In » CHANCHINTHAR » Industry chanchin thar . » IEC 61850: DFUN battery monitoring system hmanga power management tha tak pek

IEC 61850: DFUN battery monitoring system hmanga power management tha tak pek theihna tur

A ziaktu: Site Editor Thuchhuah Hun: 2024-12-19 A chhuahna hmun: Hmun

zawhna zawt rawh .

Facebook Sharing button a awm bawk.
Twitter atanga Sharing button a awm bawk.
Line Sharing button a awm bawk.
WeChat hmanga Sharing tih a ni.
LinkedIn Sharing button a awm bawk.
Pinterest hmanga Sharing tih a ni.
WhatsApp Sharing button 1000 a awm bawk.
ShareHe Sharing button hi a awm em?

IEC 61850 DFUN battery enkawlna system a awm bawk.


Tunlai industrial automation-ah chuan, a bik takin power sector-ah chuan IEC 61850 chu khawvel pum huapa pawm standard-ah a lo lang chhuak ta a ni. Framework kimchang tak angin, IEC 61850 hian substation chhunga intelligent electronic devices (IEDs) zingah communication protocols a standardize a, system integration tha tak a siam thei a ni. Khawvel puma power system-ah te, a bik takin renewable energy sources thli leh ni chakna bakah microgrid management-ah te hman lar tak a ni a, he protocol hian device leh system hrang hrangte inkara inzawmna nghet tak a siam thei a ni.


IEC 61850 hi eng nge ni?


IEC 61850 hi substation automation atana ruahman bik communication protocol a ni a, thil siamtu hrang hrang atanga device hrang hrangte inzawmna tihchak leh power system te efficiency leh rintlakna tihpun a tum a ni. Real-time monitoring, control, leh protection functions a pui a, renewable energy field-ah te thli leh ni chakna ang chi te, traditional power network automation-ah te pawh nasa takin a hmang a ni. IEC 61850-a thil pawimawh tak pakhat chu MMS (Manufacturing Message Specification) protocol hmanga device hrang hrangte inkara non-real-time data exchange a support a, configuration settings, event logs, leh diagnostic information te a siam thei a ni.

Digitalization leh intelligent technology a lo chhuah takah chuan IEC 61850 standard kalpui a nih tak avangin a pawimawh zual ta hle a ni. Device hrang hrang inkara inbiakpawhna rang leh real-time data insem theihna hmangin, industrial automation system-te chu efficiency leh reliability level sang zawk neih theihna turin a pui a ni.


DFUN Battery Monitoring System: IEC 61850 support hmanga power enkawlna fing tak khalh


DFUN PBMS9000 leh PBMS9000Pro battery monitoring system hian power system automation atan technical support tha tak a pe a ni. Intelligent battery monitoring system hi IEC 61850 protocol nen a inmil mai bakah device leh system hrang hrang nena inzawm tlat a ni a, real-time data exchange leh efficient taka hman a ni. Microgrids emaw, smart grids emaw, traditional power system emaw atan pawh nise, DFUN battery monitoring system hian battery monitoring dik tak, management, leh optimization hmangin system stability leh reliability a tichiang a ni.


DFUN PBMS9000Pro battery enkawlna system a awm bawk.


He system hian inbiakpawhna protocol hrang hrang a thlawp a, chung zingah chuan IEC 61850 , battery management leh substation hmanrua dangte thawhhona tha zawk a awm thei a ni. He system hian battery charge leh discharge state te chu real time-in a enkawl a, battery health report kimchang tak a pe chhuak a, battery lifespan tihchangtlun nan intelligent algorithms a hmang a, load condition inthlak chak tak hnuaiah pawh a thawk tha thei hle.


IEDSCOUT tool chhunga data model leh activity enfiah theihna DFUN IED .

chhunga data model leh activity enfiah theihna DFUN IED . IEDSCOUT tool


Product a thatna te .


  • Data inthleng tangkai dan: IEC 61850 protocol thlawpna hian battery monitoring system leh substation device dangte inkara inbiakpawhna rang leh rintlak a siam thei a ni.

  • Real-time monitoring and control: Integrated real-time data sharing hmang hian power manager te chuan anomalies te chu rang takin an chhang let thei a, system rintlakna a ti sang thei a ni.

  • Flexible scalability: Thli leh ni chakna ang chi renewable energy system-a automation mamawhna a pui a, microgrid project-ah pawh a pui bawk.

  • Battery life rei zawk: Battery lifespan leh operational efficiency a ti sang a, balancing leh health management dik tak hmangin.


DFGW1000 (IEC 61850 Protocol Converter) a awm bawk.


DFUN atanga highlight dang, DFGW1000 , chu power utility building leh substation hrang hrang atana siam bik a ni a, protocol conversion leh integration atana support tha tak a pe a ni:


DFGW1000 (IEC 61850 Protocol Converter) a awm bawk.


  • High-performance hardware: Quad-core CortexTM-A53 processor, 1GB RAM, 8GB storage, gigabit ethernet ports, leh RS485 serial port te hmanga siam a ni.

  • Wide environmental adaptability:  -15°C atanga +60°C thlenga temperature-ah a thawk tha hle a, industrial environment complex tak takte mamawh phuhrukna a ni.

  • Protocol Conversion capability: IEC 61850 chu protocol dang ah efficient takin a convert a, device hrang hrang inkara seamless interconnection a siam thei.

  • Broad Applications: Power monitoring atanga battery management thlengin, industrial automation mamawh hrang hrangah theihtawp chhuah lovin a inzawm khawm a ni.


Tawpna


Industrial automation a lo thang zel a, chanvo chu a pawimawh zual zel a ni. IEC 61850 protocol power sector- a a integration capability sang tak hian DFUN battery monitoring system- power system hrang hrang tan solution fing zawk leh rintlak zawk a pe a, hei hian energy management digital transformation a ti chak zawk a ni. Thli chakna emaw, ni chakna emaw, microgrid system emaw-a hman pawh ni se, he system hian battery enkawlna kawng ṭha tak, him leh rintlak tak a pe chhuak a ni.



Kan inzawmna .

Product category 10 a awm bawk.

Quick Links .

Kan rawn biak theih reng e

   +86-15919182362==
  +86-756-6123188 ah a awm.
 chuan .  +86-15919182362= a ni.

A rilru a buai em em a, a rilru a hah em em 2023 bawk a. DFUN (Zhuhai) Co., Ltd. Thuneihna zawng zawng a nei. Privacy policy 1.1. | Sitemap 100 a ni.