Yuav ua li cas xaiv lub roj teeb saib xyuas kev siv hluav taws xob tseem ceeb

Nug

facebook share khawm
twitter sib koom khawm
kab sib koom khawm
wechat sib koom khawm
linkedin sib koom khawm
pinterest sib koom khawm
whatsapp share khawm
share this share khawm

Lub roj teeb saib xyuas txoj cai yuav tsum phim cov roj teeb chemistry, qhov system voltage, qhov chaw ib puag ncig, kev saib xyuas lub tswv yim, kev sib txuas lus architecture, thiab kev ntseeg siab ntawm daim ntawv thov.

Rau cov chaw zov me nyuam, substations, telecom sites, tsheb thauj mus los, thiab cov chaw tsim khoom, lub roj teeb uas tsim nyog rau kev siv hluav taws xob tseem ceeb pab cov neeg ua haujlwm txheeb xyuas cov hlwb tsis muaj zog, qhov kub tsis zoo, teeb meem kev sib txuas, thiab cov teeb meem them nyiaj ua ntej yuav tsum muaj lub zog thaub qab. Phau ntawv qhia no piav qhia txog cov kev xaiv tseem ceeb tshaj plaws.

Roj teeb saib xyuas qhov system rau cov chaw zov me nyuam cov chaw thiab cov chaw sib tham

Pib nrog qhov Risk Koj Yuav Tsum Tau Tswj

Cov chaw sib txawv ntsib teeb meem roj teeb sib txawv. Ib lub chaw cov ntaub ntawv tuaj yeem ua qhov tseem ceeb ntawm UPS muaj thiab kev koom ua ke nrog DCIM. Lub chaw siv hluav taws xob yuav xav tau Ni-Cd kev txhawb nqa thiab kev sib txuas lus nrog SCADA. Tus neeg siv xov tooj tuaj yeem xav tau lub tswb nyob deb thiab cov ntaub ntawv hauv zos khaws cia rau qhov chaw tsis muaj neeg saib. Cov chaw siv roj thiab roj yuav xav tau cov cuab yeej tsim los rau qhov hnyav lossis corrosive ib puag ncig.

Ua ntej sib piv cov khoom, txhais cov txiaj ntsig ntawm lub roj teeb tsis ua haujlwm:

  • Qhov kev thauj khoom tseem ceeb npaum li cas, thiab lub sijhawm ua haujlwm ntev npaum li cas tuaj yeem ua tau?
  • Puas yog cov roj teeb tau teeb tsa ntawm ib qho chaw lossis hla ntau qhov chaw nyob deb?
  • Cov kev ua tsis tau zoo twg yuav tsum raug kuaj pom ua ntej kev tso tawm thaum muaj xwm txheej ceev?
  • Leej twg tau txais lub tswb, thiab lawv yuav tsum teb sai npaum li cas?

Cov lus teb txiav txim siab seb qhov project xav tau kev saib xyuas cov hlua-theem lossis cov xov tooj ntawm tes-theem roj teeb saib xyuas qhov system nrog lub tswb ceeb toom thiab kev tswj hwm hauv nruab nrab.

1. Xaiv Cell-Level Monitoring rau Early Fault Detection

Ib txoj hlua roj teeb tsuas yog txhim khu kev qha raws li nws qhov tsis muaj zog ntawm tes lossis thaiv. Txoj hlua hluav taws xob tuaj yeem tshwm sim ib txwm muaj txawm tias thaum ib tus neeg lub roj teeb muaj qhov ua haujlwm siab sab hauv, qhov kub tsis zoo, lossis txo qhov muaj peev xwm tawm.

Cell-theem saib xyuas muab kev saib xyuas pab pawg pom hauv txhua lub roj teeb. Kev ntsuas tseem ceeb yuav suav nrog:

  • Tus kheej ntawm tes los yog thaiv voltage
  • Internal kuj los yog impedance sib
  • Roj teeb davhlau ya nyob twg kub
  • Txoj hlua voltage
  • Charge thiab tawm tam sim no
  • Float thiab ripple tam sim no
  • SOC thiab SOH
  • Ambient kub thiab av noo

Nug seb qhov ntsuas tau npaum li cas, seb cov ntawv nyeem tau khaws cia raws li cov qauv, thiab seb lub platform puas sib piv txhua lub roj teeb nrog nws cov hauv paus ntsiab lus thiab lwm txoj hlua.

Lub roj teeb tsis muaj zog tau kuaj pom los ntawm qhov ntsuas kub ntawm tes thiab kev saib xyuas sab hauv

2. Paub meej tias roj teeb Chemistry thiab System Compatibility

Lub kaw lus xaiv yuav tsum txhawb nqa cov roj teeb chemistry, nominal voltage, txoj hlua teeb tsa, thiab cov xov tooj ntawm cov tshuaj xyuas.

VRLA roj teeb

Rau 2V, 6V, thiab 12V VRLA roj teeb, qhov hluav taws xob, kev tiv thaiv sab hauv, kub, tam sim no, thiab kev tsom xam mus sij hawm ntev yog qhov tseem ceeb. Kev nce hauv kev tiv thaiv los yog nce qhov sib txawv ntawm qhov kub thiab txias yuav ua rau muaj kev ceeb toom ntxov ntawm kev tsis zoo, tab sis cov ntsuas no yuav tsum tau soj ntsuam ua ke es tsis yog siv los ua cov txheej txheem hloov pauv.

Ni-Cd roj teeb

Ni-Cd roj teeb lub tsev txhab nyiaj muaj nyob rau hauv substations, fais fab nroj tsuag, rail systems, thiab industrial DC systems. Paub meej tias cov cuab yeej saib xyuas txhawb nqa 1.2V hlwb thiab tag nrho cov xov tooj ntawm txhua txoj hlua. Voltage tshuav nyiaj li cas, qhov kub thiab txias, kev coj tus cwj pwm, thiab cov qauv mus sij hawm ntev yog qhov tshwj xeeb tshaj yog rau cov tshuaj no.

Flooded Lead-Acid Batteries

Cov roj teeb dej nyab tej zaum yuav xav tau kev ua haujlwm ntxiv xws li qib electrolyte, xau, thiab kev saib xyuas kev sib txuas. Xyuas kom tseeb tias cov sensors no tuaj yeem muab tso rau hauv tib lub chaw tswj hwm.

Lithium-ion roj teeb

Rau cov tshuab lithium, qhia meej seb qhov project yuav tsum muaj txheej txheem saib xyuas kev ywj pheej, kev sib txuas lus nrog lub roj teeb pob BMS, lossis kev tswj hwm hauv nruab nrab ntawm ntau lub roj teeb hom thiab qhov chaw.

3. Ntsuas qhov ua tiav System Architecture

(Data Center raws li kev siv)

Ib qho kev daws teeb meem ib txwm suav nrog cov xov tooj ntawm tes, cov cuab yeej ntsuas txoj hlua, tus tswj lossis lub rooj vag, kev sib txuas lus sib txuas, thiab kev tswj hwm software.

Thaum rov xyuas cov architecture, kos:

  • Cov kab mob siab tshaj plaws thiab cov hlua txhawb nqa ib tus maub los
  • Txoj kev nthuav dav rau yav tom ntej ntxiv roj teeb
  • Lub peev xwm khaws cia hauv zos thaum muaj kev cuam tshuam hauv lub network
  • Cov ntaub ntawv synchronization tom qab lub network rov qab los
  • Compatibility nrog kev faib thiab ntau qhov chaw ua haujlwm
Roj teeb xyuas system architecture nrog cell sensors controller gateway and software platform (Data center as reference)

4. Txheeb xyuas lub tswb zoo, tsis yog lub tswb kom muaj nuj nqis xwb

Lub platform saib xyuas yuav tsum hloov kev ntsuas rau hauv cov ntaub ntawv ua tau. Ntau lub tswb ntau dhau ua rau lub tswb qaug zog, thaum ib qho chaw ruaj khov tuaj yeem ploj zuj zus zuj zus.

Nrhiav cov haujlwm xws li:

  • Kev ceeb toom, tswb, thiab qib tseem ceeb
  • Configurable thresholds los ntawm hom roj teeb thiab qhov chaw
  • Trend-based alarms thiab ntsuas tus nqi hloov pauv
  • Tswb qeeb thiab rov qab logic
  • Kev txheeb xyuas qhov tseeb ntawm qhov chaw, hlua, thiab roj teeb
  • Email, SMS, platform, thiab kev xaiv tswb hauv zos
  • Alarm keeb kwm thiab kev lees paub

Lub tswb zoo tshaj plaws tsis yog ib qho lus uas tus nqi tshaj qhov txwv. Nws yuav tsum qhia tus neeg teb xov tooj qhov teeb meem, nws loj npaum li cas, thiab cov ntaub ntawv twg tau hloov.

5. Tshawb xyuas kev tshaj tawm thiab kev kwv yees ua haujlwm tu

Vim tias lub roj teeb degradation feem ntau yog maj mam, lub platform yuav tsum sib piv cov kev nyeem tam sim no nrog cov hauv paus hauv paus, lub sijhawm dhau los, thiab lwm lub hlwb hauv tib txoj hlua.

Cov ntawv ceeb toom tseem ceeb suav nrog:

  • Roj teeb saib xyuas kev noj qab haus huv
  • Cell voltage faib
  • Internal resistance trends
  • Kev faib tawm kub
  • Charge, tso tawm, thiab lub tswb keeb kwm
  • Cov ntaub ntawv kho mob

Rau ntau qhov chaw ua haujlwm, kev nkag mus rau cov chaw taws teeb thiab cov ntaub ntawv hauv nruab nrab txo qis kev tshuaj xyuas tsis tsim nyog thiab pab pawg saib xyuas cov roj teeb tseem ceeb uas xav tau kev saib xyuas.

Roj teeb saib xyuas dashboard displaying voltage kuj kub SOC SOH thiab tswb

6. Tshawb xyuas kev sib txuas lus thiab kev koom ua ke

Lub kaw lus yuav tsum haum rau hauv qhov chaw saib xyuas qhov chaw uas twb muaj lawm kom lub tswb thiab cov ntaub ntawv roj teeb mus txog cov pab pawg uas xav tau.

Common integration protocols muaj xws li:

  • Modbus RTU
  • Modbus TCP
  • SNMP
  • MQTT
  • IEC 61850: Ua

Cov chaw zov me nyuam tej zaum yuav xav tau kev koom ua ke nrog DCIM lossis lub tsev tswj kev tswj hwm. Cov khoom siv hluav taws xob yuav xav tau SCADA, EMS, DCS, lossis IEC 61850 kev koom ua ke. Cov tswv lag luam hauv xov tooj tuaj yeem txuas cov kab ke mus rau NOC lossis lub zog tswj hwm lub platform.

Nug rau cov ntaub ntawv raws tu qauv thiab cov ntaub ntawv teev npe ua ntej yuav khoom. Paub meej tias kev sib koom ua ke yuav tsum muaj qhov rooj ntxiv, daim ntawv tso cai, lossis kev tsim kho.

7. Xav txog kev txhim kho, kev nyab xeeb, thiab kev tu

Tshawb xyuas seb cov sensors txuas rau cov roj teeb li cas, cov cuab yeej siv li cas, yuav ua li cas cables raug xa mus, thiab seb kev ua haujlwm puas tuaj yeem ua tiav yam tsis muaj kev cuam tshuam cov khoom tiv thaiv.

Cov lus nug tseem ceeb suav nrog:

  • Lub kaw lus puas tuaj yeem ntsia tau thaum lub roj teeb tseem nyob hauv kev pabcuam?
  • Nws puas txhawb nqa tsis siv neeg sensor chaw nyob thiab xov tooj-yuam kev kuaj pom?
  • Puas tuaj yeem hloov pauv tsis tau lub sensor tsis tau rov tsim kho tag nrho lub network?
  • Muaj kev cob qhia thiab kev txhawb nqa dab tsi?

Rau sab nraum zoov, kev thauj mus los, kev siv hluav taws xob, lossis qhov chaw muaj kev phom sij, kuj lees paub qhov yuav tsum tau muaj kev tiv thaiv ib puag ncig, qhov kub thiab txias, tiv thaiv hluav taws, tiv thaiv corrosion, thiab electromagnetic compatibility rau qhov tshwj xeeb installation.

8. Nkag siab qhov sib txawv ntawm kev soj ntsuam thiab kev ntsuas kev muaj peev xwm

Kev tshuaj xyuas roj teeb pom cov xwm txheej txawv txav thiab cov qauv kev degradation. Kev ntsuas muaj peev xwm txheeb xyuas seb lub zog ntau npaum li cas lossis lub sijhawm ua haujlwm thaub qab lub roj teeb tuaj yeem xa tuaj raws li kev ntsuas ntsuas.

Qhov hluav taws xob, qhov kub thiab txias, tam sim no, thiab kev tiv thaiv sab hauv yog qhov tseem ceeb ntawm kev noj qab haus huv, tab sis lawv tsis ncaj qha ua pov thawj muaj peev xwm ampere-teev ntawm lub roj teeb. Cov chaw tseem ceeb yog li ntawd yuav tsum xav txog kev saib xyuas lub tswv yim uas ua ke nrog kev saib xyuas tas li nrog kev txheeb xyuas qhov muaj peev xwm ua ntu zus.

Txiav txim siab seb qhov kev soj ntsuam thiab kev ntsuas muaj peev xwm puas tuaj yeem qhia cov ntaub ntawv thiab cov ntawv ceeb toom. Ib qho kev sib xyaw ua ke tuaj yeem ua kom yooj yim txij nkawm thiab hloov kev txiav txim siab.

Xaiv qhov tseem ceeb los ntawm Daim Ntawv Thov

Data Centers thiab UPS Systems

Ua ntej ntawm kev saib xyuas ntawm tes, qhov kev tiv thaiv sab hauv, lub tswb ntsuas kub, SNMP lossis DCIM kev koom ua ke, kev tshaj tawm txhim khu kev qha, thiab kev txheeb xyuas sai ntawm cov roj teeb tsis muaj zog.

Fais fab kev pab cuam thiab substations

Paub meej tias kev txhawb nqa rau Ni-Cd, VRLA, lossis cov roj teeb dej nyab, cov xov tooj ntawm tes loj, kev saib xyuas lub charger thiab rwb thaiv tsev, cov kev cai HMI hauv zos, Modbus, thiab kev xaiv IEC 61850 kev koom ua ke.

Kev sib txuas lus

Ua ntej 48V kev sib raug zoo, lub tswb nyob deb, offline cov ntaub ntawv khaws cia, 4G lossis Ethernet kev sib txuas lus, kev saib xyuas tsis zoo, thiab kev tswj hwm ntau qhov chaw.

Roj, Roj, thiab Kev Lag Luam hnyav

Ntsuam xyuas kev tiv thaiv ib puag ncig, kev tiv thaiv corrosion, kev nyab xeeb hluav taws, kev ntseeg siab ntawm lub sensor, kev nkag mus rau tej thaj chaw deb, thiab kev koom ua ke nrog kev tswj hwm kev lag luam.

Kev thauj mus los

Tshawb xyuas kev vibration resistance, faib-site tswj, kev txhawb nqa rau chaw nres tsheb thiab lub tsheb roj teeb, kev sib txuas lus txhim khu kev qha, thiab kev ua txhaum sai sai.

Roj Teeb Saib Xyuas Qhov Kev Xaiv Cov Ntawv Tshawb Xyuas

Npaj cov ntaub ntawv hauv qab no ua ntej thov qhov kev thov:

  • Daim ntawv thov thiab kev lag luam
  • Roj teeb chemistry thiab chaw tsim tshuaj paus
  • Nominal cell los yog block voltage
  • Tus naj npawb ntawm cov hlwb thiab cov hlua
  • Yuav tsum tau saib xyuas qhov ntsuas
  • Tam sim no SCADA, DCIM, EMS, DCS, lossis NOC platform
  • Yuav tsum muaj kev sib txuas lus raws tu qauv
  • Sab hauv tsev, sab nraum zoov, lossis ib puag ncig txaus ntshai
  • Cov cai ceeb toom ceeb toom
  • Cov phiaj xwm phiaj xwm thiab cov phiaj xwm nthuav dav yav tom ntej

Vim li cas thiaj xaiv DFUN Battery Monitoring Solutions?

DFUN muab kev saib xyuas roj teeb, kev ntsuas kev muaj peev xwm nyob deb, ntse lithium-ion thaub qab lub zog, thiab kev tswj hwm hauv nruab nrab rau kev siv hluav taws xob tseem ceeb. Muaj cov kev teeb tsa txhawb nqa ntawm tes- thiab txoj hlua-theem saib xyuas, kev txheeb xyuas keeb kwm yav dhau los, lub tswb nrov, kev tswj chaw taws teeb, thiab kev koom ua ke nrog cov txheej txheem kev lag luam.

Qhov tsim nyog DFUN configuration nyob ntawm lub roj teeb chemistry, qhov chaw teev, saib xyuas cov cai, thiab kev sib txuas lus architecture. Muab cov ntaub ntawv qhia txog qhov tseeb tso cai rau pab pawg ua haujlwm kom pom zoo cov sensors, controllers, gateways, thiab software.

Cov lus nug nquag nug

Dab tsi yog qhov tseem ceeb tshaj plaws ntawm lub roj teeb saib xyuas qhov system?

Qhov tseem ceeb tshaj plaws yog nyob ntawm daim ntawv thov, tab sis kev pom ntawm tes-qib, cov ntaub ntawv txhim khu kev qha, thiab lub tswb nrov yog qhov tseem ceeb rau kev kuaj xyuas cov roj teeb tsis muaj zog ua ntej lawv cuam tshuam rau txoj hlua tiav.

Puas yog txoj hlua hluav taws xob saib xyuas txaus?

Tsis yog. Ib txoj hlua ib txwm muaj peev xwm zais ib tus neeg lub xov tooj ntawm tes lossis thaiv. Cell-theem voltage, kev tiv thaiv sab hauv, thiab kev ntsuas qhov kub thiab txias muab kev txheeb xyuas ua ntej thiab meej dua.

Ib lub cev puas tuaj yeem saib xyuas cov roj teeb sib txawv?

Qee qhov kev tshaj lij platform txhawb VRLA, Ni-Cd, dej nyab cov kua qaub, thiab lithium roj teeb daim ntawv thov. Kev sib raug zoo yuav tsum tau lees paub rau qhov tshwj xeeb ntawm tes hluav taws xob, txoj hlua teeb tsa, thiab qhov yuav tsum tau ua.

Puas yog lub roj teeb saib xyuas qhov ntsuas ntsuas lub roj teeb tiag tiag?

Kev soj ntsuam kwv yees cov teeb meem roj teeb los ntawm kev khiav hauj lwm tsis ua haujlwm thiab cov qauv. Muaj peev xwm muaj peev xwm lossis lub sijhawm ua haujlwm yuav tsum raug txheeb xyuas los ntawm kev ntsuas lub roj teeb uas tsim nyog.

Lub roj teeb saib xyuas lub cev puas tuaj yeem koom nrog SCADA lossis DCIM?

Yog lawm, yog tias nws txhawb nqa cov txheej txheem thiab cov ntaub ntawv xav tau. Cov kev xaiv muaj xws li Modbus, SNMP, MQTT, thiab IEC 61850. Kev sib koom ua ke yuav tsum tau lees paub thaum lub sijhawm tsim qauv.

Lub kaw lus puas tuaj yeem nthuav dav tom qab?

Lub kaw lus scalable tuaj yeem ntxiv cov hlua roj teeb, qhov chaw, rooj vag, lossis cov ntawv tso cai software raws li qhov project loj tuaj. Paub meej txog kev txwv kev nthuav dav thiab kev tsim vaj tsev ua ntej yuav khoom.

Thov ib daim ntawv thov roj teeb saib xyuas qhov system

Xaiv lub roj teeb saib xyuas txoj cai pib nrog daim ntawv thov, kev teeb tsa roj teeb, theem kev pheej hmoo, thiab cov kev xav tau ntawm kev sib koom ua ke. Xa DFUN koj lub roj teeb hom, qhov voltage, kom muaj nuj nqis, tus lej ntawm cov hlua, txoj kev sib txuas lus, thiab qhov yuav tsum tau soj ntsuam xyuas. Peb pab neeg ua haujlwm engineering yuav pab koj tsim kev daws teeb meem rau koj lub zog tseem ceeb.

Tau txais kev ntsuam xyuas roj teeb dawb

Ib tug ntawm peb BMS engineers yuav teb tsis pub dhau 24 teev.

(Yeem xaiv tau. Tsuas yog rau cov teeb meem ceev ceev)

Peb hwm koj tus kheej. Koj cov ntaub ntawv tsuas yog siv los teb rau koj qhov kev thov.

Txuas Nrog Peb

Yam khoom

Txuas ceev

Tiv tauj peb

   + 15919182362
  +86-756-6123188
  + 15919182362

Copyright © 2023 DFUN (ZHUHAI) CO., LTD. Txhua txoj cai. Txoj Cai Tswjfwm Ntiag Tug | Daim duab qhia chaw