŋu ato eƒe gbegblẽ vivivi ŋu.

Di dɔwɔwɔwo abe:

  • Nuxlɔ̃ame, ɣlidodo, kple dzidzenu veviwo
  • Dzesi siwo woate ŋu atrɔ asi le le batri ƒomevi kple teƒe si wole nu
  • Ʋɔtru siwo wotu ɖe nɔnɔme dzi kple tɔtrɔ ƒe agbɔsɔsɔme me dzodzro
  • Alarm heheɖemegbe kple hayahaya ƒe susuŋudɔwɔwɔ
  • Teƒe si tututu wòle, ka, kple batri ƒe dzesidede
  • Email, SMS, platform, kple teƒea ƒe alarm tiatia
  • Alarm ŋutinya kple lɔlɔ̃ ɖe edzi

Menye gbedasi si nye be asixɔxɔ aɖe wu seɖoƒe aɖe koe nye ɣlidodo nyuitɔ kekeake o. Ele be wòagblɔ afisi kuxia le, alesi gbegbe wòsesẽe, kple nyatakaka siwo trɔ na dɔwɔƒea.

5. Kpɔ Nyatakakawo Nana Kple Beléle Na Dɔwɔwɔ Siwo Wogblɔ Do Ŋgɔ Me

Esi wònye be zi geɖe la, batri ƒe gbegblẽ vivivi ta la, ele be nuƒolanɔƒea natsɔ nuxexlẽ siwo li fifia asɔ kple gɔmedzedze siwo woda ɖe eme, ɣeyiɣi siwo va yi, kple lãmenugbagbevi bubu siwo le ka ma ke me.

Nyatakaka siwo ŋu viɖe le dometɔ aɖewoe nye:

  • Batriki ƒe lãmesẽ ŋuti nyatakaka
  • Lãmenugbagbeviwo ƒe ʋuʋudedi mama
  • Ememe tsitretsitsi ƒe nɔnɔmewo
  • Dzoxɔxɔ ƒe mama
  • Charge, discharge, kple alarm ŋutinya
  • Beléle na nuŋlɔɖiwo

Le teƒe geɖe ƒe dɔwɔwɔ gome la, adzɔge yiyi kple nyatakaka siwo woxɔna le teƒe ɖeka ɖea ŋkuléle ɖe nu ŋu si mehiã o dzi kpɔtɔna eye wòkpena ɖe ƒuƒoƒowo ŋu be woatsɔ batri siwo hiã be woalé ŋku ɖe wo ŋu la aɖo nɔƒe gbãtɔ.

Batri dzikpɔkpɔ dashboard si ɖea voltage tsitretsitsi dzoxɔxɔ SOC SOH kple alarmwo fiana

6. Kpɔ Kadodo Kple Ðekawɔwɔ Dzi

Ele be ɖoɖoa nasɔ ɖe dɔwɔƒea ƒe ŋkuléleɖenuŋu ƒe nɔnɔme si li fifia nu ale be ɣlidodowo kple batri ŋuti nyatakakawo naɖo ƒuƒoƒo siwo hiã wo gbɔ.

Ðekawɔwɔ ƒe ɖoɖo siwo bɔ dometɔ aɖewoe nye:

  • Modbus ƒe RTU
  • Modbus TCP ƒe dɔwɔwɔ
  • SNMP ƒe dɔwɔwɔ
  • MQTT ƒe agbalẽ
  • IEC 61850 ƒe xexlẽdzesi

Ðewohĩ ahiã be nyatakakadzraɖoƒewo nawɔ ɖeka kple DCIM alo xɔwo dzikpɔkpɔ ƒe ɖoɖowo. Dɔwɔƒewo ateŋu abia be woawɔ SCADA, EMS, DCS, alo IEC 61850 ƒe ƒoƒo ɖekae. Telefonkadɔwɔƒewo ate ŋu atsɔ ɖoɖoa aƒo ka na NOC alo ŋusẽzazã ƒe mɔnu aɖe.

Bia protocol documentation kple data-point list hafi nàƒlee. Kpe ɖe eŋu nenye be ƒoƒo ɖekae bia be woawɔ agbo bubu, mɔɖegbalẽ, alo ŋgɔyiyi si wowɔ ɖe ɖoɖo nu.

7. Bu Eɖoɖo, Dedienɔnɔ, Kple Beléle Na Eŋu Ŋu

Dzro alesi sensorwo léna ɖe batriwo ŋu, alesi wowɔa adrɛs na mɔ̃woe, alesi woɖoa kawoe, kple nenye be woate ŋu awu dɔwɔwɔ nu evɔ womatso agba si wokpɔ ta na la me o.

Nyabiase veviwo dometɔ aɖewoe nye:

  • Ðe woate ŋu ade ɖoɖoa eme esime batri la gakpɔtɔ le dɔ wɔma?
  • Ðe wòdoa alɔ sensor ƒe adrɛsɖoɖo le eɖokui si kple kaƒoƒo-vodada didia?
  • Ðe woate ŋu aɖɔli sensor si do kpo nu evɔ womagbugbɔ network bliboa atu oa?
  • Hehe kple mɔ̃ɖaŋununya ƒe kpekpeɖeŋu kawoe li?

Le gota, ʋuɖoɖo, nuzazã, alo teƒe siwo afɔku le gome la, ɖo kpe nutome takpɔkpɔ si hiã, dzoxɔxɔ ƒe didime, dzo ƒe tsitretsitsi, xɔxlɔ̃ ƒe tsitretsitsi, kple elektrikŋusẽ ƒe sɔsɔ ɖe teƒe tɔxɛa hã dzi.

8. Se Vovototo si le ŋkuléle ɖe ame ŋu kple ŋutete dodokpɔ dome gɔme

Batria dzi kpɔkpɔ dea dzesi nɔnɔme siwo mesɔ o kple alesi wògblẽnae. Ŋutete dodokpɔ ɖoa ​​kpe ŋusẽ alo ɣeyiɣi didi si batri la ate ŋu ana le dodokpɔ ƒe nɔnɔme siwo woɖe fia me.

Voltage, temperature, current, kple ememe tsitretsitsi nye lãmesẽfianu veviwo, gake womeɖo kpe batri ƒe ka ƒe ampere-hour ŋutete si li dzi tẽ o. Eyata ele be dɔwɔƒe veviwo nabu beléle na dɔwɔƒea ƒe ɖoɖo si me woatsɔ ŋkuléle ɖe nu ŋu atraɖii kple ŋutete ƒe kpeɖodzinana tso ɣeyiɣi yi ɣeyiɣi aƒo ƒui ŋu.

Kpɔe ɖa be ŋkuléle ɖe nu ŋu kple ŋutete dodokpɔ ate ŋu ama nyatakakawo kple nyatakakawo hã. Mɔnu si wotsɔ wɔ ɖekae ate ŋu ana beléle na wo kple wo ɖɔliɖɔli ŋuti nyametsotsowo nanɔ bɔbɔe.

Tiatia ƒe Nu Veviwo Le Dɔwɔwɔ Nu

Nyatakakadzraɖoƒewo kple UPS Dɔwɔɖoɖowo

Tsɔ lãmenugbagbeviwo ƒe ɖoƒe dzi kpɔkpɔ, ememe tsitretsitsi ƒe nɔnɔme, dzoxɔxɔ ƒe ɣlidodo, SNMP alo DCIM ƒe ƒoƒo ɖekae, nyatakaka nana si ŋu kakaɖedzi le, kple batri siwo gbɔdzɔ ƒe dzesidede kabakaba ɖo nɔƒe gbãtɔ.

Ŋusẽdɔwɔƒewo Kple Dɔwɔƒe Suewo

Kpe asi ɖe kpekpeɖeŋu nana Ni-Cd, VRLA, alo batri siwo tsi yɔ, lãmenugbagbevi gãwo ƒe xexlẽme, charger kple insulation dzi kpɔkpɔ, nutoa me HMI ƒe nudidiwo, Modbus, kple IEC 61850 ƒe ƒoƒo ɖekae si woate ŋu atia dzi.

Telefon dzi kadodowo

Tsɔ 48V ɖoɖoa ƒe sɔsɔ, adzɔge ʋĩ ƒe ɣlidodo, nyatakakawo dzraɖoƒe si mele Internet dzi o, 4G alo Ethernet kadodo, beléle na nudidi siwo mebɔ o, kple teƒe geɖe dzikpɔkpɔ le teƒe ɖeka ɖo nɔƒe gbãtɔ.

Ami, Gas, Kple Dɔwɔƒe sesẽwo

Da nutome takpɔkpɔ, xɔxlɔ̃ ƒe tsitretsitsi, dzo ƒe dedienɔnɔ, sensor ƒe kakaɖedzi, adzɔge yiyi, kple ɖekawɔwɔ kple dɔwɔƒewo ƒe dziɖuɖu ƒe ɖoɖowo kpɔ.

Ʋuɖoɖo

Kpɔ ʋuʋudedi ƒe tsitretsitsi, teƒe si woma ƒe dzikpɔkpɔ, kpekpeɖeŋu nana ʋudzeƒe kple ʋu ƒe batri ƒe ɖoɖowo, kadodo si ŋu kakaɖedzi le, kple vodada ƒe teƒeteƒewo didi kabakaba.

Battery Monitoring System Tiatia ƒe Dzesidegbalẽvi

Dzra nyatakaka siwo gbɔna ɖo hafi nàbia be woaɖo aɖaŋu na ye:

  • Dɔwɔwɔ kple dɔwɔƒe
  • Batri ƒe atikeŋutinunya kple ewɔla
  • Nominal cell alo block ƒe elektrikŋusẽ
  • Lãmenugbagbeviwo kple kawo ƒe xexlẽme
  • Wobia tso ŋkuléle ɖe nu ŋu ƒe nɔnɔmewo
  • SCADA, DCIM, EMS, DCS, alo NOC ƒe mɔ̃ si li fifia
  • Kadodomɔnu siwo hiã
  • Xɔme, gota, alo nuto si me afɔku le
  • Nudidi siwo ku ɖe alarm nana ŋu
  • Dɔa ƒe ɖoɖowɔɖi kple kekeɖenudɔa ƒe ɖoɖo siwo woawɔ le etsɔme

Nukatae Nàtia DFUN Batria Dzi Kpɔkpɔ ƒe Egbɔkpɔnuwo?

DFUN naa batri dzi kpɔkpɔ, adzɔge ŋutete dodokpɔ, smart lithium-ion backup power, kple centralized management solutions na ŋusẽdɔ veviwo. Ðoɖo siwo li doa alɔ cell- kple string-level ŋkuléle ɖe nu ŋu, ŋutinya me nɔnɔmewo me dzodzro, nunya ƒe ɣlidodowo, adzɔge dzikpɔkpɔ, kple ɖekawɔwɔ kple dɔwɔƒewo ƒe ɖoɖo siwo bɔ.

DFUN ƒe ɖoɖo si sɔ nɔ te ɖe batri ƒe atikewɔwɔ, teƒea ƒe lolome, ŋkuléleɖenuŋu ƒe nudidiwo, kple kadodo ƒe xɔtuɖaŋu dzi. Dɔa ŋuti nyatakaka siwo de pɛpɛpɛ nana ɖea mɔ na mɔ̃ɖaŋudɔwɔlawo ƒe ƒuƒoƒoa be woakafu sensor, controller, agbo, kple kɔmpiutadziɖoɖo siwo sɔ.

Nya Siwo Wobia Enuenu

Nukae nye nu vevitɔ kekeake si le batri ƒe ŋkuléleɖenuŋu ƒe mɔ̃ ŋu?

Nu vevitɔ kekeake nɔ te ɖe dɔwɔnua dzi, gake lãmenugbagbeviwo ƒe dzedzeme, nɔnɔme ŋuti nyatakaka siwo ŋu kakaɖedzi le, kple ɣlidodo siwo woate ŋu awɔ dɔ le nye nu vevi siwo woatsɔ ade dzesi batri siwo gbɔdzɔ hafi woakpɔ ŋusẽ ɖe ka bliboa dzi.

Ðe ka ƒe ʋuʋudedi dzi kpɔkpɔ sɔ gbɔa?

Ao, ka ƒe elektrikŋusẽ si sɔ ate ŋu aɣla lãmenugbagbevi alo mɔxenu ɖekaɖeka si mesɔ o. Cell-level voltage, ememe tsitretsitsi, kple dzoxɔxɔ dzi kpɔkpɔ naa woate ŋu ade dzesi vodadawo do ŋgɔ eye wòdea pɛpɛpɛ wu.

Ðe ɖoɖo ɖeka ate ŋu alé ŋku ɖe batri ƒe atike vovovowo ŋua?

Dɔnyala aɖewo ƒe mɔ̃wo doa alɔ VRLA, Ni-Cd, tsiɖɔɖɔ ƒe lead-acid, kple lithium batri zazã. Ele be woaɖo kpe ɖekawɔwɔ dzi na lãmenugbagbevi ƒe ʋuʋudedi tɔxɛ, ka ƒe ɖoɖo, kple nɔnɔmetata siwo hiã.

Ðe mɔ̃ aɖe si léa ŋku ɖe batri ŋu dzidzea batri ƒe ŋusẽ ŋutɔŋutɔa?

Kpɔkpɔ bua batri ƒe nɔnɔme tso dɔwɔwɔ ƒe nɔnɔmewo kple nɔnɔmewo me. Ele be woaɖo kpe ŋutete ŋutɔŋutɔ si li alo ɣeyiɣi si woatsɔ awɔ dɔe dzi to batri ƒe ŋutete dodokpɔ si sɔ me.

Ðe batri dzi kpɔkpɔ ƒe ɖoɖo aɖe ate ŋu awɔ ɖeka kple SCADA alo DCIM?

Ẽ, ne edo alɔ ɖoɖowɔɖi kple nyatakaka teƒe siwo wobia. Tiatia siwo bɔ dometɔ aɖewoe nye Modbus, SNMP, MQTT, kple IEC 61850. Ele be woaɖo kpe ɖekawɔwɔ ƒe nudidiwo dzi le ɖoɖoa ƒe ɖoɖowɔwɔ me.

Ðe woate ŋu akeke ɖoɖoa ɖe enu emegbea?

Dɔwɔɖoɖo si woate ŋu atrɔ asi le ate ŋu atsɔ batri ƒe ka, nyatakakadzraɖoƒe, agbo, alo kɔmpiutadziɖoɖo ƒe mɔɖegbalẽwo akpe ɖe eŋu ne dɔa le dzidzim ɖe edzi. Ðo kpe kekeɖenudɔ ƒe seɖoƒewo kple xɔtuɖaŋu dzi hafi nàƒlee.

Bia Batria Dzi Kpɔkpɔ ƒe Dɔwɔɖoɖo ƒe Aɖaŋuɖoɖo

Batria dzi kpɔkpɔ ƒe ɖoɖo nyuitɔ tiatia dzea egɔme tso dɔwɔwɔ, batri ƒe ɖoɖowɔwɔ, afɔku ƒe seƒe, kple ƒoƒo ɖekae ƒe nudidiwo dzi. Ðo wò batri ƒe ƒomevi, elektrikŋusẽ, agbɔsɔsɔme, ka ƒe xexlẽme, kadodomɔnu, kple ŋkuléleɖenuŋu ƒe nɔnɔme siwo hiã la ɖe DFUN. Míaƒe mɔ̃ɖaŋudɔwɔlawo ƒe ƒuƒoƒoa akpe ɖe ŋuwò nàto egbɔkpɔnu aɖe vɛ na wò ŋusẽ ƒe ɖoɖo vevi la.

Na Batriki ƒe Dzesidede Femaxee

Míaƒe BMS mɔ̃ɖaŋudɔwɔlawo dometɔ ɖeka aɖo eŋu le gaƒoƒo 24 me.

(Ne èdi. Na mɔ̃ɖaŋunya siwo hiã kpata ko)

Míedea bubu wò nyatakakawo ŋu. Woazã wò nyatakakawo atsɔ aɖo wò biabiaa ŋu ko.

Do Ka Kple Mía

Adzɔnuwo ƒe Ƒomedodo

Kadodo Kabakabawo

Te Ðe Mía Ŋu

   +86- 15919182362 xexlẽdzesi
  +86-756-6123188 dzi

Nutata ƒe Gomenɔamesi © 2023 DFUN (ZHUHAI) CO., LTD. Gomenɔamesiwo katã le esi. Ameŋunyatakakawo Ŋuti Ðoɖo | Nyatakakadzraɖoƒe ƒe Nɔnɔmetata