A ziaktu: Site Editor Thuchhuah Hun: 2023-07-06 A chhuahna hmun: Hmun
Uninterruptible power supply (UPS) chu electrical device a ni a, power outage emaw voltage inthlak danglam emaw laiin hmanraw pawimawh tak tak emaw system emaw-ah emergency backup power a pe thei a ni. Power protection device angin a thawk a, hei hian utility power hloh leh backup power sources activation inkar gap a bridge a, connected devices te chu tihtawp lohvin a thawk thei a ni. A pawimawh ber chu UPS system hian power hloh atanga 25ms chhunga backup power activate thei tur a ni. Chutiang a nih loh chuan i data center emaw telecom station emaw chuan power failer a nih chuan out of service a tuar ang.
UPS hian data hloh, outage, leh hardware chhiatna man to tak tak (voltage anomalies smoothing out) laka invenna pawimawh tak a pe a ni. Telecome station leh data center ang chi scenario-ah chuan UPS-a battery te chu darkar engemaw zat emaw a aia rei emaw chhung a awm thei. Commercial power failure hi a tlem ber leh tawi tea ngaih a nih a rinawm ber a nih chuan UPS hi remote site-a key backup power source a ni ang.
Hetiang dinhmunah hian UPS humhalh hi hna pawimawh tak a ni bawk. Chuvangin UPS chungchanga thudik tam zawk, leh UPS enkawlna atana hmanraw changkang tak tak leh thil pawimawh tak tak thenkhat i chhui ang u.
1. Kut hmanga enfiah leh enkawl dan:
Visual inspection leh kut hmanga enkawl fo thin a ni. Manual inspection hian UPS battery enkawlna kawngah hmun pawimawh tak a chang a ni. Hei hian battery-te chu taksa chhiatna, leak, emaw, corrosion emaw a awm leh awm loh hriat theiha enfiah a huam a ni. Battery connection check te, a fai leh a him leh him loh enfiah te pawh a huam tel bawk. Manual maintenance hnaah chuan terminal tihfai te, connection tihkhauh te, battery voltage inthlauhna te, battery siamtuin a rawt preventive maintenance procedure te tih te a tel thei. Routine inspection leh maintenance neih a nih chuan thil awm thei te chu a hmain hriat theih a ni a, battery te chu a thawk tha hle tih a chiang thei a ni.
2. Battery hmanga test neih fo thin: 1.1.
A hun hunah battery capacity testing neih thin hi UPS battery enkawlna atana hmanraw tangkai dang a ni bawk. Hei hian battery-a load test tih a huam a, chu chu an theihna leh power pek theihna, simulated operating conditions hnuaia power pek theihna a ni. Capacity testing hian routine monitoring chauh hmanga hmuh theih loh tur battery chak lo emaw, hlawhchham emaw hriat theihna a pui a ni. Battery-te theihna tak tak tehna hmang chuan an service life la awm chu dik taka sawi lawk theih a ni a, a hun taka thlakna tur ruahmanna siam theih a ni ta a ni.
3. Battery enkawl dan tur (BMS) inzawmkhawm:
Battery Management System (BMS) leh UPS battery te inzawmkhawm hian battery parameter te chu enfiah leh enkawl chhunzawm theih a ni. BMS hian battery hriselna, voltage level, temperature leh metric pawimawh dangte chungchangah real-time data a pe a ni. Battery chu a dam chhung tawp a hnaih tawh a, nungchang pangngai lo a tawk a, enkawl a ngai a nih chuan alert leh notification a thawn thei bawk. BMS hian battery performance chungchang hriatna a pe a, proactive measures te chu thil awm thei te hmachhawn thei tur leh battery life tihchangtlunna tur a ni.
5 .Last but not least: Battery Moniroring chungchang hi zir belh zel rawh
Battery monitoring techniques a lo thang chho zel a, hei hi UPS systems enkawl dan dik tak enfiah a nih theih nan highly dependable network dinna atana thil pawimawh tak a ni. I battery string venhim loha dah chu i lei theih tur option a ni lo mai mai. Level engemaw zat monitoring neih chu hmasawnna a nih laiin, monitoring system remchang thlan hian overall outcomes nasa takin a nghawng thei a ni. UPS system enkawlna tha tak chungchanga insights dang i duh emaw, i network nena inmil monitoring solution design chungchangah keimah emaw kan team member pakhat emaw nena inrawn i duh chuan vawiin hian min rawn pan hreh suh ang che.
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .