Battery string chu cell emaw block emaw a chhe tan lai pawhin a pangngai angin a lang thei. Hei hi inthlauhna bulpui ber a ni cell-level battery monitoring leh string-level battery monitoring : pakhat hian battery tinte dinhmun a tarlang a, pakhat zawk chuan string kimchang tak takte awm dan inzawmkhawm a entir thung.

Monitoring level pahnih hian thu angkai tak tak a pe a, mahse maintenance zawhna hrang hrang an chhang thung. He kaihhruaina hian approach tin hian eng nge a teh tih te, eng fault nge a lantir theih tih te, UPS system, substation, telecom site, transportation network, leh industrial critical power application te tana monitoring architecture dik tak thlan dan tur a sawifiah a ni.

DFUN cell-level battery enfiahna system a ni
DFUN cell-level battery enfiahna system a ni

String-Level Battery Monitoring hi eng nge ni?

String-level battery monitoring hian series-a inzawm battery string kimchang tak electrical behavior a teh a ni. System design a zirin hetiang hian a monitor thei:

  • String voltage zawng zawng
  • Charge leh discharge current a awm
  • Float current a ni
  • Ripple current leh ripple voltage te a awm bawk
  • Ambient temperature leh humidity a awm lo
  • Insulation emaw leakage emaw awm dan tur
  • Discharge hun chhung leh string-level thil thleng te

He information hian operator te chu charger leh battery string te chu beisei angin a thawk em tih hriat nan a pui thin. Total voltage pangngai lo, beisei loh discharge, current tam lutuk, charger problem, emaw, parallel string nena current insem dik lo string emaw ang chi condition te a hriat theih a ni.

Mahse, string-level monitoring hian a tlangpuiin eng battery pakhatin nge inthlak danglamna a thlen tih a hre lo. Technician chuan string hian harsatna a nei tih a hria a, mahse a nghawng cell emaw block emaw awmna tur chu kut hmanga teh a la ngai tho.

Cell-Level Battery Monitoring hi eng nge ni?

Cell-level battery monitoring hian cell emaw battery block tin tan sensor pakhat emaw measurement channel emaw a hmang thin. Battery chemistry leh solution thlan dan azirin system hian hetiang hian a record thei:

  • Cell pakhat zel emaw block voltage emaw a awm thei
  • Internal resistance emaw impedance emaw a awm thei
  • Battery terminal temperature a ni
  • Connection emaw intercell emaw atanga invenna
  • Tui lian battery supported te tan electrolyte level
  • Leakage awm dan tur
  • Historic trends leh string chhunga battery dang atanga inthlak danglamna

String kimchang value pakhat chauh lantir ai chuan cell-level battery monitoring system chuan battery tinte awm dan a entir a ni. Hei hian cell chak lo, temperature danglam, resistance sang, voltage imbalance, connection problem emaw chu string level-a a lan hmain hriat a awlsam phah a ni.

DFUN cell-level battery sensor pakhat zel stationary battery-ah dah a ni
DFUN cell-level battery sensor pakhat zel stationary battery-a dah a ni

Engvangin nge Normal String Voltage hian Battery chak lo tak a thup theih

Series-connected battery string-ah chuan voltage zawng zawng chu battery voltage pakhat zel zawng zawng zatve a ni. Battery pakhatin voltage pangngai lo a neih chuan battery dang leh charger chuan hun eng emaw chen chu an compensate thei a, string voltage zawng zawng chu pawm theih anga lang range chhungah a awm thei a ni.

Entirnan, charger hian beisei angin overall float voltage a vawng reng thei a, block hrang hrangte chu voltage hrang hrangah an thawk thei bawk. Battery pakhat chu undercharged a nih laiin pakhat chu float voltage sang zawkah a awm thei bawk. String reading kimchang chauh hian he distribution hi a lantir lo.

Discharge lai pawhin chutiang limitation chu a pawimawh zual hle. Battery chak lo ber chuan string dang zawng aiin a low-voltage condition a thleng hma thei a, battery bank pumpui hman theih performance a tikhawtlai a, battery pangngai chu a la hrisel hmel hle.

Mimal battery chak lo tak chu normal total string voltage-in a thup
Mimal battery chak lo tak chu normal total string voltage-in a thup

Cell-Level leh String-Level Battery enfiahna a ni

Measurement Resolution siam a ni

String-level monitoring hian string kimchang chu combined view pakhat a pe a. Cell-level monitoring hian monitored cell emaw block emaw zawng zawng chu a hranin a hmu thei a ni.

Fault hriatchhuah theihna

String-level monitoring hian voltage zawng zawng, current, discharge, charging, leh environment-a thil dik lo awmte chu a hmu thei a ni. Cell-level monitoring hian battery hrang hrang inkara danglamna a pholang thei bawk a, chung zingah chuan voltage deviation, resistance tihpun, leh localized temperature rise te pawh a tel.

Fault awmna hmun

String-level alarm hian chhui chian belh a ngai tih a tarlang. Cell-level alarm hian a nghawngna hmun, string leh battery awmna hmun a hre thei a, chu chuan maintenance team-te chu harsatna chu rang zawka hriat theih nan a pui thei a ni.

Historic thlirletna (Historical Analysis) a ni

String trends hian battery bank kimchang chu hun kal zelah engtin nge a awm tih a tarlang. Cell-level trends hmang hian operator-te chuan battery pakhat chu a baseline nen leh string khata a kianga battery awmte nen an khaikhin thei a ni.

Installation leh Data mamawh te

String-level system-ah chuan measurement point tlem zawk, wiring tlem zawk leh data dahkhawm tlem zawk a ngai tlangpui. Cell-level system hian sensor dang, installation hna, addressing, communication, leh data management te a mamawh a, mahse diagnostic information chipchiar zawk a pe thung.

A hmanraw tha ber ber

String-level monitoring hi basic supervision emaw lower-risk installation emaw atan a tha thei. Cell-level monitoring hi battery pakhat a chhiat chuan service chhunzawm zelna, himna emaw, emergency response emaw a nghawng theihna hmun, critical emaw remote application-ah a tha zawk.

Monitoring Level Tinte hian Eng Harsatna Nge A Hmuh Theih?

String Level-a Harsatna hmuh theih

  • String voltage zawng zawng a pangngai lo
  • Beisei loh charging emaw discharge emaw current a awm
  • Battery string kimchang pakhat hloh
  • Parallel string inkara current insem dan inang lo
  • Ripple current emaw voltage emaw a tam lutuk
  • Room lum leh vawt pangngai lo
  • String discharge thil thleng leh a hun chhung

Cell Level-ah harsatna hriat chian zawk

  • Cell pakhat emaw block pakhatah float voltage pangngai lo a awm
  • Internal resistance emaw impedance emaw tihpun
  • Battery pakhat chu a kianga battery aiin a lum zawk
  • String chhunga voltage inthlauhna
  • Battery chak lo tak discharge laiin voltage hniam tak a thlen hma
  • Connection loose emaw, chhe tawh emaw
  • Battery sensor pakhat zel nena inbiakpawhna hloh

Battery pakhatin a capacity awm leh service life la awm chu tehna pakhat mah a finfiah lo. Voltage, resistance, temperature leh current te hi historical trends te, inspection te, manufacturer recommendation te, leh capacity testing dik tak te nen endik tur a ni.

Engvangin nge Critical Power Systems hian Level pahnih hi a mamawh tlangpui

Cell-level leh string-level monitoring hi technology inelna anga ngaih tur a ni lo. Stationary battery monitoring architecture kimchang tak chuan a tlangpuiin a inzawm khawm thin.

Sensor pakhat zel hian battery-level voltage, resistance leh temperature te a teh thin. String device hian total voltage leh current a teh thin. Controller emaw gateway emaw hian data a khawlkhawm a, alarm logic a hmang a, historical record a dahkhawm a, local interface emaw centralized management platform emaw ah information a transfer bawk.

He architecture inzawmkhawm hian operator-te chu zawhna hrang hrang pahnih chhan theihna a pe a, chungte chu

  • Battery system ah hian eng thil nge thleng? String-level voltage leh current hian operating event zawng zawng a tarlang a.
  • Eng battery nge ngaihven ngai? Cell-level data hian battery pangngai lo leh a trend a hriat theih.
DFUN BMS dashboard-ah string-level leh battery voltage pakhat zel data a lang
DFUN BMS dashboard-ah string-level leh individual battery voltage data tarlanna a ni

Engtikah nge String-Level Monitoring hi a remchan?

String-level monitoring hi ngaihtuah theih a ni a, chu chu:

  • Battery dahna hi a te a, kut hmanga enfiah a awlsam hle
  • Protected load hian a chhiat avanga a rah chhuah a hniam zawk
  • A mamawh ber chu charge, discharge, leh string condition zawng zawng hriatchhuah a ni
  • Trained personnel te chuan mimal battery tehna an ti fo thei a ni
  • He project hi initial monitoring phase a ni a, nakin lawka tihpun dan tur ruahmanna mumal tak a awm bawk

Heng application-ah pawh hian periodic cell emaw block emaw measurement hi a ngai reng a ni. String monitoring hi string chhunga battery zawng zawng a hrisel tih nemnghehna anga ngaih tur a ni lo.

Cell-level monitoring hi a hlu hle a, chu chu:

  • Battery hian data center, substation, telecom network, rel kawng, airport, hospital, oil leh gas facility emaw, critical load dang emaw a support thei a ni
  • Installation ah hian string sei tak tak emaw parallel string tam tak emaw a awm a
  • Site-te chu mihring awm lohna, hla tak, tlawh man to tak a ni
  • Maintenance team te hian alarm nena inzawm battery dik tak chu an hriat chian a ngai a ni
  • Condition-based maintenance atan hian historical data a ngai a ni
  • Battery temperature leh internal resistance trend te hi khaikhin a ngai a ni
  • Operator hian site hrang hrangah centralized monitoring a mamawh a ni
  • Discharge tak tak emaw, discharge scheduled emaw laia battery performance chu record tur a ni

Cell-level monitoring hlutna hi battery installation-a criticality, scale, remoteness leh maintenance complexity te nen a sang chho zel a ni.

Dilna Entirna

Data Center leh UPS System hrang hrang te

String voltage leh current hian overall charging emaw discharge event chu a nemnghet a, cell-level data erawh chuan UPS runtime a nghawng hmain 12V block chak lo tak chu a zawng chhuak thei thung. DCIM emaw network management platform nena inzawmna chuan alarm leh report te chu a centralize thei a ni.

Power Utilities leh Substation hrang hrang te

Substation DC system-ah hian 2V lead-acid emaw 1.2V Ni-Cd cell tam tak a awm thei. Cell-level monitoring hian bank pumpuiah voltage leh temperature tehkhin a pui a, string-level current leh voltage hian charger leh DC system awm dan a lantir thung.

Telecommunication lam a ni

Remote 48V telecom site-te chuan cell-level fault localization hmangin hlawkna an hmu a, a chhan chu maintenance visit hi a man a to hle. String measurement hian charge leh discharge event-ah visibility a pe a, centralized software hian team-te chu eng site nge ngaihven ngai tih dah pawimawh turin a pui bawk.

Transportation leh Industrial Facilities te a awm bawk

Rel, airport, oil leh gas, leh thil siamna hmunte hian distributed battery system hrang hrang an hmang thei a ni. Level pahnih inzawmkhawm hian maintenance team-te chu battery pakhat zel hmuh theihna hloh lovin system-wide events enkawl turin a pui a ni.

Stationary battery room-ah DFUN cell-level monitoring system hmanga thuam a ni
Stationary battery room-ah DFUN cell-level monitoring system hmanga thuam a ni

Monitoring hian Capacity Testing a thlak lo

Cell-level monitoring hian hmuh theihna a ti tha a, mahse battery bank pum pui hman theih ampere-hour capacity chu direct-in a teh lo. Internal resistance leh voltage trends hian battery chhui chian ngai te hriatchhuahna kawngah a pui thei a, discharge test dik taka neih chuan battery hian condition ruat sa hnuaia load ruat sa a support theih dan a finfiah bawk.

Thil pawimawh tak takte tan chuan maintenance strategy hian monitoring chhunzawm zel, mit hmuha enfiah, connection check, manufacturer kaihhruaina, leh scheduled capacity verification te a huam tel tur a ni.

Monitoring Architecture dik tak thlan dan

System i thlan hmain a hnuaia project information te hi la khawm hmasa phawt ang che:

  1. Battery chhiat avanga hman dan leh a rah chhuah tur hriat chian.
  2. Battery chemistry, nominal voltage, capacity, leh siamtute chu finfiah rawh.
  3. String tina cell emaw block emaw awm zat record rawh.
  4. String awm zat leh parallel-a an thawh leh thawh loh record rawh.
  5. Cell-level leh string-level parameter mamawh turte chu sawifiah rawh.
  6. Alarm dawngtu tur leh chhanna hun mamawh tur sawifiah rawh.
  7. Integration mamawh Modbus, SNMP, MQTT, emaw IEC 61850 te chu nemnghet rawh.
  8. System hian nakin lawka expansion emaw site tam tak emaw a support tur em tih chu ruat rawh.

Critical power installation tam tak tan chuan design tangkai ber chu cell-level emaw string-level monitoring emaw a ni lo. Integrated system a ni a, a pahnih hian a hmang vek a ni.

Zawhna Zawh fo thin

Cell-level battery monitoring hi string-level monitoring aiin a tha zawk em?

Cell-level monitoring hian fault detection leh localization chipchiar zawk a pe a, mahse battery kalphung zawng zawng hriatthiamna atan string-level voltage leh current chu a pawimawh reng a ni. Critical system te hian level pahnih hi an inzawm khawm hian hlawkna an hmu tlangpui.

String voltage hian battery chak lo a hriat theih em?

Rin tlak a ni lo. Battery pakhat a dik loh laiin total string voltage chu beisei angin a awm thei. Mimal voltage, resistance, temperature leh discharge trend te hian battery chak lo awmna hmun hriat theihna tur information tangkai zawk a pe a ni.

Cell-level battery enkawlna hian eng nge a teh?

Battery chi leh system a zirin mimal voltage, internal resistance emaw impedance, temperature, connection resistance, electrolyte level, leh leakage condition te a teh thei a ni.

Battery tin hian anmahni sensor an mamawh em?

Cell-level system tam takah chuan cell emaw block emaw pakhatah sensor pakhat an hmang thin. Architecture dangte chuan multi-channel measurement module an hmang thei bawk. Design dik tak chu battery voltage, chemistry, battery awm zat leh parameter mamawh danah a innghat a ni.

Cell-level monitoring hian battery runtime dik tak a hrilhfiah thei em?

Monitored parameter pakhat mah hian runtime dik tak a tichiang thei lo. Monitoring hian operating condition leh degradation trends a hriat theih a, chutih laiin available capacity emaw runtime emaw chu discharge test dik tak hmanga finfiah tur a ni.

Cell-level data hi SCADA emaw DCIM emaw nen a inzawm thei ang em?

Awle. Controller emaw gateway emaw hian battery leh string data pakhat zel a aggregate thei a, supported protocol hmangin measurement leh alarm thlan bikte chu a transfer thei bawk. System design laiin compatibility leh data-point list mamawh chu confirm tur a ni.

DFUN hmangin Battery Monitoring Solution kimchang tak siam rawh

DFUN hian data center, power utilities, telecommunication, transportation, leh industrial critical power system te tan cell-level leh string-level battery monitoring solution a pe a ni. Configuration awmsa te hian battery sensor pakhat zel, string tehna, historical trends, configurable alarm, centralized management, leh common industrial protocol nena inzawmna te a support a ni.

I battery chemistry, cell emaw block voltage, battery awm zat, string awm zat, leh communication protocol mamawh chu DFUN hnenah thawn rawh. Kan engineering team hian i application nena inmil monitoring architecture siam turin an pui thei a ni.

Battery Assessment a thlawna neih theih a ni

Kan BMS engineer zinga pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah biak theih a ni

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni