Wɔ beae a ɛkorɔn mita 4,500 wɔ Ngari, Tibet , awɔw bere mu hyew so tew kodu –18°C , bere a oxygen dodow so tew kodu nea ɛwɔ po so no mu 50% pɛ .
Mfe pii no, batere ahoɔden a wɔsɔ hwɛ daa wɔ mmeae nketewa a ɛwɔ ɔmantam yi mu no kyerɛ sɛ mfiridwumayɛfo de nnwinnade a emu yɛ duru twaa mmepɔw a sukyerɛmma akata so, na wotuu kwan bɛboro kilomita 300 kɔhwɛɛ mu pɛnkoro. Nsaano sɔhwɛ biara bo boro USD 15,000, a data mfomso a ɛkɔ soro kodu 5% , na mpo ɛde asiane bae sɛ backup power bedi huammɔ esiane adwemmɔne nti.


Ɛnnɛ, wɔasakra asɛnnennen yi titiriw.
With DFUN’s remote online battery capacity testing solution , afei adwumayɛfo betumi awie battery akwahosan nhwehwɛmu a edi mũ denam klike biako so , fi kilomita ɔhaha pii — a akwantu, ntwitwiridii, anaasɛ nsaano nhama nni mu. Saa nkɔso yi kyerɛ anammɔn titiriw a wɔatu wɔ anyinam ahoɔden nhyehyɛe a nyansa wom a wɔde di dwuma mu , titiriw wɔ mmeae a ɛyɛ hu te sɛ Tibet Asasetaw no.

Wɔ mmeae te sɛ Ngari no, atetesɛm mu batere sɔhwɛ hyia akwanside abiɛsa a ɛho hia:
Mpɛn pii no, wɔde bɛboro kilomita 300 na ɛda substations ntam , na ɛma akwantu, nnwinnade a wɔde fa nneɛma, ne nnipa a wɔde di dwuma no bo yɛ den yiye.
Oxygen a ɛba fam ne awɔw a ano yɛ den ma ɛyɛ mmerɛw sɛ obi bɛyare wɔ mmeae a ɛkorɔn, awɔw bɛtɔ, na akwanhyia a ɛba wɔ adwumayɛ mu bere a wɔreyɛ adwuma wɔ beae hɔ no.
Manual wiring ne data recording yɛ mmerɛw wɔ ɔhyew a ɛba fam mu, mpɛn pii no ɛhwehwɛ sɛ mfiridwumayɛfo pii na ɛde nea wontumi mfa ho nto so ba — ɛka backup power ahotoso tẽẽ.
Saa nsɛnnennen yi si nnwuma mu nokwasɛm a ɛrenya nkɔanim so dua: nsaano batere sɔhwɛ nyɛ nea ɛtra hɔ daa bio mma nnɛyi anyinam ahoɔden nhama.

Wɔde mfeɛ pii a wɔanya wɔ battery monitoring systems (BMS) ne DC power infrastructure , DFUN yɛɛ akyirikyiri, intanɛt, automated battery tumi sɔhwɛ ano aduru a wɔayɛ ama mmeae a ɛyɛ den ne battery bank akɛse.
Ɔhyew nhyehyɛe a wɔama anya nkɔso ne plateau-grade insulation nneɛma ma ɔhyew a wɔsɛe no yiye 50% , san de insulation adwumayɛ kɔ bɛboro 90% wɔ mmeae a ɛba fam.
Ɔhyew a ɛkɔ anim akatua ne ankasa-calibration algorithms ma susuw pɛpɛɛpɛyɛ wɔ ±0.5% , a wɔde toto laboratory gyinapɛn ahorow ho.
Dual-link nkitahodi ne nyansa a wɔde di dwuma hwɛ hu sɛ nnɔnhwerew 8–10 a wontumi ntwitware discharge testing , mpo wɔ electromagnetic mmeae a ɛyɛ den.
Wɔ adwumayɛ ankasa mu no, nhyehyɛe no nyaa zero on-site commissioning , nkonimdi wiee akyirikyiri tumi sɔhwɛ ahorow 23 a ɛtoatoa so wɔ –18°C tebea horow mu — bere a wohuu sɛnkyerɛnne ahorow a edi kan a ɛkyerɛ sɛ emu ahoɔden a ɛnteɛ wɔ battery hama biako mu nnafua 15 ansa na ɛreba.



DFUN ano aduru no ka akyirikyiri battery monitoring , capacity testing , ne cell-level analysis bom yɛ nyansa platform biako.
Mfaso atitiriw a ɛwɔ so no bi ne:
Bere ankasa a wɔhwɛ voltage, emu resistance, ɔhyew, SOC, ne SOH
Mfomso a wohu ntɛm wɔ ankorankoro nkwammoaa gyinabea, a esiw ɔhyew guankɔbea ano
Grid-connected energy feedback , a ɛsan de ahoɔden a wɔtow gu no kɔ grid no mu na ɛtew carbon a wɔtow gu no so
Remote centralized management , a ɛtew akwantu, adwumayɛfo ka, ne ahobammɔ ho asiane so kɛse
Ɛdenam battery ahoɔden sɔhwɛ a wɔde ka bom ne Battery Management System a ɛkɔ anim so no , DFUN boa substations ne power utilities ma wofi reactive maintenance so kɔ nkɔmhyɛ, data-driven adwumayɛ so.

DFUN akyirikyiri batere ahoɔden sɔhwɛ ano aduru a wɔde adi dwuma yiye wɔ Tibet no hyɛ nsakrae a ɛkɔ nyansa, dijitaal, ne grid adwumayɛ a ɛkɔ so daa no .
agyirae Sɛ ɛnyɛ mfiridwuma mu nkɔso, ɛkyerɛ sɛnea batere a wɔhwɛ so yiye ne BMS mfiridwuma betumi abɔ ahoɔden nhyehyɛe a ɛho hia ho ban — wɔ wiase mmeae a ɛkorɔn sen biara mpo.
Efi substations ne telecom sites so kosi data centers ne industrial power systems so no, DFUN kɔ so de battery management solutions a wotumi de ho to so a ɛma power systems yɛ nea ahobammɔ wom, ɛyɛ adwuma yiye, na ɛyɛ krado daakye ma.

Sua pii fa DFUN battery monitoring ne akyirikyiri tumi sɔhwɛ ano aduru ho wɔ www.dfuntech.com .
Czech metro ahobammɔ a wɔde DFUN battery hwɛ nhyehyɛe so tumi .
Dfun BMS: Indonesia data mmeae a ahoɔden wom a ahoɔden a ɛyɛ den wom .
Nabiax Data Center Battery Monitoring System Project Nhwehwɛmu .
Nsɛm a Wɔayɛ ho Nhwehwɛmu | Battery Monitoring System ma Ahoɔden Batere Foforo
August 15th-Malaysia Gyata data center adwuma no asɛm, EATON UPS, C&D batere
Nokware IDC Battery Monitoring System Dwumadie Nkyerɛkyerɛmu