A ziaktu: Site Editor Thuchhuah Hun: 2024-12-19 A chhuahna hmun: Hmun
Tunlai industrial automation-ah chuan, a bik takin power sector-ah chuan IEC 61850 chu khawvel pum huapa pawm standard-ah a lo lang chhuak ta a ni. Framework kimchang tak angin, IEC 61850 hian substation chhunga intelligent electronic devices (IEDs) zingah communication protocols a standardize a, system integration tha tak a siam thei a ni. Khawvel puma power system-ah te, a bik takin renewable energy sources thli leh ni chakna bakah microgrid management-ah te hman lar tak a ni a, he protocol hian device leh system hrang hrangte inkara inzawmna nghet tak a siam thei a ni.
IEC 61850 hi substation automation atana ruahman bik communication protocol a ni a, thil siamtu hrang hrang atanga device hrang hrangte inzawmna tihchak leh power system te efficiency leh rintlakna tihpun a tum a ni. Real-time monitoring, control, leh protection functions a pui a, renewable energy field-ah te thli leh ni chakna ang chi te, traditional power network automation-ah te pawh nasa takin a hmang a ni. IEC 61850-a thil pawimawh tak pakhat chu MMS (Manufacturing Message Specification) protocol hmanga device hrang hrangte inkara non-real-time data exchange a support a, configuration settings, event logs, leh diagnostic information te a siam thei a ni.
Digitalization leh intelligent technology a lo chhuah takah chuan IEC 61850 standard kalpui a nih tak avangin a pawimawh zual ta hle a ni. Device hrang hrang inkara inbiakpawhna rang leh real-time data insem theihna hmangin, industrial automation system-te chu efficiency leh reliability level sang zawk neih theihna turin a pui a ni.
DFUN PBMS9000 leh PBMS9000Pro battery monitoring system hian power system automation atan technical support tha tak a pe a ni. Intelligent battery monitoring system hi IEC 61850 protocol nen a inmil mai bakah device leh system hrang hrang nena inzawm tlat a ni a, real-time data exchange leh efficient taka hman a ni. Microgrids emaw, smart grids emaw, traditional power system emaw atan pawh nise, DFUN battery monitoring system hian battery monitoring dik tak, management, leh optimization hmangin system stability leh reliability a tichiang a ni.
He system hian inbiakpawhna protocol hrang hrang a thlawp a, chung zingah chuan IEC 61850 , battery management leh substation hmanrua dangte thawhhona tha zawk a awm thei a ni. He system hian battery charge leh discharge state te chu real time-in a enkawl a, battery health report kimchang tak a pe chhuak a, battery lifespan tihchangtlun nan intelligent algorithms a hmang a, load condition inthlak chak tak hnuaiah pawh a thawk tha thei hle.
chhunga data model leh activity enfiah theihna DFUN IED . IEDSCOUT tool
Data inthleng tangkai dan: IEC 61850 protocol thlawpna hian battery monitoring system leh substation device dangte inkara inbiakpawhna rang leh rintlak a siam thei a ni.
Real-time monitoring and control: Integrated real-time data sharing hmang hian power manager te chuan anomalies te chu rang takin an chhang let thei a, system rintlakna a ti sang thei a ni.
Flexible scalability: Thli leh ni chakna ang chi renewable energy system-a automation mamawhna a pui a, microgrid project-ah pawh a pui bawk.
Battery life rei zawk: Battery lifespan leh operational efficiency a ti sang a, balancing leh health management dik tak hmangin.
DFUN atanga highlight dang, DFGW1000 , chu power utility building leh substation hrang hrang atana siam bik a ni a, protocol conversion leh integration atana support tha tak a pe a ni:
High-performance hardware: Quad-core CortexTM-A53 processor, 1GB RAM, 8GB storage, gigabit ethernet ports, leh RS485 serial port te hmanga siam a ni.
Wide environmental adaptability: -15°C atanga +60°C thlenga temperature-ah a thawk tha hle a, industrial environment complex tak takte mamawh phuhrukna a ni.
Protocol Conversion capability: IEC 61850 chu protocol dang ah efficient takin a convert a, device hrang hrang inkara seamless interconnection a siam thei.
Broad Applications: Power monitoring atanga battery management thlengin, industrial automation mamawh hrang hrangah theihtawp chhuah lovin a inzawm khawm a ni.
Industrial automation a lo thang zel a, chanvo chu a pawimawh zual zel a ni. IEC 61850 protocol power sector- a a integration capability sang tak hian DFUN battery monitoring system- power system hrang hrang tan solution fing zawk leh rintlak zawk a pe a, hei hian energy management digital transformation a ti chak zawk a ni. Thli chakna emaw, ni chakna emaw, microgrid system emaw-a hman pawh ni se, he system hian battery enkawlna kawng ṭha tak, him leh rintlak tak a pe chhuak a ni.
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .